The efficacy of Raman spectroscopy in lung cancer diagnosis: the first diagnostic meta-analysis.
Saved in:
| Title: | The efficacy of Raman spectroscopy in lung cancer diagnosis: the first diagnostic meta-analysis. |
|---|---|
| Authors: | Ke, Zhang-Yan1 (AUTHOR), Ning, Ya-Jing1 (AUTHOR), Jiang, Zi-Feng1 (AUTHOR), Zhu, Ying-ying1 (AUTHOR), Guo, Jia2 (AUTHOR), Fan, Xiao-Yun1 (AUTHOR) 13956988552@163.com, Zhang, Yan-Bei1 (AUTHOR) zhangyanbei1963@126.com |
| Source: | Lasers in Medical Science. Feb2022, Vol. 37 Issue 1, p425-434. 10p. |
| Subjects: | Raman spectroscopy, Lung cancer, Cancer diagnosis, Saliva, Publication bias, Sensitivity & specificity (Statistics) |
| Abstract: | In recent years, many researches have explored the diagnostic value of Raman spectroscopy in multiple types of tumors. However, as an emerging clinical examination method, the diagnostic performance of Raman spectroscopy in lung cancer remains unclear. Relevant diagnostic studies published before 1 June 2020 were retrieved from the Cochrane Library, PubMed, EMBASE, China National Knowledge Internet (CNKI), and WanFang databases. After the literature was screened, two authors extracted the data from eligible studies according to the inclusion and exclusion criteria. Obtained data were pooled and analyzed using Stata 16.0, Meta-DiSc 1.4, and RevMan 5.3 software. Fourteen diagnostic studies were eligible for the pooled analysis which includes 779 patients. Total pooled sensitivity and specificity of Raman spectroscopy in diagnosing lung cancer were 0.92 (95% CI 0.87–0.95) and 0.94 (95% CI 0.88–0.97), respectively. The positive likelihood ratio was 15.2 (95% CI 7.5–30.9), the negative likelihood ratio was 0.09 (95% CI 0.05–0.14), and the area under the curve was 0.97 (95 % CI 0.95–0.98). Subgroup analysis suggested that the sensitivity and specificity of RS when analyzing human tissue, serum, and saliva samples were 0.95 (95% CI 0.88–0.98), 0.97 (95% CI 0.89–0.99), 0.88 (95% CI 0.80–0.93), 0.87 (95% CI 0.78–0.92), 0.91 (95% CI 0.80–0.96), and 0.95 (95% CI 0.73–0.99), respectively. No publication bias or threshold effects were detected in this meta-analysis. This initial meta-analysis indicated that Raman spectroscopy is a highly specific and sensitive diagnostic technology for detecting lung cancer. Further investigations are also needed to focus on real-time detection using Raman spectroscopy under bronchoscopy in vivo. Moreover, large-scale diagnostic studies should be conducted to confirm this conclusion. [ABSTRACT FROM AUTHOR] |
| Copyright of Lasers in Medical Science is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
|
Full text is not displayed to guests.
Login for full access.
|
|
Be the first to leave a comment!