Performance evaluation of a utility-scale dual-technology photovoltaic power plant at the Shagaya Renewable Energy Park in Kuwait.

Saved in:
Bibliographic Details
Title: Performance evaluation of a utility-scale dual-technology photovoltaic power plant at the Shagaya Renewable Energy Park in Kuwait.
Authors: AL-Rasheedi, Majed1 (AUTHOR) mrashedi@kisr.edu.kw, Gueymard, Christian A.2 (AUTHOR), Al-Khayat, Mohammad1 (AUTHOR), Ismail, Alaa1 (AUTHOR), Lee, Jared A.3 (AUTHOR), Al-Duaj, Hamad1 (AUTHOR)
Source: Renewable & Sustainable Energy Reviews. Nov2020, Vol. 133, pN.PAG-N.PAG. 1p.
Subjects: Photovoltaic power systems, Building-integrated photovoltaic systems, Dust storms, Temperature effect
Geographic Terms: Kuwait
Abstract: This study presents the actual monitoring data and performance analysis results obtained from the 11.15-MW grid-connected Shagaya Photovoltaic Park, Kuwait (latitude 29.2°N, longitude 47.04°W). The plant was specifically built to compare two PV technologies: a Thin-Film (TF) installation of 5.5 MW and a Polycrystalline (PC) silicon installation of 5.6 MW. The plant has been designed as a pilot testbed to evaluate the performance of different grid-tied PV technologies under a hot desert environment. A 25-month monitoring period has provided important information that will be used to prepare the design of upcoming GW-size PV projects at Shagaya. Performance parameters of the PV system evaluated here include: final yield, reference yield, array yield, system losses, array capture losses, cell temperature losses, PV module efficiency, system efficiency, inverter efficiency, performance ratio, and capacity factor. Comparison between the TF and PC PV subsystems reveals no significant difference between the two technologies regarding annual reference yields (1805 kWh / kW for TF and 1810 kWh / kW for PC), performance ratios (80.0% for TF and 80.2% for PC), or system losses (20.04% for TF and 19.81% for PC). The PC panels are affected by slightly higher module capture losses due to their higher negative temperature coefficient. It is found, most importantly, that the two PV subsystems have very similar performance behavior when they have similar capacity and operate under the same Shagaya desert environment with the same stringent operational and maintenance strategies. One disadvantage of the TF subsystem, however, is that it requires 18.5% more land area than the PC subsystem to match the installed capacity. The soiling of panels is substantial and requires monthly cleaning with water, which is scarce in a desert environment. A smaller total panel area for a similar power output could constitute a significant economic advantage for the PC technology under such conditions. • The performance of Shagaya Photovoltaic park after two years' operation is presented. • Monitoring soiling is essential at photovoltaic plants located in high soiling areas. • Sudden dust storms can cause an instantaneous 30% drop in the photovoltaic power output. • Temperature effect on Thin-film and Polycrystalline photovoltaic performance are calculated. • Performance ratio, yields, and system losses of different photovoltaic technologies investigated. [ABSTRACT FROM AUTHOR]
Copyright of Renewable & Sustainable Energy Reviews is the property of Pergamon Press - An Imprint of Elsevier Science and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 146346186
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Performance evaluation of a utility-scale dual-technology photovoltaic power plant at the Shagaya Renewable Energy Park in Kuwait.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22AL-Rasheedi%2C+Majed%22">AL-Rasheedi, Majed</searchLink><relatesTo>1</relatesTo> (AUTHOR)<i> mrashedi@kisr.edu.kw</i><br /><searchLink fieldCode="AR" term="%22Gueymard%2C+Christian+A%2E%22">Gueymard, Christian A.</searchLink><relatesTo>2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Al-Khayat%2C+Mohammad%22">Al-Khayat, Mohammad</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Ismail%2C+Alaa%22">Ismail, Alaa</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Lee%2C+Jared+A%2E%22">Lee, Jared A.</searchLink><relatesTo>3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Al-Duaj%2C+Hamad%22">Al-Duaj, Hamad</searchLink><relatesTo>1</relatesTo> (AUTHOR)
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Renewable+%26+Sustainable+Energy+Reviews%22">Renewable & Sustainable Energy Reviews</searchLink>. Nov2020, Vol. 133, pN.PAG-N.PAG. 1p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Photovoltaic+power+systems%22">Photovoltaic power systems</searchLink><br /><searchLink fieldCode="DE" term="%22Building-integrated+photovoltaic+systems%22">Building-integrated photovoltaic systems</searchLink><br /><searchLink fieldCode="DE" term="%22Dust+storms%22">Dust storms</searchLink><br /><searchLink fieldCode="DE" term="%22Temperature+effect%22">Temperature effect</searchLink>
– Name: SubjectGeographic
  Label: Geographic Terms
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Kuwait%22">Kuwait</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: This study presents the actual monitoring data and performance analysis results obtained from the 11.15-MW grid-connected Shagaya Photovoltaic Park, Kuwait (latitude 29.2°N, longitude 47.04°W). The plant was specifically built to compare two PV technologies: a Thin-Film (TF) installation of 5.5 MW and a Polycrystalline (PC) silicon installation of 5.6 MW. The plant has been designed as a pilot testbed to evaluate the performance of different grid-tied PV technologies under a hot desert environment. A 25-month monitoring period has provided important information that will be used to prepare the design of upcoming GW-size PV projects at Shagaya. Performance parameters of the PV system evaluated here include: final yield, reference yield, array yield, system losses, array capture losses, cell temperature losses, PV module efficiency, system efficiency, inverter efficiency, performance ratio, and capacity factor. Comparison between the TF and PC PV subsystems reveals no significant difference between the two technologies regarding annual reference yields (1805 kWh / kW for TF and 1810 kWh / kW for PC), performance ratios (80.0% for TF and 80.2% for PC), or system losses (20.04% for TF and 19.81% for PC). The PC panels are affected by slightly higher module capture losses due to their higher negative temperature coefficient. It is found, most importantly, that the two PV subsystems have very similar performance behavior when they have similar capacity and operate under the same Shagaya desert environment with the same stringent operational and maintenance strategies. One disadvantage of the TF subsystem, however, is that it requires 18.5% more land area than the PC subsystem to match the installed capacity. The soiling of panels is substantial and requires monthly cleaning with water, which is scarce in a desert environment. A smaller total panel area for a similar power output could constitute a significant economic advantage for the PC technology under such conditions. • The performance of Shagaya Photovoltaic park after two years' operation is presented. • Monitoring soiling is essential at photovoltaic plants located in high soiling areas. • Sudden dust storms can cause an instantaneous 30% drop in the photovoltaic power output. • Temperature effect on Thin-film and Polycrystalline photovoltaic performance are calculated. • Performance ratio, yields, and system losses of different photovoltaic technologies investigated. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Renewable & Sustainable Energy Reviews is the property of Pergamon Press - An Imprint of Elsevier Science and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=146346186
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1016/j.rser.2020.110139
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 1
        StartPage: N.PAG
    Subjects:
      – SubjectFull: Photovoltaic power systems
        Type: general
      – SubjectFull: Building-integrated photovoltaic systems
        Type: general
      – SubjectFull: Dust storms
        Type: general
      – SubjectFull: Temperature effect
        Type: general
      – SubjectFull: Kuwait
        Type: general
    Titles:
      – TitleFull: Performance evaluation of a utility-scale dual-technology photovoltaic power plant at the Shagaya Renewable Energy Park in Kuwait.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: AL-Rasheedi, Majed
      – PersonEntity:
          Name:
            NameFull: Gueymard, Christian A.
      – PersonEntity:
          Name:
            NameFull: Al-Khayat, Mohammad
      – PersonEntity:
          Name:
            NameFull: Ismail, Alaa
      – PersonEntity:
          Name:
            NameFull: Lee, Jared A.
      – PersonEntity:
          Name:
            NameFull: Al-Duaj, Hamad
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 11
              Text: Nov2020
              Type: published
              Y: 2020
          Identifiers:
            – Type: issn-print
              Value: 13640321
          Numbering:
            – Type: volume
              Value: 133
          Titles:
            – TitleFull: Renewable & Sustainable Energy Reviews
              Type: main
ResultId 1