One view or two views for wide-angle tomosynthesis with synthetic mammography in the assessment setting?
Saved in:
| Title: | One view or two views for wide-angle tomosynthesis with synthetic mammography in the assessment setting? |
|---|---|
| Authors: | Clauser, Paola1 (AUTHOR) clauser.p@hotmail.it, Baltzer, Pascal A. T.1 (AUTHOR), Kapetas, Panagiotis1 (AUTHOR), Woitek, Ramona1 (AUTHOR), Weber, Michael2 (AUTHOR), Leone, Federica3 (AUTHOR), Bernathova, Maria1 (AUTHOR), Helbich, Thomas H.1 (AUTHOR) |
| Source: | European Radiology. Jan2022, Vol. 32 Issue 1, p661-670. 10p. 2 Black and White Photographs, 5 Charts. |
| Subjects: | Tomosynthesis, Digital mammography, Mammograms |
| Abstract: | Objectives: To evaluate the diagnostic performance in the assessment setting of three protocols: one-view wide-angle digital breast tomosynthesis (WA-DBT) with synthetic mammography (SM), two-view WA-DBT/SM, and two-view digital mammography (DM). Methods: Included in this retrospective study were patients who underwent bilateral two-view DM and WA-DBT. SM were reconstructed from the WA-DBT data. The standard of reference was histology and/or 2 years follow-up. Included were 205 women with 179 lesions (89 malignant, 90 benign). Four blinded readers randomly evaluated images to assess density, lesion type, and level of suspicion according to BI-RADS. Three protocols were evaluated: two-view DM, one-view (mediolateral oblique) WA-DBT/SM, and two-view WA-DBT/SM. Detection rate, sensitivity, specificity, and accuracy were calculated and compared using multivariate analysis. Reading time was assessed. Results: The detection rate was higher with two-view WA-DBT/SM (p = 0.063). Sensitivity was higher for two-view WA-DBT/SM compared to two-view DM (p = 0.001) and one-view WA-DBT/SM (p = 0.058). No significant differences in specificity were found. Accuracy was higher with both one-view WA-DBT/SM and two-view WA-DBT/SM compared to DM (p = 0.003 and > 0.001, respectively). Accuracy did not differ between one- and two-view WA-DBT/SM. Two-view WA-DBT/SM performed better for masses and asymmetries. Reading times were significantly longer when WA-DBT was evaluated. Conclusions: One-view and two-view WA-DBT/SM can achieve a higher diagnostic performance compared to two-view DM. The detection rate and sensitivity were highest with two-view WA-DBT/SM. Two-view WA-DBT/SM appears to be the most appropriate tool for the assessment of breast lesions. Key Points: • Detection rate with two-view wide-angle digital breast tomosynthesis (WA-DBT) is significantly higher than with two-view digital mammography in the assessment setting. • Diagnostic accuracy of one-view and two-view WA-DBT with synthetic mammography (SM) in the assessment setting is higher than that of two-view digital mammography. • Compared to one-view WA-DBT with SM, two-view WA-DBT with SM seems to be the most appropriate tool for the assessment of breast lesions. [ABSTRACT FROM AUTHOR] |
| Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
| FullText | Links: – Type: pdflink Text: Availability: 0 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 154043517 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: One view or two views for wide-angle tomosynthesis with synthetic mammography in the assessment setting? – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Clauser%2C+Paola%22">Clauser, Paola</searchLink><relatesTo>1</relatesTo> (AUTHOR)<i> clauser.p@hotmail.it</i><br /><searchLink fieldCode="AR" term="%22Baltzer%2C+Pascal+A%2E+T%2E%22">Baltzer, Pascal A. T.</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Kapetas%2C+Panagiotis%22">Kapetas, Panagiotis</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Woitek%2C+Ramona%22">Woitek, Ramona</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Weber%2C+Michael%22">Weber, Michael</searchLink><relatesTo>2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Leone%2C+Federica%22">Leone, Federica</searchLink><relatesTo>3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Bernathova%2C+Maria%22">Bernathova, Maria</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Helbich%2C+Thomas+H%2E%22">Helbich, Thomas H.</searchLink><relatesTo>1</relatesTo> (AUTHOR) – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22European+Radiology%22">European Radiology</searchLink>. Jan2022, Vol. 32 Issue 1, p661-670. 10p. 2 Black and White Photographs, 5 Charts. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22Tomosynthesis%22">Tomosynthesis</searchLink><br /><searchLink fieldCode="DE" term="%22Digital+mammography%22">Digital mammography</searchLink><br /><searchLink fieldCode="DE" term="%22Mammograms%22">Mammograms</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: Objectives: To evaluate the diagnostic performance in the assessment setting of three protocols: one-view wide-angle digital breast tomosynthesis (WA-DBT) with synthetic mammography (SM), two-view WA-DBT/SM, and two-view digital mammography (DM). Methods: Included in this retrospective study were patients who underwent bilateral two-view DM and WA-DBT. SM were reconstructed from the WA-DBT data. The standard of reference was histology and/or 2 years follow-up. Included were 205 women with 179 lesions (89 malignant, 90 benign). Four blinded readers randomly evaluated images to assess density, lesion type, and level of suspicion according to BI-RADS. Three protocols were evaluated: two-view DM, one-view (mediolateral oblique) WA-DBT/SM, and two-view WA-DBT/SM. Detection rate, sensitivity, specificity, and accuracy were calculated and compared using multivariate analysis. Reading time was assessed. Results: The detection rate was higher with two-view WA-DBT/SM (p = 0.063). Sensitivity was higher for two-view WA-DBT/SM compared to two-view DM (p = 0.001) and one-view WA-DBT/SM (p = 0.058). No significant differences in specificity were found. Accuracy was higher with both one-view WA-DBT/SM and two-view WA-DBT/SM compared to DM (p = 0.003 and > 0.001, respectively). Accuracy did not differ between one- and two-view WA-DBT/SM. Two-view WA-DBT/SM performed better for masses and asymmetries. Reading times were significantly longer when WA-DBT was evaluated. Conclusions: One-view and two-view WA-DBT/SM can achieve a higher diagnostic performance compared to two-view DM. The detection rate and sensitivity were highest with two-view WA-DBT/SM. Two-view WA-DBT/SM appears to be the most appropriate tool for the assessment of breast lesions. Key Points: • Detection rate with two-view wide-angle digital breast tomosynthesis (WA-DBT) is significantly higher than with two-view digital mammography in the assessment setting. • Diagnostic accuracy of one-view and two-view WA-DBT with synthetic mammography (SM) in the assessment setting is higher than that of two-view digital mammography. • Compared to one-view WA-DBT with SM, two-view WA-DBT with SM seems to be the most appropriate tool for the assessment of breast lesions. [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=154043517 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1007/s00330-021-08079-2 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 10 StartPage: 661 Subjects: – SubjectFull: Tomosynthesis Type: general – SubjectFull: Digital mammography Type: general – SubjectFull: Mammograms Type: general Titles: – TitleFull: One view or two views for wide-angle tomosynthesis with synthetic mammography in the assessment setting? Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Clauser, Paola – PersonEntity: Name: NameFull: Baltzer, Pascal A. T. – PersonEntity: Name: NameFull: Kapetas, Panagiotis – PersonEntity: Name: NameFull: Woitek, Ramona – PersonEntity: Name: NameFull: Weber, Michael – PersonEntity: Name: NameFull: Leone, Federica – PersonEntity: Name: NameFull: Bernathova, Maria – PersonEntity: Name: NameFull: Helbich, Thomas H. IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 01 Text: Jan2022 Type: published Y: 2022 Identifiers: – Type: issn-print Value: 09387994 Numbering: – Type: volume Value: 32 – Type: issue Value: 1 Titles: – TitleFull: European Radiology Type: main |
| ResultId | 1 |