Iodine quantification in limited angle tomography.
Saved in:
| Title: | Iodine quantification in limited angle tomography. |
|---|---|
| Authors: | Michielsen, Koen1 (AUTHOR), Rodríguez‐Ruiz, Alejandro1 (AUTHOR), Reiser, Ingrid2 (AUTHOR), Nagy, James G.3 (AUTHOR), Sechopoulos, Ioannis1,4 (AUTHOR) ioannis.sechopoulos@radboudumc.nl |
| Source: | Medical Physics. Oct2020, Vol. 47 Issue 10, p4906-4916. 11p. |
| Subjects: | Digital mammography, Magnetic resonance mammography, Convolutional neural networks, Breast, Tomosynthesis, Iodine, Tomography |
| Abstract: | Purpose: To develop and test the feasibility of a two‐pass iterative reconstruction algorithm with material decomposition designed to obtain quantitative iodine measurements in digital breast tomosynthesis. Methods: Contrast‐enhanced mammography has shown promise as a cost‐effective alternative to magnetic resonance imaging for imaging breast cancer, especially in dense breasts. However, one limitation is the poor quantification of iodine contrast since the true three‐dimensional lesion shape cannot be inferred from the two‐dimensional (2D) projection. Use of limited angle tomography can potentially overcome this limitation by segmenting the iodine map generated by the first‐pass reconstruction using a convolutional neural network, and using this segmentation to restrict the iodine distribution in the second pass of the reconstruction. To evaluate the performance of the algorithms, a set of 2D digital breast phantoms containing targets with varying iodine concentration was used. In each breast phantom, a single simulated lesion with a random size (4 to 8 mm) was placed in a random location within each phantom, with the iodine distribution defined as either homogeneous or rim‐enhanced and blood iodine concentration set between 1.4 and 5.6 mg/mL. Limited angle projection data of these phantoms were simulated for wide and narrow angle geometries, and the proposed reconstruction and segmentation algorithms were applied. Results: The median Dice similarity coefficient of the segmented masks was 0.975 for the wide angle data and 0.926 for the narrow angle data. Using these segmentations during the second reconstruction pass resulted in an improvement in the concentration estimates (mean estimated‐to‐true concentration ratio, before and after second pass: 48% to 73% for wide angle; 30% to 73% for narrow angle), and a reduction in the coefficient of variation of the estimates (55% to 27% for wide angle; 54% to 35% for narrow angle). Conclusion: We demonstrate that the proposed two‐pass reconstruction can potentially improve accuracy and precision of iodine quantification in contrast‐enhanced tomosynthesis. [ABSTRACT FROM AUTHOR] |
| Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
|
Full text is not displayed to guests.
Login for full access.
|
|
| FullText | Links: – Type: pdflink Text: Availability: 1 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 146607717 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Iodine quantification in limited angle tomography. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Michielsen%2C+Koen%22">Michielsen, Koen</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Rodríguez‐Ruiz%2C+Alejandro%22">Rodríguez‐Ruiz, Alejandro</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Reiser%2C+Ingrid%22">Reiser, Ingrid</searchLink><relatesTo>2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Nagy%2C+James+G%2E%22">Nagy, James G.</searchLink><relatesTo>3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Sechopoulos%2C+Ioannis%22">Sechopoulos, Ioannis</searchLink><relatesTo>1,4</relatesTo> (AUTHOR)<i> ioannis.sechopoulos@radboudumc.nl</i> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Medical+Physics%22">Medical Physics</searchLink>. Oct2020, Vol. 47 Issue 10, p4906-4916. 11p. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22Digital+mammography%22">Digital mammography</searchLink><br /><searchLink fieldCode="DE" term="%22Magnetic+resonance+mammography%22">Magnetic resonance mammography</searchLink><br /><searchLink fieldCode="DE" term="%22Convolutional+neural+networks%22">Convolutional neural networks</searchLink><br /><searchLink fieldCode="DE" term="%22Breast%22">Breast</searchLink><br /><searchLink fieldCode="DE" term="%22Tomosynthesis%22">Tomosynthesis</searchLink><br /><searchLink fieldCode="DE" term="%22Iodine%22">Iodine</searchLink><br /><searchLink fieldCode="DE" term="%22Tomography%22">Tomography</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: Purpose: To develop and test the feasibility of a two‐pass iterative reconstruction algorithm with material decomposition designed to obtain quantitative iodine measurements in digital breast tomosynthesis. Methods: Contrast‐enhanced mammography has shown promise as a cost‐effective alternative to magnetic resonance imaging for imaging breast cancer, especially in dense breasts. However, one limitation is the poor quantification of iodine contrast since the true three‐dimensional lesion shape cannot be inferred from the two‐dimensional (2D) projection. Use of limited angle tomography can potentially overcome this limitation by segmenting the iodine map generated by the first‐pass reconstruction using a convolutional neural network, and using this segmentation to restrict the iodine distribution in the second pass of the reconstruction. To evaluate the performance of the algorithms, a set of 2D digital breast phantoms containing targets with varying iodine concentration was used. In each breast phantom, a single simulated lesion with a random size (4 to 8 mm) was placed in a random location within each phantom, with the iodine distribution defined as either homogeneous or rim‐enhanced and blood iodine concentration set between 1.4 and 5.6 mg/mL. Limited angle projection data of these phantoms were simulated for wide and narrow angle geometries, and the proposed reconstruction and segmentation algorithms were applied. Results: The median Dice similarity coefficient of the segmented masks was 0.975 for the wide angle data and 0.926 for the narrow angle data. Using these segmentations during the second reconstruction pass resulted in an improvement in the concentration estimates (mean estimated‐to‐true concentration ratio, before and after second pass: 48% to 73% for wide angle; 30% to 73% for narrow angle), and a reduction in the coefficient of variation of the estimates (55% to 27% for wide angle; 54% to 35% for narrow angle). Conclusion: We demonstrate that the proposed two‐pass reconstruction can potentially improve accuracy and precision of iodine quantification in contrast‐enhanced tomosynthesis. [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=146607717 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1002/mp.14400 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 11 StartPage: 4906 Subjects: – SubjectFull: Digital mammography Type: general – SubjectFull: Magnetic resonance mammography Type: general – SubjectFull: Convolutional neural networks Type: general – SubjectFull: Breast Type: general – SubjectFull: Tomosynthesis Type: general – SubjectFull: Iodine Type: general – SubjectFull: Tomography Type: general Titles: – TitleFull: Iodine quantification in limited angle tomography. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Michielsen, Koen – PersonEntity: Name: NameFull: Rodríguez‐Ruiz, Alejandro – PersonEntity: Name: NameFull: Reiser, Ingrid – PersonEntity: Name: NameFull: Nagy, James G. – PersonEntity: Name: NameFull: Sechopoulos, Ioannis IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 10 Text: Oct2020 Type: published Y: 2020 Identifiers: – Type: issn-print Value: 00942405 Numbering: – Type: volume Value: 47 – Type: issue Value: 10 Titles: – TitleFull: Medical Physics Type: main |
| ResultId | 1 |