Calibration methods for charge integrating detectors.

Saved in:
Bibliographic Details
Title: Calibration methods for charge integrating detectors.
Authors: Mezza, D.1 (AUTHOR) davide.mezza@psi.ch, Becker, J.2 (AUTHOR), Carraresi, L.3,4 (AUTHOR), Castoldi, A.5,6 (AUTHOR), Dinapoli, R.1 (AUTHOR), Goettlicher, P.7 (AUTHOR), Graafsma, H.7,8 (AUTHOR), Greiffenberg, D.1 (AUTHOR), Hirsemann, H.7 (AUTHOR), Klujev, A.7 (AUTHOR), Kuhn, M.7 (AUTHOR), Lange, S.7 (AUTHOR), Laurus, T.7 (AUTHOR), Maffessanti, S.7 (AUTHOR), Marras, A.7 (AUTHOR), Mozzanica, A.1 (AUTHOR), Poehlsen, J.7 (AUTHOR), Redford, S.1 (AUTHOR), Ruder, C.1 (AUTHOR), Schmitt, B.1 (AUTHOR)
Source: Nuclear Instruments & Methods in Physics Research Section A. Feb2022, Vol. 1024, pN.PAG-N.PAG. 1p.
Subjects: Free electron lasers, Detectors, Calibration, Nuclear counters, Radiation tolerance
Abstract: Since the introduction of the extremely intense X-ray free electron lasers, the need for low noise, high dynamic range and potentially fast charge integrating detectors has increased significantly. Among all the problems that research and development groups have to face in the development of such detectors, their calibration represents one of the most challenging and the collaboration between the detector development and user groups is of fundamental importance. The main challenge is to develop a calibration suite that is capable to test the detector over a wide dynamic range, with a high granularity and a very high linearity, together with a certain radiation tolerance and the possibility to well define the timings and the synchronization with the detector. Practical considerations have also to be made like the possibility to calibrate the detector in a reasonable time, the availability of the calibration source at the experimental place and so on. Such a calibration test suite is often not represented by a single source but by several sources that can cover different parts of the dynamic range and that need to be cross calibrated to have a final calibration curve. In this respect an essential part of the calibration is also to develop a mathematical model that allows calibrating the entire dynamic range, taking into account features that are calibration source and/or detector specific. The aim of this contribution is to compare the calibration for the AGIPD detector using several calibration sources such as internal current source, backside pulsing, IR pulsed laser, LED light and mono-energetic protons. The mathematical procedure used to calibrate the different sources will be discussed in great detail showing how to take into account a few shortcomings (like pixel coupling) that are common for many charge integrating detectors. This work has been carried out in the frame of the AGIPD project for the European X-ray Free Electron Laser. [ABSTRACT FROM AUTHOR]
Copyright of Nuclear Instruments & Methods in Physics Research Section A is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 154435798
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Calibration methods for charge integrating detectors.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Mezza%2C+D%2E%22">Mezza, D.</searchLink><relatesTo>1</relatesTo> (AUTHOR)<i> davide.mezza@psi.ch</i><br /><searchLink fieldCode="AR" term="%22Becker%2C+J%2E%22">Becker, J.</searchLink><relatesTo>2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Carraresi%2C+L%2E%22">Carraresi, L.</searchLink><relatesTo>3,4</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Castoldi%2C+A%2E%22">Castoldi, A.</searchLink><relatesTo>5,6</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Dinapoli%2C+R%2E%22">Dinapoli, R.</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Goettlicher%2C+P%2E%22">Goettlicher, P.</searchLink><relatesTo>7</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Graafsma%2C+H%2E%22">Graafsma, H.</searchLink><relatesTo>7,8</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Greiffenberg%2C+D%2E%22">Greiffenberg, D.</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Hirsemann%2C+H%2E%22">Hirsemann, H.</searchLink><relatesTo>7</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Klujev%2C+A%2E%22">Klujev, A.</searchLink><relatesTo>7</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Kuhn%2C+M%2E%22">Kuhn, M.</searchLink><relatesTo>7</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Lange%2C+S%2E%22">Lange, S.</searchLink><relatesTo>7</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Laurus%2C+T%2E%22">Laurus, T.</searchLink><relatesTo>7</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Maffessanti%2C+S%2E%22">Maffessanti, S.</searchLink><relatesTo>7</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Marras%2C+A%2E%22">Marras, A.</searchLink><relatesTo>7</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Mozzanica%2C+A%2E%22">Mozzanica, A.</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Poehlsen%2C+J%2E%22">Poehlsen, J.</searchLink><relatesTo>7</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Redford%2C+S%2E%22">Redford, S.</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Ruder%2C+C%2E%22">Ruder, C.</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Schmitt%2C+B%2E%22">Schmitt, B.</searchLink><relatesTo>1</relatesTo> (AUTHOR)
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Nuclear+Instruments+%26+Methods+in+Physics+Research+Section+A%22">Nuclear Instruments & Methods in Physics Research Section A</searchLink>. Feb2022, Vol. 1024, pN.PAG-N.PAG. 1p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Free+electron+lasers%22">Free electron lasers</searchLink><br /><searchLink fieldCode="DE" term="%22Detectors%22">Detectors</searchLink><br /><searchLink fieldCode="DE" term="%22Calibration%22">Calibration</searchLink><br /><searchLink fieldCode="DE" term="%22Nuclear+counters%22">Nuclear counters</searchLink><br /><searchLink fieldCode="DE" term="%22Radiation+tolerance%22">Radiation tolerance</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Since the introduction of the extremely intense X-ray free electron lasers, the need for low noise, high dynamic range and potentially fast charge integrating detectors has increased significantly. Among all the problems that research and development groups have to face in the development of such detectors, their calibration represents one of the most challenging and the collaboration between the detector development and user groups is of fundamental importance. The main challenge is to develop a calibration suite that is capable to test the detector over a wide dynamic range, with a high granularity and a very high linearity, together with a certain radiation tolerance and the possibility to well define the timings and the synchronization with the detector. Practical considerations have also to be made like the possibility to calibrate the detector in a reasonable time, the availability of the calibration source at the experimental place and so on. Such a calibration test suite is often not represented by a single source but by several sources that can cover different parts of the dynamic range and that need to be cross calibrated to have a final calibration curve. In this respect an essential part of the calibration is also to develop a mathematical model that allows calibrating the entire dynamic range, taking into account features that are calibration source and/or detector specific. The aim of this contribution is to compare the calibration for the AGIPD detector using several calibration sources such as internal current source, backside pulsing, IR pulsed laser, LED light and mono-energetic protons. The mathematical procedure used to calibrate the different sources will be discussed in great detail showing how to take into account a few shortcomings (like pixel coupling) that are common for many charge integrating detectors. This work has been carried out in the frame of the AGIPD project for the European X-ray Free Electron Laser. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Nuclear Instruments & Methods in Physics Research Section A is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=154435798
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1016/j.nima.2021.166078
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 1
        StartPage: N.PAG
    Subjects:
      – SubjectFull: Free electron lasers
        Type: general
      – SubjectFull: Detectors
        Type: general
      – SubjectFull: Calibration
        Type: general
      – SubjectFull: Nuclear counters
        Type: general
      – SubjectFull: Radiation tolerance
        Type: general
    Titles:
      – TitleFull: Calibration methods for charge integrating detectors.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Mezza, D.
      – PersonEntity:
          Name:
            NameFull: Becker, J.
      – PersonEntity:
          Name:
            NameFull: Carraresi, L.
      – PersonEntity:
          Name:
            NameFull: Castoldi, A.
      – PersonEntity:
          Name:
            NameFull: Dinapoli, R.
      – PersonEntity:
          Name:
            NameFull: Goettlicher, P.
      – PersonEntity:
          Name:
            NameFull: Graafsma, H.
      – PersonEntity:
          Name:
            NameFull: Greiffenberg, D.
      – PersonEntity:
          Name:
            NameFull: Hirsemann, H.
      – PersonEntity:
          Name:
            NameFull: Klujev, A.
      – PersonEntity:
          Name:
            NameFull: Kuhn, M.
      – PersonEntity:
          Name:
            NameFull: Lange, S.
      – PersonEntity:
          Name:
            NameFull: Laurus, T.
      – PersonEntity:
          Name:
            NameFull: Maffessanti, S.
      – PersonEntity:
          Name:
            NameFull: Marras, A.
      – PersonEntity:
          Name:
            NameFull: Mozzanica, A.
      – PersonEntity:
          Name:
            NameFull: Poehlsen, J.
      – PersonEntity:
          Name:
            NameFull: Redford, S.
      – PersonEntity:
          Name:
            NameFull: Ruder, C.
      – PersonEntity:
          Name:
            NameFull: Schmitt, B.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 02
              Text: Feb2022
              Type: published
              Y: 2022
          Identifiers:
            – Type: issn-print
              Value: 01689002
          Numbering:
            – Type: volume
              Value: 1024
          Titles:
            – TitleFull: Nuclear Instruments & Methods in Physics Research Section A
              Type: main
ResultId 1