Materials for optical oxygen sensing under high hydrostatic pressure.
Saved in:
| Title: | Materials for optical oxygen sensing under high hydrostatic pressure. |
|---|---|
| Authors: | Dalfen, I.1 (AUTHOR), Burger, T.1 (AUTHOR), Slugovc, C.2 (AUTHOR), Borisov, S.M.1 (AUTHOR) sergey.borisov@tugraz.at, Klimant, I.1 (AUTHOR) |
| Source: | Sensors & Actuators B: Chemical. Feb2022:Part 1, Vol. 352, pN.PAG-N.PAG. 1p. |
| Subjects: | Hydrostatic pressure, Optical materials, Metalloporphyrins, Porous materials, Oxygen detectors, Pressure sensors, Silica gel, Hydrogels |
| Abstract: | Optical oxygen sensors based on indicators immobilized into porous and nonporous matrix materials were investigated in regard to their sensing behaviour under high hydrostatic pressure. The sensors were subjected to step-wise pressure increase up to approximately 200 bar in multiple cycles using a custom-made chamber. The investigated materials are based on oxygen indicators (a platinum(II) benzoporphyrin dye and ruthenium(II) polypyridyl complexes) immobilized in microparticles: silica gels of different porosities, controlled pore glass, poly(phenylsilsesquioxane), crosslinked polystyrene, the metal-organic frameworks ZIF-8 and UiO-66. The microparticles are in turn dispersed in highly oxygen-permeable silicone and Hyflon AD matrices. Homogeneous films of dye doped polystyrene and polyurethane hydrogels as well as non-porous polystyrene nanospheres directly dispersed in water were used for comparison purposes. All the porous materials were found to be stable under elevated hydrostatic pressure. Although the actual oxygen concentration remained unchanged upon increasing pressure, the sensors demonstrated an apparent decrease of calculated oxygen concentration (between −0.02 and −0.45 mg O2 L-1 H 2 O per 100 bar), which was fully reversible. Furthermore, the kinetics of the pressure response of the sensors was determined in experiments with high temporal resolution. Spikes attributed to pressure-induced oxygen diffusion between sensor components were observed within the first seconds after pressurization/depressurization. [Display omitted] • Optical oxygen sensors systematically underestimate O2 concentrations at elevated hydrostatic pressure. • This measurement error strongly depends on the components of the sensor material. • Calculated O 2 concentration linearly depends on hydrostatic pressure which allows for straightforward correction. • At short timescales, a complex interplay of pressure effects is visible in the sensor response. • The investigated porous sensor materials show high stability up to at least 200 bar hydrostatic pressure. [ABSTRACT FROM AUTHOR] |
| Copyright of Sensors & Actuators B: Chemical is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
Be the first to leave a comment!