Deterministic linear Boltzmann transport equation solver for patient‐specific CT dose estimation: Comparison against a Monte Carlo benchmark for realistic scanner configurations and patient models.

Saved in:
Bibliographic Details
Title: Deterministic linear Boltzmann transport equation solver for patient‐specific CT dose estimation: Comparison against a Monte Carlo benchmark for realistic scanner configurations and patient models.
Authors: Principi, Sara1 (AUTHOR) sprincipi@mcw.edu, Wang, Adam2 (AUTHOR), Maslowski, Alexander3 (AUTHOR), Wareing, Todd3 (AUTHOR), Jordan, Petr3 (AUTHOR), Schmidt, Taly Gilat1 (AUTHOR)
Source: Medical Physics. Dec2020, Vol. 47 Issue 12, p6470-6483. 14p.
Subjects: Monte Carlo method, Boltzmann's equation, Computed tomography, Scanning systems, Standard deviations
Abstract: Purpose: Epidemiological evidence suggests an increased risk of cancer related to computed tomography (CT) scans, with children exposed to greater risk. The purpose of this work is to test the reliability of a linear Boltzmann transport equation (LBTE) solver for rapid and patient‐specific CT dose estimation. This includes building a flexible LBTE framework for modeling modern clinical CT scanners and to validate the resulting dose maps across a range of realistic scanner configurations and patient models. Methods: In this study, computational tools were developed for modeling CT scanners, including a bowtie filter, overrange collimation, and tube current modulation. The LBTE solver requires discretization in the spatial, angular, and spectral dimensions, which may affect the accuracy of scanner modeling. To investigate these effects, this study evaluated the LBTE dose accuracy for different discretization parameters, scanner configurations, and patient models (male, female, adults, pediatric). The method used to validate the LBTE dose maps was the Monte Carlo code Geant4, which provided ground truth dose maps. LBTE simulations were implemented on a GeForce GTX 1080 graphic unit, while Geant4 was implemented on a distributed cluster of CPUs. Results: The agreement between Geant4 and the LBTE solver quantifies the accuracy of the LBTE, which was similar across the different protocols and phantoms. The results suggest that 18 views per rotation provides sufficient accuracy, as no significant improvement in the accuracy was observed by increasing the number of projection views. Considering this discretization, the LBTE solver average simulation time was approximately 30 s. However, in the LBTE solver the phantom model was implemented with a lower voxel resolution with respect to Geant4, as it is limited by the memory of the GPU. Despite this discretization, the results showed a good agreement between the LBTE and Geant4, with root mean square error of the dose in organs of approximately 3.5% for most of the studied configurations. Conclusions: The LBTE solver is proposed as an alternative to Monte Carlo for patient‐specific organ dose estimation. This study demonstrated accurate organ dose estimates for the rapid LBTE solver when considering realistic aspects of CT scanners and a range of phantom models. Future plans will combine the LBTE framework with deep learning autosegmentation algorithms to provide near real‐time patient‐specific organ dose estimation. [ABSTRACT FROM AUTHOR]
Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Full text is not displayed to guests.
FullText Links:
  – Type: pdflink
Text:
  Availability: 1
Header DbId: egs
DbLabel: Engineering Source
An: 148021680
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Deterministic linear Boltzmann transport equation solver for patient‐specific CT dose estimation: Comparison against a Monte Carlo benchmark for realistic scanner configurations and patient models.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Principi%2C+Sara%22">Principi, Sara</searchLink><relatesTo>1</relatesTo> (AUTHOR)<i> sprincipi@mcw.edu</i><br /><searchLink fieldCode="AR" term="%22Wang%2C+Adam%22">Wang, Adam</searchLink><relatesTo>2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Maslowski%2C+Alexander%22">Maslowski, Alexander</searchLink><relatesTo>3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Wareing%2C+Todd%22">Wareing, Todd</searchLink><relatesTo>3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Jordan%2C+Petr%22">Jordan, Petr</searchLink><relatesTo>3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Schmidt%2C+Taly+Gilat%22">Schmidt, Taly Gilat</searchLink><relatesTo>1</relatesTo> (AUTHOR)
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Medical+Physics%22">Medical Physics</searchLink>. Dec2020, Vol. 47 Issue 12, p6470-6483. 14p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Monte+Carlo+method%22">Monte Carlo method</searchLink><br /><searchLink fieldCode="DE" term="%22Boltzmann's+equation%22">Boltzmann's equation</searchLink><br /><searchLink fieldCode="DE" term="%22Computed+tomography%22">Computed tomography</searchLink><br /><searchLink fieldCode="DE" term="%22Scanning+systems%22">Scanning systems</searchLink><br /><searchLink fieldCode="DE" term="%22Standard+deviations%22">Standard deviations</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Purpose: Epidemiological evidence suggests an increased risk of cancer related to computed tomography (CT) scans, with children exposed to greater risk. The purpose of this work is to test the reliability of a linear Boltzmann transport equation (LBTE) solver for rapid and patient‐specific CT dose estimation. This includes building a flexible LBTE framework for modeling modern clinical CT scanners and to validate the resulting dose maps across a range of realistic scanner configurations and patient models. Methods: In this study, computational tools were developed for modeling CT scanners, including a bowtie filter, overrange collimation, and tube current modulation. The LBTE solver requires discretization in the spatial, angular, and spectral dimensions, which may affect the accuracy of scanner modeling. To investigate these effects, this study evaluated the LBTE dose accuracy for different discretization parameters, scanner configurations, and patient models (male, female, adults, pediatric). The method used to validate the LBTE dose maps was the Monte Carlo code Geant4, which provided ground truth dose maps. LBTE simulations were implemented on a GeForce GTX 1080 graphic unit, while Geant4 was implemented on a distributed cluster of CPUs. Results: The agreement between Geant4 and the LBTE solver quantifies the accuracy of the LBTE, which was similar across the different protocols and phantoms. The results suggest that 18 views per rotation provides sufficient accuracy, as no significant improvement in the accuracy was observed by increasing the number of projection views. Considering this discretization, the LBTE solver average simulation time was approximately 30 s. However, in the LBTE solver the phantom model was implemented with a lower voxel resolution with respect to Geant4, as it is limited by the memory of the GPU. Despite this discretization, the results showed a good agreement between the LBTE and Geant4, with root mean square error of the dose in organs of approximately 3.5% for most of the studied configurations. Conclusions: The LBTE solver is proposed as an alternative to Monte Carlo for patient‐specific organ dose estimation. This study demonstrated accurate organ dose estimates for the rapid LBTE solver when considering realistic aspects of CT scanners and a range of phantom models. Future plans will combine the LBTE framework with deep learning autosegmentation algorithms to provide near real‐time patient‐specific organ dose estimation. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=148021680
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1002/mp.14494
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 14
        StartPage: 6470
    Subjects:
      – SubjectFull: Monte Carlo method
        Type: general
      – SubjectFull: Boltzmann's equation
        Type: general
      – SubjectFull: Computed tomography
        Type: general
      – SubjectFull: Scanning systems
        Type: general
      – SubjectFull: Standard deviations
        Type: general
    Titles:
      – TitleFull: Deterministic linear Boltzmann transport equation solver for patient‐specific CT dose estimation: Comparison against a Monte Carlo benchmark for realistic scanner configurations and patient models.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Principi, Sara
      – PersonEntity:
          Name:
            NameFull: Wang, Adam
      – PersonEntity:
          Name:
            NameFull: Maslowski, Alexander
      – PersonEntity:
          Name:
            NameFull: Wareing, Todd
      – PersonEntity:
          Name:
            NameFull: Jordan, Petr
      – PersonEntity:
          Name:
            NameFull: Schmidt, Taly Gilat
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 12
              Text: Dec2020
              Type: published
              Y: 2020
          Identifiers:
            – Type: issn-print
              Value: 00942405
          Numbering:
            – Type: volume
              Value: 47
            – Type: issue
              Value: 12
          Titles:
            – TitleFull: Medical Physics
              Type: main
ResultId 1