AAPM Task Group 241: A medical physicist's guide to MRI‐guided focused ultrasound body systems.
Saved in:
| Title: | AAPM Task Group 241: A medical physicist's guide to MRI‐guided focused ultrasound body systems. |
|---|---|
| Authors: | Payne, Allison1 (AUTHOR), Chopra, Rajiv2 (AUTHOR), Ellens, Nicholas3 (AUTHOR), Chen, Lili4 (AUTHOR), Ghanouni, Pejman5 (AUTHOR), Sammet, Steffen6 (AUTHOR), Diederich, Chris7 (AUTHOR), ter Haar, Gail8 (AUTHOR), Parker, Dennis1 (AUTHOR), Moonen, Chrit9 (AUTHOR), Stafford, Jason10 (AUTHOR), Moros, Eduardo11 (AUTHOR), Schlesinger, David12 (AUTHOR), Benedict, Stanley13 (AUTHOR), Wear, Keith14 (AUTHOR), Partanen, Ari15 (AUTHOR), Farahani, Keyvan16 (AUTHOR) |
| Source: | Medical Physics. Sep2021, Vol. 48 Issue 9, pe772-e806. 35p. |
| Subjects: | United States. Food & Drug Administration, Physicists, Magnetic resonance imaging, Medical physics, Workflow, Quality assurance |
| Abstract: | Magnetic resonance‐guided focused ultrasound (MRgFUS) is a completely non‐invasive technology that has been approved by FDA to treat several diseases. This report, prepared by the American Association of Physicist in Medicine (AAPM) Task Group 241, provides background on MRgFUS technology with a focus on clinical body MRgFUS systems. The report addresses the issues of interest to the medical physics community, specific to the body MRgFUS system configuration, and provides recommendations on how to successfully implement and maintain a clinical MRgFUS program. The following sections describe the key features of typical MRgFUS systems and clinical workflow and provide key points and best practices for the medical physicist. Commonly used terms, metrics and physics are defined and sources of uncertainty that affect MRgFUS procedures are described. Finally, safety and quality assurance procedures are explained, the recommended role of the medical physicist in MRgFUS procedures is described, and regulatory requirements for planning clinical trials are detailed. Although this report is limited in scope to clinical body MRgFUS systems that are approved or currently undergoing clinical trials in the United States, much of the material presented is also applicable to systems designed for other applications. [ABSTRACT FROM AUTHOR] |
| Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
| FullText | Links: – Type: pdflink Text: Availability: 0 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 152558777 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: AAPM Task Group 241: A medical physicist's guide to MRI‐guided focused ultrasound body systems. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Payne%2C+Allison%22">Payne, Allison</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Chopra%2C+Rajiv%22">Chopra, Rajiv</searchLink><relatesTo>2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Ellens%2C+Nicholas%22">Ellens, Nicholas</searchLink><relatesTo>3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Chen%2C+Lili%22">Chen, Lili</searchLink><relatesTo>4</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Ghanouni%2C+Pejman%22">Ghanouni, Pejman</searchLink><relatesTo>5</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Sammet%2C+Steffen%22">Sammet, Steffen</searchLink><relatesTo>6</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Diederich%2C+Chris%22">Diederich, Chris</searchLink><relatesTo>7</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22ter+Haar%2C+Gail%22">ter Haar, Gail</searchLink><relatesTo>8</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Parker%2C+Dennis%22">Parker, Dennis</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Moonen%2C+Chrit%22">Moonen, Chrit</searchLink><relatesTo>9</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Stafford%2C+Jason%22">Stafford, Jason</searchLink><relatesTo>10</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Moros%2C+Eduardo%22">Moros, Eduardo</searchLink><relatesTo>11</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Schlesinger%2C+David%22">Schlesinger, David</searchLink><relatesTo>12</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Benedict%2C+Stanley%22">Benedict, Stanley</searchLink><relatesTo>13</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Wear%2C+Keith%22">Wear, Keith</searchLink><relatesTo>14</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Partanen%2C+Ari%22">Partanen, Ari</searchLink><relatesTo>15</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Farahani%2C+Keyvan%22">Farahani, Keyvan</searchLink><relatesTo>16</relatesTo> (AUTHOR) – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Medical+Physics%22">Medical Physics</searchLink>. Sep2021, Vol. 48 Issue 9, pe772-e806. 35p. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22United+States%2E+Food+%26+Drug+Administration%22">United States. Food & Drug Administration</searchLink><br /><searchLink fieldCode="DE" term="%22Physicists%22">Physicists</searchLink><br /><searchLink fieldCode="DE" term="%22Magnetic+resonance+imaging%22">Magnetic resonance imaging</searchLink><br /><searchLink fieldCode="DE" term="%22Medical+physics%22">Medical physics</searchLink><br /><searchLink fieldCode="DE" term="%22Workflow%22">Workflow</searchLink><br /><searchLink fieldCode="DE" term="%22Quality+assurance%22">Quality assurance</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: Magnetic resonance‐guided focused ultrasound (MRgFUS) is a completely non‐invasive technology that has been approved by FDA to treat several diseases. This report, prepared by the American Association of Physicist in Medicine (AAPM) Task Group 241, provides background on MRgFUS technology with a focus on clinical body MRgFUS systems. The report addresses the issues of interest to the medical physics community, specific to the body MRgFUS system configuration, and provides recommendations on how to successfully implement and maintain a clinical MRgFUS program. The following sections describe the key features of typical MRgFUS systems and clinical workflow and provide key points and best practices for the medical physicist. Commonly used terms, metrics and physics are defined and sources of uncertainty that affect MRgFUS procedures are described. Finally, safety and quality assurance procedures are explained, the recommended role of the medical physicist in MRgFUS procedures is described, and regulatory requirements for planning clinical trials are detailed. Although this report is limited in scope to clinical body MRgFUS systems that are approved or currently undergoing clinical trials in the United States, much of the material presented is also applicable to systems designed for other applications. [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=152558777 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1002/mp.15076 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 35 StartPage: e772 Subjects: – SubjectFull: United States. Food & Drug Administration Type: general – SubjectFull: Physicists Type: general – SubjectFull: Magnetic resonance imaging Type: general – SubjectFull: Medical physics Type: general – SubjectFull: Workflow Type: general – SubjectFull: Quality assurance Type: general Titles: – TitleFull: AAPM Task Group 241: A medical physicist's guide to MRI‐guided focused ultrasound body systems. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Payne, Allison – PersonEntity: Name: NameFull: Chopra, Rajiv – PersonEntity: Name: NameFull: Ellens, Nicholas – PersonEntity: Name: NameFull: Chen, Lili – PersonEntity: Name: NameFull: Ghanouni, Pejman – PersonEntity: Name: NameFull: Sammet, Steffen – PersonEntity: Name: NameFull: Diederich, Chris – PersonEntity: Name: NameFull: ter Haar, Gail – PersonEntity: Name: NameFull: Parker, Dennis – PersonEntity: Name: NameFull: Moonen, Chrit – PersonEntity: Name: NameFull: Stafford, Jason – PersonEntity: Name: NameFull: Moros, Eduardo – PersonEntity: Name: NameFull: Schlesinger, David – PersonEntity: Name: NameFull: Benedict, Stanley – PersonEntity: Name: NameFull: Wear, Keith – PersonEntity: Name: NameFull: Partanen, Ari – PersonEntity: Name: NameFull: Farahani, Keyvan IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 09 Text: Sep2021 Type: published Y: 2021 Identifiers: – Type: issn-print Value: 00942405 Numbering: – Type: volume Value: 48 – Type: issue Value: 9 Titles: – TitleFull: Medical Physics Type: main |
| ResultId | 1 |