Aging tests and chemical analysis of Resistive Plate Chambers for the trigger of the ALICE dimuon arm

Saved in:
Bibliographic Details
Title: Aging tests and chemical analysis of Resistive Plate Chambers for the trigger of the ALICE dimuon arm
Authors: Arnaldi, R.1, Chiavassa, E.1, Colla, A.1, Cortese, P.2, Dellacasa, G.2, De Marco, N.1, Ferretti, A.1, Gallio, M.1, Guernane, R.1, Mereu, P.1, Musso, A.1, Oppedisano, C.1, Piccotti, A.1, Poggio, F.1, Scomparin, E.1, Sigaudo, F.1, Travaglia, G. travagli@to.infn.it, Vercellin, E.1, Yermia, F.1
Source: Nuclear Instruments & Methods in Physics Research Section A. Nov2004, Vol. 533 Issue 1/2, p112-115. 4p.
Subjects: Irradiation, Analytical chemistry, Physics instruments, Electric resistors
Abstract: Resistive Plate Chambers operated in streamer mode have been chosen as trigger detectors for the forward dimuon spectrometer of the ALICE experiment. During tests performed at CERN PS, small size prototypes with low-resistivity bakelite electrodes and with a strongly quenched gas mixture have shown the required rate capability, tracking and timing properties. Present efforts are devoted to the study of the detector performance after long irradiation periods. In this paper, a summary of the results of aging tests performed at the Gamma Irradiation Facility at CERN will be presented. Detectors show quite stable performance up to about , as the requirements for 10years operation program at LHC including a safety factor of 2. Afterwards, we observed an increase of the dark current not associated with an increase of the counting rate. We also report results of chemical analysis carried out by different CERN teams on exhaust gases and electrode surfaces of the detectors after aging. [Copyright &y& Elsevier]
Copyright of Nuclear Instruments & Methods in Physics Research Section A is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 14785819
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Aging tests and chemical analysis of Resistive Plate Chambers for the trigger of the ALICE dimuon arm
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Arnaldi%2C+R%2E%22">Arnaldi, R.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Chiavassa%2C+E%2E%22">Chiavassa, E.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Colla%2C+A%2E%22">Colla, A.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Cortese%2C+P%2E%22">Cortese, P.</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Dellacasa%2C+G%2E%22">Dellacasa, G.</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22De+Marco%2C+N%2E%22">De Marco, N.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Ferretti%2C+A%2E%22">Ferretti, A.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Gallio%2C+M%2E%22">Gallio, M.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Guernane%2C+R%2E%22">Guernane, R.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Mereu%2C+P%2E%22">Mereu, P.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Musso%2C+A%2E%22">Musso, A.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Oppedisano%2C+C%2E%22">Oppedisano, C.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Piccotti%2C+A%2E%22">Piccotti, A.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Poggio%2C+F%2E%22">Poggio, F.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Scomparin%2C+E%2E%22">Scomparin, E.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Sigaudo%2C+F%2E%22">Sigaudo, F.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Travaglia%2C+G%2E%22">Travaglia, G.</searchLink><i> travagli@to.infn.it</i><br /><searchLink fieldCode="AR" term="%22Vercellin%2C+E%2E%22">Vercellin, E.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Yermia%2C+F%2E%22">Yermia, F.</searchLink><relatesTo>1</relatesTo>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Nuclear+Instruments+%26+Methods+in+Physics+Research+Section+A%22">Nuclear Instruments & Methods in Physics Research Section A</searchLink>. Nov2004, Vol. 533 Issue 1/2, p112-115. 4p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Irradiation%22">Irradiation</searchLink><br /><searchLink fieldCode="DE" term="%22Analytical+chemistry%22">Analytical chemistry</searchLink><br /><searchLink fieldCode="DE" term="%22Physics+instruments%22">Physics instruments</searchLink><br /><searchLink fieldCode="DE" term="%22Electric+resistors%22">Electric resistors</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Resistive Plate Chambers operated in streamer mode have been chosen as trigger detectors for the forward dimuon spectrometer of the ALICE experiment. During tests performed at CERN PS, small size prototypes with low-resistivity bakelite electrodes and with a strongly quenched gas mixture have shown the required rate capability, tracking and timing properties. Present efforts are devoted to the study of the detector performance after long irradiation periods. In this paper, a summary of the results of aging tests performed at the Gamma Irradiation Facility at CERN will be presented. Detectors show quite stable performance up to about , as the requirements for 10years operation program at LHC including a safety factor of 2. Afterwards, we observed an increase of the dark current not associated with an increase of the counting rate. We also report results of chemical analysis carried out by different CERN teams on exhaust gases and electrode surfaces of the detectors after aging. [Copyright &y& Elsevier]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Nuclear Instruments & Methods in Physics Research Section A is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=14785819
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1016/j.nima.2004.07.011
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 4
        StartPage: 112
    Subjects:
      – SubjectFull: Irradiation
        Type: general
      – SubjectFull: Analytical chemistry
        Type: general
      – SubjectFull: Physics instruments
        Type: general
      – SubjectFull: Electric resistors
        Type: general
    Titles:
      – TitleFull: Aging tests and chemical analysis of Resistive Plate Chambers for the trigger of the ALICE dimuon arm
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Arnaldi, R.
      – PersonEntity:
          Name:
            NameFull: Chiavassa, E.
      – PersonEntity:
          Name:
            NameFull: Colla, A.
      – PersonEntity:
          Name:
            NameFull: Cortese, P.
      – PersonEntity:
          Name:
            NameFull: Dellacasa, G.
      – PersonEntity:
          Name:
            NameFull: De Marco, N.
      – PersonEntity:
          Name:
            NameFull: Ferretti, A.
      – PersonEntity:
          Name:
            NameFull: Gallio, M.
      – PersonEntity:
          Name:
            NameFull: Guernane, R.
      – PersonEntity:
          Name:
            NameFull: Mereu, P.
      – PersonEntity:
          Name:
            NameFull: Musso, A.
      – PersonEntity:
          Name:
            NameFull: Oppedisano, C.
      – PersonEntity:
          Name:
            NameFull: Piccotti, A.
      – PersonEntity:
          Name:
            NameFull: Poggio, F.
      – PersonEntity:
          Name:
            NameFull: Scomparin, E.
      – PersonEntity:
          Name:
            NameFull: Sigaudo, F.
      – PersonEntity:
          Name:
            NameFull: Travaglia, G.
      – PersonEntity:
          Name:
            NameFull: Vercellin, E.
      – PersonEntity:
          Name:
            NameFull: Yermia, F.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 11
              Text: Nov2004
              Type: published
              Y: 2004
          Identifiers:
            – Type: issn-print
              Value: 01689002
          Numbering:
            – Type: volume
              Value: 533
            – Type: issue
              Value: 1/2
          Titles:
            – TitleFull: Nuclear Instruments & Methods in Physics Research Section A
              Type: main
ResultId 1