Dynamic multicoil technique (DYNAMITE) MRI on human brain.

Saved in:
Bibliographic Details
Title: Dynamic multicoil technique (DYNAMITE) MRI on human brain.
Authors: Juchem, Christoph1,2 (AUTHOR) cwj2112@columbia.edu, Theilenberg, Sebastian1 (AUTHOR), Kumaragamage, Chathura3 (AUTHOR), Mullen, Michael4 (AUTHOR), DelaBarre, Lance4 (AUTHOR), Adriany, Gregor4 (AUTHOR), Brown, Peter B.3 (AUTHOR), McIntyre, Scott3 (AUTHOR), Nixon, Terence W.3 (AUTHOR), Garwood, Michael4 (AUTHOR), Graaf, Robin A.3 (AUTHOR)
Source: Magnetic Resonance in Medicine. Dec2020, Vol. 84 Issue 6, p2953-2963. 11p.
Subjects: Numerical integration, Magnetic fields
Abstract: Purpose: Spatial encoding for MRI is generally based on linear x, y, and z magnetic field gradients generated by a set of dedicated gradient coils. We recently introduced the dynamic multicoil technique (DYNAMITE) for B0 field control and demonstrated DYNAMITE MRI in a preclinical MR environment. In this study, we report the first realization of DYNAMITE MRI of the in vivo human head. Methods: Gradient fields for DYNAMITE MRI were generated with a 28‐channel multicoil hardware arranged in 4 rows of 7 coils on a cylindrical surface (length 359 mm, diameter 344 mm, maximum 5 A per coil). DYNAMITE MRIs of a resolution phantom and in vivo human heads were acquired with multislice gradient‐echo, multislice spin‐echo, and 3D gradient‐echo sequences. The resultant image fidelity was compared to that obtained with conventional gradient coil technology. Results: DYNAMITE field control enabled the realization of all imaging sequences with average gradient errors ≤ 1%. DYNAMITE MRI provided image quality and sensitivity comparable to conventional gradient technology without any obvious artifacts. Some minor geometric deformations were noticed primarily in the image periphery as the result of regional field imperfections. The imperfections can be readily approximated theoretically through numerical integration of the Biot‐Savart law and removed through image distortion correction. Conclusion: The first realization of DYNAMITE MRI of the in vivo human head has been presented. The obtained image fidelity is comparable to MRI with conventional gradient coils, paving the way for full‐fledged DYNAMITE MRI and B0 shim systems for human applications. [ABSTRACT FROM AUTHOR]
Copyright of Magnetic Resonance in Medicine is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Full text is not displayed to guests.
FullText Links:
  – Type: pdflink
Text:
  Availability: 1
Header DbId: egs
DbLabel: Engineering Source
An: 145719158
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Dynamic multicoil technique (DYNAMITE) MRI on human brain.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Juchem%2C+Christoph%22">Juchem, Christoph</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)<i> cwj2112@columbia.edu</i><br /><searchLink fieldCode="AR" term="%22Theilenberg%2C+Sebastian%22">Theilenberg, Sebastian</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Kumaragamage%2C+Chathura%22">Kumaragamage, Chathura</searchLink><relatesTo>3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Mullen%2C+Michael%22">Mullen, Michael</searchLink><relatesTo>4</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22DelaBarre%2C+Lance%22">DelaBarre, Lance</searchLink><relatesTo>4</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Adriany%2C+Gregor%22">Adriany, Gregor</searchLink><relatesTo>4</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Brown%2C+Peter+B%2E%22">Brown, Peter B.</searchLink><relatesTo>3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22McIntyre%2C+Scott%22">McIntyre, Scott</searchLink><relatesTo>3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Nixon%2C+Terence+W%2E%22">Nixon, Terence W.</searchLink><relatesTo>3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Garwood%2C+Michael%22">Garwood, Michael</searchLink><relatesTo>4</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Graaf%2C+Robin+A%2E%22">Graaf, Robin A.</searchLink><relatesTo>3</relatesTo> (AUTHOR)
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Magnetic+Resonance+in+Medicine%22">Magnetic Resonance in Medicine</searchLink>. Dec2020, Vol. 84 Issue 6, p2953-2963. 11p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Numerical+integration%22">Numerical integration</searchLink><br /><searchLink fieldCode="DE" term="%22Magnetic+fields%22">Magnetic fields</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Purpose: Spatial encoding for MRI is generally based on linear x, y, and z magnetic field gradients generated by a set of dedicated gradient coils. We recently introduced the dynamic multicoil technique (DYNAMITE) for B0 field control and demonstrated DYNAMITE MRI in a preclinical MR environment. In this study, we report the first realization of DYNAMITE MRI of the in vivo human head. Methods: Gradient fields for DYNAMITE MRI were generated with a 28‐channel multicoil hardware arranged in 4 rows of 7 coils on a cylindrical surface (length 359 mm, diameter 344 mm, maximum 5 A per coil). DYNAMITE MRIs of a resolution phantom and in vivo human heads were acquired with multislice gradient‐echo, multislice spin‐echo, and 3D gradient‐echo sequences. The resultant image fidelity was compared to that obtained with conventional gradient coil technology. Results: DYNAMITE field control enabled the realization of all imaging sequences with average gradient errors ≤ 1%. DYNAMITE MRI provided image quality and sensitivity comparable to conventional gradient technology without any obvious artifacts. Some minor geometric deformations were noticed primarily in the image periphery as the result of regional field imperfections. The imperfections can be readily approximated theoretically through numerical integration of the Biot‐Savart law and removed through image distortion correction. Conclusion: The first realization of DYNAMITE MRI of the in vivo human head has been presented. The obtained image fidelity is comparable to MRI with conventional gradient coils, paving the way for full‐fledged DYNAMITE MRI and B0 shim systems for human applications. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Magnetic Resonance in Medicine is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=145719158
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1002/mrm.28323
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 11
        StartPage: 2953
    Subjects:
      – SubjectFull: Numerical integration
        Type: general
      – SubjectFull: Magnetic fields
        Type: general
    Titles:
      – TitleFull: Dynamic multicoil technique (DYNAMITE) MRI on human brain.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Juchem, Christoph
      – PersonEntity:
          Name:
            NameFull: Theilenberg, Sebastian
      – PersonEntity:
          Name:
            NameFull: Kumaragamage, Chathura
      – PersonEntity:
          Name:
            NameFull: Mullen, Michael
      – PersonEntity:
          Name:
            NameFull: DelaBarre, Lance
      – PersonEntity:
          Name:
            NameFull: Adriany, Gregor
      – PersonEntity:
          Name:
            NameFull: Brown, Peter B.
      – PersonEntity:
          Name:
            NameFull: McIntyre, Scott
      – PersonEntity:
          Name:
            NameFull: Nixon, Terence W.
      – PersonEntity:
          Name:
            NameFull: Garwood, Michael
      – PersonEntity:
          Name:
            NameFull: Graaf, Robin A.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 12
              Text: Dec2020
              Type: published
              Y: 2020
          Identifiers:
            – Type: issn-print
              Value: 07403194
          Numbering:
            – Type: volume
              Value: 84
            – Type: issue
              Value: 6
          Titles:
            – TitleFull: Magnetic Resonance in Medicine
              Type: main
ResultId 1