Modular input‐parallel output‐series DC/DC converter control with fault detection and redundancy.

Saved in:
Bibliographic Details
Title: Modular input‐parallel output‐series DC/DC converter control with fault detection and redundancy.
Authors: Lian, Yiqing1 (AUTHOR) yiqing.lian@strath.ac.uk, Adam, Grain1 (AUTHOR), Holliday, Derrick1 (AUTHOR), Finney, Stephen1 (AUTHOR)
Source: IET Generation, Transmission & Distribution (Wiley-Blackwell). Apr2016, Vol. 10 Issue 6, p1361-1369. 9p.
Abstract: Large offshore wind farms require extensive sub‐sea cables within the collection network. Present solutions are based around medium‐voltage AC collection networks. Recent studies have highlighted the potential benefits of DC collection networks. However, achieving DC/DC conversion at the required voltage and power levels presents a significant challenge for wind‐turbine power electronics. This study proposes an alternative DC collection network based around a modular DC/DC converter with input‐parallel output‐series connection. This modular topology can overcome the limitations imposed by semiconductor voltage ratings and provides fault‐tolerant operation. Small‐signal analysis of the converter is presented to be used to facilitate controller design for the converter input and output stages. A new master–slave control scheme and distributed voltage sharing controllers are proposed that ensure power sharing under all operating conditions, including during failure of a master module. This control scheme achieves fault‐tolerant operation by allowing the status of master module to be reallocated to any healthy module. The proposed control scheme is validated using simulation and experimentation, considering active power sharing between modules with parameter mismatch. [ABSTRACT FROM AUTHOR]
Copyright of IET Generation, Transmission & Distribution (Wiley-Blackwell) is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 148082548
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Modular input‐parallel output‐series DC/DC converter control with fault detection and redundancy.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Lian%2C+Yiqing%22">Lian, Yiqing</searchLink><relatesTo>1</relatesTo> (AUTHOR)<i> yiqing.lian@strath.ac.uk</i><br /><searchLink fieldCode="AR" term="%22Adam%2C+Grain%22">Adam, Grain</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Holliday%2C+Derrick%22">Holliday, Derrick</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Finney%2C+Stephen%22">Finney, Stephen</searchLink><relatesTo>1</relatesTo> (AUTHOR)
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22IET+Generation%2C+Transmission+%26+Distribution+%28Wiley-Blackwell%29%22">IET Generation, Transmission & Distribution (Wiley-Blackwell)</searchLink>. Apr2016, Vol. 10 Issue 6, p1361-1369. 9p.
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Large offshore wind farms require extensive sub‐sea cables within the collection network. Present solutions are based around medium‐voltage AC collection networks. Recent studies have highlighted the potential benefits of DC collection networks. However, achieving DC/DC conversion at the required voltage and power levels presents a significant challenge for wind‐turbine power electronics. This study proposes an alternative DC collection network based around a modular DC/DC converter with input‐parallel output‐series connection. This modular topology can overcome the limitations imposed by semiconductor voltage ratings and provides fault‐tolerant operation. Small‐signal analysis of the converter is presented to be used to facilitate controller design for the converter input and output stages. A new master–slave control scheme and distributed voltage sharing controllers are proposed that ensure power sharing under all operating conditions, including during failure of a master module. This control scheme achieves fault‐tolerant operation by allowing the status of master module to be reallocated to any healthy module. The proposed control scheme is validated using simulation and experimentation, considering active power sharing between modules with parameter mismatch. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of IET Generation, Transmission & Distribution (Wiley-Blackwell) is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=148082548
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1049/iet-gtd.2015.0789
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 9
        StartPage: 1361
    Titles:
      – TitleFull: Modular input‐parallel output‐series DC/DC converter control with fault detection and redundancy.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Lian, Yiqing
      – PersonEntity:
          Name:
            NameFull: Adam, Grain
      – PersonEntity:
          Name:
            NameFull: Holliday, Derrick
      – PersonEntity:
          Name:
            NameFull: Finney, Stephen
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 04
              Text: Apr2016
              Type: published
              Y: 2016
          Identifiers:
            – Type: issn-print
              Value: 17518687
          Numbering:
            – Type: volume
              Value: 10
            – Type: issue
              Value: 6
          Titles:
            – TitleFull: IET Generation, Transmission & Distribution (Wiley-Blackwell)
              Type: main
ResultId 1