Ultra-low-dose CT versus radiographs for minor spine and pelvis trauma: a Bayesian analysis of accuracy.

Saved in:
Bibliographic Details
Title: Ultra-low-dose CT versus radiographs for minor spine and pelvis trauma: a Bayesian analysis of accuracy.
Authors: Hamard, Aymeric1 (AUTHOR) aymeric.hamard@chu-nimes.fr, Greffier, Joel1 (AUTHOR), Bastide, Sophie2 (AUTHOR), Larbi, Ahmed1 (AUTHOR), Addala, Takieddine1 (AUTHOR), Sadate, Alexandre1 (AUTHOR), Beregi, Jean-Paul1 (AUTHOR), Frandon, Julien1 (AUTHOR)
Source: European Radiology. Apr2021, Vol. 31 Issue 4, p2621-2633. 13p. 3 Black and White Photographs, 1 Diagram, 4 Charts, 1 Graph.
Subjects: Radiographs, Bayesian analysis, Computed tomography, Pelvis, Spine
Abstract: Objectives: To compare diagnosis performance and effective dose of ultra-low-dose CT (ULD CT) versus radiographs in suspected spinal or pelvic ring or hip fracture for minor trauma. Methods: ULD CT, in addition to radiography, was prospectively performed in consecutive patients admitted to the emergency department for minor traumas, during working hours over 2 months. Presence of a recent fracture was assessed by two blind radiologists independently. Sensitivities and specificities were estimated using the best valuable comparator (BVC) as a reference and using a latent class model in Bayesian inference (BLCM). Dosimetric indicators were recorded and effective doses (E) were calculated using conversion coefficient. Results: Eighty areas were analyzed in 69 patients, including 22 dorsal spine, 28 lumbar spine, and 30 pelvic ring/hip. Thirty-six fractures (45%) were observed. Applying the BVC method, depending on location, ULD CT sensitivity was 80 to 100% for reader 1 and 85 to 100% for reader 2, whereas radiographic sensitivity was 60 to 85% for reader 1 and 50 to 92% for reader 2. With BLCM approach for reader 2, ULD CT sensitivity for all locations/dorsal spine/lumbar spine and pelvic ring-hip was 87.1/75.9/84.2/76.9% respectively. Corresponding radiograph sensitivity was 73.8, 54.8, 80.4, and 68.7%. Effective doses of ULD CT were similar to radiographs for dorsal and hip locations whereas for lumbar spine, ULD CT effective dose was 1.83 ± 0.59 mSv compared with 0.96 ± 0.59 mSv (p < 0.001). Conclusion: Sensitivity for fracture detection was higher for ULD CT compared with radiographs with an effective dose comparable to radiographs. Key Points: • Ultra-low-dose spine and pelvis CT demonstrates better fracture detection when compared with radiographs. • The effective dose of ultra-low-dose spine and pelvis CT scan and radiographs is comparable. • Replacement of radiographs by ULD CT in daily practice for trauma patients is an option to consider and should be evaluated by a randomized trial. [ABSTRACT FROM AUTHOR]
Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Links:
  – Type: pdflink
Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 149373447
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Ultra-low-dose CT versus radiographs for minor spine and pelvis trauma: a Bayesian analysis of accuracy.
– Name: Author
  Label: Authors
  Group: Au
  Data: &lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Hamard%2C+Aymeric%22&quot;&gt;Hamard, Aymeric&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt; (AUTHOR)&lt;i&gt; aymeric.hamard@chu-nimes.fr&lt;/i&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Greffier%2C+Joel%22&quot;&gt;Greffier, Joel&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Bastide%2C+Sophie%22&quot;&gt;Bastide, Sophie&lt;/searchLink&gt;&lt;relatesTo&gt;2&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Larbi%2C+Ahmed%22&quot;&gt;Larbi, Ahmed&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Addala%2C+Takieddine%22&quot;&gt;Addala, Takieddine&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Sadate%2C+Alexandre%22&quot;&gt;Sadate, Alexandre&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Beregi%2C+Jean-Paul%22&quot;&gt;Beregi, Jean-Paul&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Frandon%2C+Julien%22&quot;&gt;Frandon, Julien&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt; (AUTHOR)
– Name: TitleSource
  Label: Source
  Group: Src
  Data: &lt;searchLink fieldCode=&quot;JN&quot; term=&quot;%22European+Radiology%22&quot;&gt;European Radiology&lt;/searchLink&gt;. Apr2021, Vol. 31 Issue 4, p2621-2633. 13p. 3 Black and White Photographs, 1 Diagram, 4 Charts, 1 Graph.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: &lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Radiographs%22&quot;&gt;Radiographs&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Bayesian+analysis%22&quot;&gt;Bayesian analysis&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Computed+tomography%22&quot;&gt;Computed tomography&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Pelvis%22&quot;&gt;Pelvis&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Spine%22&quot;&gt;Spine&lt;/searchLink&gt;
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Objectives: To compare diagnosis performance and effective dose of ultra-low-dose CT (ULD CT) versus radiographs in suspected spinal or pelvic ring or hip fracture for minor trauma. Methods: ULD CT, in addition to radiography, was prospectively performed in consecutive patients admitted to the emergency department for minor traumas, during working hours over 2 months. Presence of a recent fracture was assessed by two blind radiologists independently. Sensitivities and specificities were estimated using the best valuable comparator (BVC) as a reference and using a latent class model in Bayesian inference (BLCM). Dosimetric indicators were recorded and effective doses (E) were calculated using conversion coefficient. Results: Eighty areas were analyzed in 69 patients, including 22 dorsal spine, 28 lumbar spine, and 30 pelvic ring/hip. Thirty-six fractures (45%) were observed. Applying the BVC method, depending on location, ULD CT sensitivity was 80 to 100% for reader 1 and 85 to 100% for reader 2, whereas radiographic sensitivity was 60 to 85% for reader 1 and 50 to 92% for reader 2. With BLCM approach for reader 2, ULD CT sensitivity for all locations/dorsal spine/lumbar spine and pelvic ring-hip was 87.1/75.9/84.2/76.9% respectively. Corresponding radiograph sensitivity was 73.8, 54.8, 80.4, and 68.7%. Effective doses of ULD CT were similar to radiographs for dorsal and hip locations whereas for lumbar spine, ULD CT effective dose was 1.83 &#177; 0.59 mSv compared with 0.96 &#177; 0.59 mSv (p &lt; 0.001). Conclusion: Sensitivity for fracture detection was higher for ULD CT compared with radiographs with an effective dose comparable to radiographs. Key Points: • Ultra-low-dose spine and pelvis CT demonstrates better fracture detection when compared with radiographs. • The effective dose of ultra-low-dose spine and pelvis CT scan and radiographs is comparable. • Replacement of radiographs by ULD CT in daily practice for trauma patients is an option to consider and should be evaluated by a randomized trial. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: &lt;i&gt;Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder&#39;s express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.&lt;/i&gt; (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=149373447
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1007/s00330-020-07304-8
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 13
        StartPage: 2621
    Subjects:
      – SubjectFull: Radiographs
        Type: general
      – SubjectFull: Bayesian analysis
        Type: general
      – SubjectFull: Computed tomography
        Type: general
      – SubjectFull: Pelvis
        Type: general
      – SubjectFull: Spine
        Type: general
    Titles:
      – TitleFull: Ultra-low-dose CT versus radiographs for minor spine and pelvis trauma: a Bayesian analysis of accuracy.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Hamard, Aymeric
      – PersonEntity:
          Name:
            NameFull: Greffier, Joel
      – PersonEntity:
          Name:
            NameFull: Bastide, Sophie
      – PersonEntity:
          Name:
            NameFull: Larbi, Ahmed
      – PersonEntity:
          Name:
            NameFull: Addala, Takieddine
      – PersonEntity:
          Name:
            NameFull: Sadate, Alexandre
      – PersonEntity:
          Name:
            NameFull: Beregi, Jean-Paul
      – PersonEntity:
          Name:
            NameFull: Frandon, Julien
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 04
              Text: Apr2021
              Type: published
              Y: 2021
          Identifiers:
            – Type: issn-print
              Value: 09387994
          Numbering:
            – Type: volume
              Value: 31
            – Type: issue
              Value: 4
          Titles:
            – TitleFull: European Radiology
              Type: main
ResultId 1