I‐Q imbalance correction of microwave displacement sensors.

Saved in:
Bibliographic Details
Title: I‐Q imbalance correction of microwave displacement sensors.
Authors: Pieraccini, M.1 (AUTHOR) massimiliano.pieraccini@unifi.it, Papi, F.1 (AUTHOR), Donati, N.1 (AUTHOR)
Source: Electronics Letters (Wiley-Blackwell). Jun2015, Vol. 51 Issue 12, p1021-1023. 3p.
Abstract: Microwave displacement sensors are becoming increasingly popular as vital sign detectors and structural vibration detectors. Until now there is not any method known for calibrating them that does not require accessing the electronic board by inserting and probing test signals or does not require cumbersome equipment that is able to provide large linear displacements. Hence, proposed is a calibration method for I‐Q correction that makes use only of an external mechanical oscillator (a metallic bar fixed at an edge). As a test device, a low‐quality X‐band transceiver with a strong imbalance has been used. The calibrated sensor is compared successfully with a high‐performance seismic accelerometer. [ABSTRACT FROM AUTHOR]
Copyright of Electronics Letters (Wiley-Blackwell) is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 148783070
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: I‐Q imbalance correction of microwave displacement sensors.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Pieraccini%2C+M%2E%22">Pieraccini, M.</searchLink><relatesTo>1</relatesTo> (AUTHOR)<i> massimiliano.pieraccini@unifi.it</i><br /><searchLink fieldCode="AR" term="%22Papi%2C+F%2E%22">Papi, F.</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Donati%2C+N%2E%22">Donati, N.</searchLink><relatesTo>1</relatesTo> (AUTHOR)
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Electronics+Letters+%28Wiley-Blackwell%29%22">Electronics Letters (Wiley-Blackwell)</searchLink>. Jun2015, Vol. 51 Issue 12, p1021-1023. 3p.
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Microwave displacement sensors are becoming increasingly popular as vital sign detectors and structural vibration detectors. Until now there is not any method known for calibrating them that does not require accessing the electronic board by inserting and probing test signals or does not require cumbersome equipment that is able to provide large linear displacements. Hence, proposed is a calibration method for I‐Q correction that makes use only of an external mechanical oscillator (a metallic bar fixed at an edge). As a test device, a low‐quality X‐band transceiver with a strong imbalance has been used. The calibrated sensor is compared successfully with a high‐performance seismic accelerometer. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Electronics Letters (Wiley-Blackwell) is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=148783070
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1049/el.2015.0982
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 3
        StartPage: 1021
    Titles:
      – TitleFull: I‐Q imbalance correction of microwave displacement sensors.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Pieraccini, M.
      – PersonEntity:
          Name:
            NameFull: Papi, F.
      – PersonEntity:
          Name:
            NameFull: Donati, N.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 06
              Text: Jun2015
              Type: published
              Y: 2015
          Identifiers:
            – Type: issn-print
              Value: 00135194
          Numbering:
            – Type: volume
              Value: 51
            – Type: issue
              Value: 12
          Titles:
            – TitleFull: Electronics Letters (Wiley-Blackwell)
              Type: main
ResultId 1