Quantifying pulmonary perfusion from noncontrast computed tomography.

Saved in:
Bibliographic Details
Title: Quantifying pulmonary perfusion from noncontrast computed tomography.
Authors: Castillo, Edward1,2 (AUTHOR) Edward.Castillo@beaumont.edu, Nair, Girish3 (AUTHOR), Turner‐Lawrence, Danielle4 (AUTHOR), Myziuk, Nicholas1 (AUTHOR), Emerson, Scott5 (AUTHOR), Al‐Katib, Sayf5 (AUTHOR), Westergaard, Sarah6 (AUTHOR), Castillo, Richard6 (AUTHOR), Vinogradskiy, Yevgeniy7 (AUTHOR), Quinn, Thomas1 (AUTHOR), Guerrero, Thomas1 (AUTHOR), Stevens, Craig1 (AUTHOR)
Source: Medical Physics. Apr2021, Vol. 48 Issue 4, p1804-1814. 11p.
Subjects: Computed tomography, Non-small-cell lung carcinoma, Lung volume, Perfusion, Photon emission, Image registration, Conservation of mass
Abstract: Purpose: Computed tomography (CT)‐derived ventilation methods compute respiratory induced volume changes as a surrogate for pulmonary ventilation. Currently, there are no known methods to derive perfusion information from noncontrast CT. We introduce a novel CT‐Perfusion (CT‐P) method for computing the magnitude mass changes apparent on dynamic noncontrast CT as a surrogate for pulmonary perfusion. Methods: CT‐Perfusion is based on a mass conservation model which describes the unknown mass change as a linear combination of spatially corresponding inhale and exhale HU estimated voxel densities. CT‐P requires a deformable image registration (DIR) between the inhale/exhale lung CT pair, a preprocessing lung volume segmentation, and an estimate for the Jacobian of the DIR transformation. Given this information, the CT‐P image, which provides the magnitude mass change for each voxel within the lung volume, is formulated as the solution to a constrained linear least squares problem defined by a series of subregional mean magnitude mass change measurements. Similar to previous robust CT‐ventilation methods, the amount of uncertainty in a subregional sample mean measurement is related to measurement resolution and can be characterized with respect to a tolerance parameter τ. Spatial Spearman correlation between single photon emission CT perfusion (SPECT‐P) and the proposed CT‐P method was assessed in two patient cohorts via a parameter sweep of τ. The first cohort was comprised of 15 patients diagnosed with pulmonary embolism (PE) who had SPECT‐P and 4DCT imaging acquired within 24 h of PE diagnosis. The second cohort was comprised of 15 nonsmall cell lung cancer patients who had SPECT‐P and 4DCT images acquired prior to radiotherapy. For each test case, CT‐P images were computed for 30 different uncertainty parameter values, uniformly sampled from the range [0.01, 0.125], and the Spearman correlation between the SPECT‐P and the resulting CT‐P images were computed. Results: The median correlations between CT‐P and SPECT‐P taken over all 30 test cases ranged between 0.49 and 0.57 across the parameter sweep. For the optimal tolerance τ = 0.0385, the CT‐P and SPECT‐P correlations across all 30 test cases ranged between 0.02 and 0.82. A one‐sample sign test was applied separately to the PE and lung cancer cohorts. A low Spearmen correlation of 15% was set as the null median value and two‐sided alternative was tested. The PE patients showed a median correlation of 0.57 (IQR = 0.305). One‐sample sign test was statistically significant with 96.5 % confidence interval: 0.20–0.63, P < 0.00001. Lung cancer patients had a median correlation of 0.57(IQR = 0.230). Again, a one‐sample sign test for median was statistically significant with 96.5 percent confidence interval: 0.45–0.71, P < 0.00001. Conclusion: CT‐Perfusion is the first mechanistic model designed to quantify magnitude blood mass changes on noncontrast dynamic CT as a surrogate for pulmonary perfusion. While the reported correlations with SPECT‐P are promising, further investigation is required to determine the optimal CT acquisition protocol and numerical method implementation for CT‐P imaging. [ABSTRACT FROM AUTHOR]
Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Links:
  – Type: pdflink
Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 149900994
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Quantifying pulmonary perfusion from noncontrast computed tomography.
– Name: Author
  Label: Authors
  Group: Au
  Data: &lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Castillo%2C+Edward%22&quot;&gt;Castillo, Edward&lt;/searchLink&gt;&lt;relatesTo&gt;1,2&lt;/relatesTo&gt; (AUTHOR)&lt;i&gt; Edward.Castillo@beaumont.edu&lt;/i&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Nair%2C+Girish%22&quot;&gt;Nair, Girish&lt;/searchLink&gt;&lt;relatesTo&gt;3&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Turner‐Lawrence%2C+Danielle%22&quot;&gt;Turner‐Lawrence, Danielle&lt;/searchLink&gt;&lt;relatesTo&gt;4&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Myziuk%2C+Nicholas%22&quot;&gt;Myziuk, Nicholas&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Emerson%2C+Scott%22&quot;&gt;Emerson, Scott&lt;/searchLink&gt;&lt;relatesTo&gt;5&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Al‐Katib%2C+Sayf%22&quot;&gt;Al‐Katib, Sayf&lt;/searchLink&gt;&lt;relatesTo&gt;5&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Westergaard%2C+Sarah%22&quot;&gt;Westergaard, Sarah&lt;/searchLink&gt;&lt;relatesTo&gt;6&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Castillo%2C+Richard%22&quot;&gt;Castillo, Richard&lt;/searchLink&gt;&lt;relatesTo&gt;6&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Vinogradskiy%2C+Yevgeniy%22&quot;&gt;Vinogradskiy, Yevgeniy&lt;/searchLink&gt;&lt;relatesTo&gt;7&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Quinn%2C+Thomas%22&quot;&gt;Quinn, Thomas&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Guerrero%2C+Thomas%22&quot;&gt;Guerrero, Thomas&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Stevens%2C+Craig%22&quot;&gt;Stevens, Craig&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt; (AUTHOR)
– Name: TitleSource
  Label: Source
  Group: Src
  Data: &lt;searchLink fieldCode=&quot;JN&quot; term=&quot;%22Medical+Physics%22&quot;&gt;Medical Physics&lt;/searchLink&gt;. Apr2021, Vol. 48 Issue 4, p1804-1814. 11p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: &lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Computed+tomography%22&quot;&gt;Computed tomography&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Non-small-cell+lung+carcinoma%22&quot;&gt;Non-small-cell lung carcinoma&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Lung+volume%22&quot;&gt;Lung volume&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Perfusion%22&quot;&gt;Perfusion&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Photon+emission%22&quot;&gt;Photon emission&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Image+registration%22&quot;&gt;Image registration&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Conservation+of+mass%22&quot;&gt;Conservation of mass&lt;/searchLink&gt;
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Purpose: Computed tomography (CT)‐derived ventilation methods compute respiratory induced volume changes as a surrogate for pulmonary ventilation. Currently, there are no known methods to derive perfusion information from noncontrast CT. We introduce a novel CT‐Perfusion (CT‐P) method for computing the magnitude mass changes apparent on dynamic noncontrast CT as a surrogate for pulmonary perfusion. Methods: CT‐Perfusion is based on a mass conservation model which describes the unknown mass change as a linear combination of spatially corresponding inhale and exhale HU estimated voxel densities. CT‐P requires a deformable image registration (DIR) between the inhale/exhale lung CT pair, a preprocessing lung volume segmentation, and an estimate for the Jacobian of the DIR transformation. Given this information, the CT‐P image, which provides the magnitude mass change for each voxel within the lung volume, is formulated as the solution to a constrained linear least squares problem defined by a series of subregional mean magnitude mass change measurements. Similar to previous robust CT‐ventilation methods, the amount of uncertainty in a subregional sample mean measurement is related to measurement resolution and can be characterized with respect to a tolerance parameter τ. Spatial Spearman correlation between single photon emission CT perfusion (SPECT‐P) and the proposed CT‐P method was assessed in two patient cohorts via a parameter sweep of τ. The first cohort was comprised of 15 patients diagnosed with pulmonary embolism (PE) who had SPECT‐P and 4DCT imaging acquired within 24 h of PE diagnosis. The second cohort was comprised of 15 nonsmall cell lung cancer patients who had SPECT‐P and 4DCT images acquired prior to radiotherapy. For each test case, CT‐P images were computed for 30 different uncertainty parameter values, uniformly sampled from the range [0.01, 0.125], and the Spearman correlation between the SPECT‐P and the resulting CT‐P images were computed. Results: The median correlations between CT‐P and SPECT‐P taken over all 30 test cases ranged between 0.49 and 0.57 across the parameter sweep. For the optimal tolerance τ = 0.0385, the CT‐P and SPECT‐P correlations across all 30 test cases ranged between 0.02 and 0.82. A one‐sample sign test was applied separately to the PE and lung cancer cohorts. A low Spearmen correlation of 15% was set as the null median value and two‐sided alternative was tested. The PE patients showed a median correlation of 0.57 (IQR = 0.305). One‐sample sign test was statistically significant with 96.5 % confidence interval: 0.20–0.63, P &lt; 0.00001. Lung cancer patients had a median correlation of 0.57(IQR = 0.230). Again, a one‐sample sign test for median was statistically significant with 96.5 percent confidence interval: 0.45–0.71, P &lt; 0.00001. Conclusion: CT‐Perfusion is the first mechanistic model designed to quantify magnitude blood mass changes on noncontrast dynamic CT as a surrogate for pulmonary perfusion. While the reported correlations with SPECT‐P are promising, further investigation is required to determine the optimal CT acquisition protocol and numerical method implementation for CT‐P imaging. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: &lt;i&gt;Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder&#39;s express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.&lt;/i&gt; (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=149900994
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1002/mp.14792
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 11
        StartPage: 1804
    Subjects:
      – SubjectFull: Computed tomography
        Type: general
      – SubjectFull: Non-small-cell lung carcinoma
        Type: general
      – SubjectFull: Lung volume
        Type: general
      – SubjectFull: Perfusion
        Type: general
      – SubjectFull: Photon emission
        Type: general
      – SubjectFull: Image registration
        Type: general
      – SubjectFull: Conservation of mass
        Type: general
    Titles:
      – TitleFull: Quantifying pulmonary perfusion from noncontrast computed tomography.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Castillo, Edward
      – PersonEntity:
          Name:
            NameFull: Nair, Girish
      – PersonEntity:
          Name:
            NameFull: Turner‐Lawrence, Danielle
      – PersonEntity:
          Name:
            NameFull: Myziuk, Nicholas
      – PersonEntity:
          Name:
            NameFull: Emerson, Scott
      – PersonEntity:
          Name:
            NameFull: Al‐Katib, Sayf
      – PersonEntity:
          Name:
            NameFull: Westergaard, Sarah
      – PersonEntity:
          Name:
            NameFull: Castillo, Richard
      – PersonEntity:
          Name:
            NameFull: Vinogradskiy, Yevgeniy
      – PersonEntity:
          Name:
            NameFull: Quinn, Thomas
      – PersonEntity:
          Name:
            NameFull: Guerrero, Thomas
      – PersonEntity:
          Name:
            NameFull: Stevens, Craig
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 04
              Text: Apr2021
              Type: published
              Y: 2021
          Identifiers:
            – Type: issn-print
              Value: 00942405
          Numbering:
            – Type: volume
              Value: 48
            – Type: issue
              Value: 4
          Titles:
            – TitleFull: Medical Physics
              Type: main
ResultId 1