AAPM Task Group 241: A medical physicist's guide to MRI‐guided focused ultrasound body systems.

Saved in:
Bibliographic Details
Title: AAPM Task Group 241: A medical physicist's guide to MRI‐guided focused ultrasound body systems.
Authors: Payne, Allison1 (AUTHOR), Chopra, Rajiv2 (AUTHOR), Ellens, Nicholas3 (AUTHOR), Chen, Lili4 (AUTHOR), Ghanouni, Pejman5 (AUTHOR), Sammet, Steffen6 (AUTHOR), Diederich, Chris7 (AUTHOR), ter Haar, Gail8 (AUTHOR), Parker, Dennis1 (AUTHOR), Moonen, Chrit9 (AUTHOR), Stafford, Jason10 (AUTHOR), Moros, Eduardo11 (AUTHOR), Schlesinger, David12 (AUTHOR), Benedict, Stanley13 (AUTHOR), Wear, Keith14 (AUTHOR), Partanen, Ari15 (AUTHOR), Farahani, Keyvan16 (AUTHOR)
Source: Medical Physics. Sep2021, Vol. 48 Issue 9, pe772-e806. 35p.
Subjects: United States. Food & Drug Administration, Physicists, Magnetic resonance imaging, Medical physics, Workflow, Quality assurance
Abstract: Magnetic resonance‐guided focused ultrasound (MRgFUS) is a completely non‐invasive technology that has been approved by FDA to treat several diseases. This report, prepared by the American Association of Physicist in Medicine (AAPM) Task Group 241, provides background on MRgFUS technology with a focus on clinical body MRgFUS systems. The report addresses the issues of interest to the medical physics community, specific to the body MRgFUS system configuration, and provides recommendations on how to successfully implement and maintain a clinical MRgFUS program. The following sections describe the key features of typical MRgFUS systems and clinical workflow and provide key points and best practices for the medical physicist. Commonly used terms, metrics and physics are defined and sources of uncertainty that affect MRgFUS procedures are described. Finally, safety and quality assurance procedures are explained, the recommended role of the medical physicist in MRgFUS procedures is described, and regulatory requirements for planning clinical trials are detailed. Although this report is limited in scope to clinical body MRgFUS systems that are approved or currently undergoing clinical trials in the United States, much of the material presented is also applicable to systems designed for other applications. [ABSTRACT FROM AUTHOR]
Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Links:
  – Type: pdflink
Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 152558777
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: AAPM Task Group 241: A medical physicist's guide to MRI‐guided focused ultrasound body systems.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Payne%2C+Allison%22">Payne, Allison</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Chopra%2C+Rajiv%22">Chopra, Rajiv</searchLink><relatesTo>2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Ellens%2C+Nicholas%22">Ellens, Nicholas</searchLink><relatesTo>3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Chen%2C+Lili%22">Chen, Lili</searchLink><relatesTo>4</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Ghanouni%2C+Pejman%22">Ghanouni, Pejman</searchLink><relatesTo>5</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Sammet%2C+Steffen%22">Sammet, Steffen</searchLink><relatesTo>6</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Diederich%2C+Chris%22">Diederich, Chris</searchLink><relatesTo>7</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22ter+Haar%2C+Gail%22">ter Haar, Gail</searchLink><relatesTo>8</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Parker%2C+Dennis%22">Parker, Dennis</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Moonen%2C+Chrit%22">Moonen, Chrit</searchLink><relatesTo>9</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Stafford%2C+Jason%22">Stafford, Jason</searchLink><relatesTo>10</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Moros%2C+Eduardo%22">Moros, Eduardo</searchLink><relatesTo>11</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Schlesinger%2C+David%22">Schlesinger, David</searchLink><relatesTo>12</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Benedict%2C+Stanley%22">Benedict, Stanley</searchLink><relatesTo>13</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Wear%2C+Keith%22">Wear, Keith</searchLink><relatesTo>14</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Partanen%2C+Ari%22">Partanen, Ari</searchLink><relatesTo>15</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Farahani%2C+Keyvan%22">Farahani, Keyvan</searchLink><relatesTo>16</relatesTo> (AUTHOR)
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Medical+Physics%22">Medical Physics</searchLink>. Sep2021, Vol. 48 Issue 9, pe772-e806. 35p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22United+States%2E+Food+%26+Drug+Administration%22">United States. Food & Drug Administration</searchLink><br /><searchLink fieldCode="DE" term="%22Physicists%22">Physicists</searchLink><br /><searchLink fieldCode="DE" term="%22Magnetic+resonance+imaging%22">Magnetic resonance imaging</searchLink><br /><searchLink fieldCode="DE" term="%22Medical+physics%22">Medical physics</searchLink><br /><searchLink fieldCode="DE" term="%22Workflow%22">Workflow</searchLink><br /><searchLink fieldCode="DE" term="%22Quality+assurance%22">Quality assurance</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Magnetic resonance‐guided focused ultrasound (MRgFUS) is a completely non‐invasive technology that has been approved by FDA to treat several diseases. This report, prepared by the American Association of Physicist in Medicine (AAPM) Task Group 241, provides background on MRgFUS technology with a focus on clinical body MRgFUS systems. The report addresses the issues of interest to the medical physics community, specific to the body MRgFUS system configuration, and provides recommendations on how to successfully implement and maintain a clinical MRgFUS program. The following sections describe the key features of typical MRgFUS systems and clinical workflow and provide key points and best practices for the medical physicist. Commonly used terms, metrics and physics are defined and sources of uncertainty that affect MRgFUS procedures are described. Finally, safety and quality assurance procedures are explained, the recommended role of the medical physicist in MRgFUS procedures is described, and regulatory requirements for planning clinical trials are detailed. Although this report is limited in scope to clinical body MRgFUS systems that are approved or currently undergoing clinical trials in the United States, much of the material presented is also applicable to systems designed for other applications. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=152558777
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1002/mp.15076
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 35
        StartPage: e772
    Subjects:
      – SubjectFull: United States. Food & Drug Administration
        Type: general
      – SubjectFull: Physicists
        Type: general
      – SubjectFull: Magnetic resonance imaging
        Type: general
      – SubjectFull: Medical physics
        Type: general
      – SubjectFull: Workflow
        Type: general
      – SubjectFull: Quality assurance
        Type: general
    Titles:
      – TitleFull: AAPM Task Group 241: A medical physicist's guide to MRI‐guided focused ultrasound body systems.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Payne, Allison
      – PersonEntity:
          Name:
            NameFull: Chopra, Rajiv
      – PersonEntity:
          Name:
            NameFull: Ellens, Nicholas
      – PersonEntity:
          Name:
            NameFull: Chen, Lili
      – PersonEntity:
          Name:
            NameFull: Ghanouni, Pejman
      – PersonEntity:
          Name:
            NameFull: Sammet, Steffen
      – PersonEntity:
          Name:
            NameFull: Diederich, Chris
      – PersonEntity:
          Name:
            NameFull: ter Haar, Gail
      – PersonEntity:
          Name:
            NameFull: Parker, Dennis
      – PersonEntity:
          Name:
            NameFull: Moonen, Chrit
      – PersonEntity:
          Name:
            NameFull: Stafford, Jason
      – PersonEntity:
          Name:
            NameFull: Moros, Eduardo
      – PersonEntity:
          Name:
            NameFull: Schlesinger, David
      – PersonEntity:
          Name:
            NameFull: Benedict, Stanley
      – PersonEntity:
          Name:
            NameFull: Wear, Keith
      – PersonEntity:
          Name:
            NameFull: Partanen, Ari
      – PersonEntity:
          Name:
            NameFull: Farahani, Keyvan
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 09
              Text: Sep2021
              Type: published
              Y: 2021
          Identifiers:
            – Type: issn-print
              Value: 00942405
          Numbering:
            – Type: volume
              Value: 48
            – Type: issue
              Value: 9
          Titles:
            – TitleFull: Medical Physics
              Type: main
ResultId 1