Diagnostic Performance of Ultrasound Computer-Aided Diagnosis Software Compared with That of Radiologists with Different Levels of Expertise for Thyroid Malignancy: A Multicenter Prospective Study.
Saved in:
| Title: | Diagnostic Performance of Ultrasound Computer-Aided Diagnosis Software Compared with That of Radiologists with Different Levels of Expertise for Thyroid Malignancy: A Multicenter Prospective Study. |
|---|---|
| Authors: | Ye, Feng-Ying1 (AUTHOR), Lyu, Guo-Rong1,2 (AUTHOR) lgr_feus@sina.com, Li, Shang-Qing2 (AUTHOR), You, Jian-Hong3 (AUTHOR), Wang, Kang-Jian4 (AUTHOR), Cai, Ming-Li5 (AUTHOR), Su, Qi-Chen1 (AUTHOR) |
| Source: | Ultrasound in Medicine & Biology. Jan2021, Vol. 47 Issue 1, p114-124. 11p. |
| Subjects: | Diagnostic ultrasonic imaging, Thyroid gland, Nodular disease, Radiologists, Thyroid nodules, Longitudinal method, Computer software, Research, Ultrasonic imaging, Thyroid gland tumors, Research methodology, Medical cooperation, Evaluation research, Comparative studies, Clinical competence, Computer-aided diagnosis, Medical specialties & specialists |
| Abstract: | The aim of the work described here was to evaluate the diagnostic performance of ultrasound thyroid computer-aided diagnosis (CAD) software. This multicenter prospective study included 494 patients (565 thyroid nodules) who underwent surgery or biopsy after ultrasonography at four hospitals from January 2019 to September 2019. The diagnostic performance metrics of different readers were calculated and compared with the pathologic results. The sensitivity of CAD was outstanding and was equivalent to that of a senior radiologist (90.51% vs. 88.47%, p > 0.05). The area under the curve of CAD was equivalent to that of a junior radiologist (0.748 vs. 0.739, p > 0.05). However, the specificity was only 49.63%, which was lower than those of the three radiologists (75.56%, 85.93% and 90.37% for the junior, intermediate and senior radiologists, respectively). The diagnostic performance of the junior radiologist was significantly improved with the aid of CAD (junior + CAD). The sensitivity and area under the curve of junior + CAD were improved from 72.20% to 89.93% and from 0.739 to 0.816, respectively (both p values <0.05), and the positive predictive value, negative predictive value and κ coefficient improved from 76.3% to 78.6%, 82.0% to 86.8% and 0.394 to 0.511, respectively. Though specificity slightly decreased from 75.56% to 73.33%, the difference was not statistically significant (p > 0.05). In general, the clinical application value of CAD is promising, and its instrumental value for junior radiologists is significant. [ABSTRACT FROM AUTHOR] |
| Copyright of Ultrasound in Medicine & Biology is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
| FullText | Text: Availability: 0 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 147116632 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Diagnostic Performance of Ultrasound Computer-Aided Diagnosis Software Compared with That of Radiologists with Different Levels of Expertise for Thyroid Malignancy: A Multicenter Prospective Study. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Ye%2C+Feng-Ying%22">Ye, Feng-Ying</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Lyu%2C+Guo-Rong%22">Lyu, Guo-Rong</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)<i> lgr_feus@sina.com</i><br /><searchLink fieldCode="AR" term="%22Li%2C+Shang-Qing%22">Li, Shang-Qing</searchLink><relatesTo>2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22You%2C+Jian-Hong%22">You, Jian-Hong</searchLink><relatesTo>3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Wang%2C+Kang-Jian%22">Wang, Kang-Jian</searchLink><relatesTo>4</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Cai%2C+Ming-Li%22">Cai, Ming-Li</searchLink><relatesTo>5</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Su%2C+Qi-Chen%22">Su, Qi-Chen</searchLink><relatesTo>1</relatesTo> (AUTHOR) – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Ultrasound+in+Medicine+%26+Biology%22">Ultrasound in Medicine & Biology</searchLink>. Jan2021, Vol. 47 Issue 1, p114-124. 11p. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22Diagnostic+ultrasonic+imaging%22">Diagnostic ultrasonic imaging</searchLink><br /><searchLink fieldCode="DE" term="%22Thyroid+gland%22">Thyroid gland</searchLink><br /><searchLink fieldCode="DE" term="%22Nodular+disease%22">Nodular disease</searchLink><br /><searchLink fieldCode="DE" term="%22Radiologists%22">Radiologists</searchLink><br /><searchLink fieldCode="DE" term="%22Thyroid+nodules%22">Thyroid nodules</searchLink><br /><searchLink fieldCode="DE" term="%22Longitudinal+method%22">Longitudinal method</searchLink><br /><searchLink fieldCode="DE" term="%22Computer+software%22">Computer software</searchLink><br /><searchLink fieldCode="DE" term="%22Research%22">Research</searchLink><br /><searchLink fieldCode="DE" term="%22Ultrasonic+imaging%22">Ultrasonic imaging</searchLink><br /><searchLink fieldCode="DE" term="%22Thyroid+gland+tumors%22">Thyroid gland tumors</searchLink><br /><searchLink fieldCode="DE" term="%22Research+methodology%22">Research methodology</searchLink><br /><searchLink fieldCode="DE" term="%22Medical+cooperation%22">Medical cooperation</searchLink><br /><searchLink fieldCode="DE" term="%22Evaluation+research%22">Evaluation research</searchLink><br /><searchLink fieldCode="DE" term="%22Comparative+studies%22">Comparative studies</searchLink><br /><searchLink fieldCode="DE" term="%22Clinical+competence%22">Clinical competence</searchLink><br /><searchLink fieldCode="DE" term="%22Computer-aided+diagnosis%22">Computer-aided diagnosis</searchLink><br /><searchLink fieldCode="DE" term="%22Medical+specialties+%26+specialists%22">Medical specialties & specialists</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: The aim of the work described here was to evaluate the diagnostic performance of ultrasound thyroid computer-aided diagnosis (CAD) software. This multicenter prospective study included 494 patients (565 thyroid nodules) who underwent surgery or biopsy after ultrasonography at four hospitals from January 2019 to September 2019. The diagnostic performance metrics of different readers were calculated and compared with the pathologic results. The sensitivity of CAD was outstanding and was equivalent to that of a senior radiologist (90.51% vs. 88.47%, p > 0.05). The area under the curve of CAD was equivalent to that of a junior radiologist (0.748 vs. 0.739, p > 0.05). However, the specificity was only 49.63%, which was lower than those of the three radiologists (75.56%, 85.93% and 90.37% for the junior, intermediate and senior radiologists, respectively). The diagnostic performance of the junior radiologist was significantly improved with the aid of CAD (junior + CAD). The sensitivity and area under the curve of junior + CAD were improved from 72.20% to 89.93% and from 0.739 to 0.816, respectively (both p values <0.05), and the positive predictive value, negative predictive value and κ coefficient improved from 76.3% to 78.6%, 82.0% to 86.8% and 0.394 to 0.511, respectively. Though specificity slightly decreased from 75.56% to 73.33%, the difference was not statistically significant (p > 0.05). In general, the clinical application value of CAD is promising, and its instrumental value for junior radiologists is significant. [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of Ultrasound in Medicine & Biology is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=147116632 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1016/j.ultrasmedbio.2020.09.019 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 11 StartPage: 114 Subjects: – SubjectFull: Diagnostic ultrasonic imaging Type: general – SubjectFull: Thyroid gland Type: general – SubjectFull: Nodular disease Type: general – SubjectFull: Radiologists Type: general – SubjectFull: Thyroid nodules Type: general – SubjectFull: Longitudinal method Type: general – SubjectFull: Computer software Type: general – SubjectFull: Research Type: general – SubjectFull: Ultrasonic imaging Type: general – SubjectFull: Thyroid gland tumors Type: general – SubjectFull: Research methodology Type: general – SubjectFull: Medical cooperation Type: general – SubjectFull: Evaluation research Type: general – SubjectFull: Comparative studies Type: general – SubjectFull: Clinical competence Type: general – SubjectFull: Computer-aided diagnosis Type: general – SubjectFull: Medical specialties & specialists Type: general Titles: – TitleFull: Diagnostic Performance of Ultrasound Computer-Aided Diagnosis Software Compared with That of Radiologists with Different Levels of Expertise for Thyroid Malignancy: A Multicenter Prospective Study. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Ye, Feng-Ying – PersonEntity: Name: NameFull: Lyu, Guo-Rong – PersonEntity: Name: NameFull: Li, Shang-Qing – PersonEntity: Name: NameFull: You, Jian-Hong – PersonEntity: Name: NameFull: Wang, Kang-Jian – PersonEntity: Name: NameFull: Cai, Ming-Li – PersonEntity: Name: NameFull: Su, Qi-Chen IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 01 Text: Jan2021 Type: published Y: 2021 Identifiers: – Type: issn-print Value: 03015629 Numbering: – Type: volume Value: 47 – Type: issue Value: 1 Titles: – TitleFull: Ultrasound in Medicine & Biology Type: main |
| ResultId | 1 |