Methods of monitoring thermal ablation of soft tissue tumors – A comprehensive review.

Saved in:
Bibliographic Details
Title: Methods of monitoring thermal ablation of soft tissue tumors – A comprehensive review.
Authors: Geoghegan, Rory1 (AUTHOR) rory.geoghegan@ucla.edu, ter Haar, Gail2 (AUTHOR), Nightingale, Kathryn3 (AUTHOR), Marks, Leonard1 (AUTHOR), Natarajan, Shyam4 (AUTHOR)
Source: Medical Physics. Feb2022, Vol. 49 Issue 2, p769-791. 23p.
Subjects: Soft tissue tumors, Tissue mechanics, Damage models, Optical properties, Catheter ablation, Tissues
Abstract: Thermal ablation is a form of hyperthermia in which oncologic control can be achieved by briefly inducing elevated temperatures, typically in the range 50–80°C, within a target tissue. Ablation modalities include high intensity focused ultrasound, radiofrequency ablation, microwave ablation, and laser interstitial thermal therapy which are all capable of generating confined zones of tissue destruction, resulting in fewer complications than conventional cancer therapies. Oncologic control is contingent upon achieving predefined coagulation zones; therefore, intraoperative assessment of treatment progress is highly desirable. Consequently, there is a growing interest in the development of ablation monitoring modalities. The first section of this review presents the mechanism of action and common applications of the primary ablation modalities. The following section outlines the state‐of‐the‐art in thermal dosimetry which includes interstitial thermal probes and radiologic imaging. Both the physical mechanism of measurement and clinical or pre‐clinical performance are discussed for each ablation modality. Thermal dosimetry must be coupled with a thermal damage model as outlined in Section 4. These models estimate cell death based on temperature‐time history and are inherently tissue specific. In the absence of a reliable thermal model, the utility of thermal monitoring is greatly reduced. The final section of this review paper covers technologies that have been developed to directly assess tissue conditions. These approaches include visualization of non‐perfused tissue with contrast‐enhanced imaging, assessment of tissue mechanical properties using ultrasound and magnetic resonance elastography, and finally interrogation of tissue optical properties with interstitial probes. In summary, monitoring thermal ablation is critical for consistent clinical success and many promising technologies are under development but an optimal solution has yet to achieve widespread adoption. [ABSTRACT FROM AUTHOR]
Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Full text is not displayed to guests.
FullText Links:
  – Type: pdflink
Text:
  Availability: 1
Header DbId: egs
DbLabel: Engineering Source
An: 155147397
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Methods of monitoring thermal ablation of soft tissue tumors – A comprehensive review.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Geoghegan%2C+Rory%22">Geoghegan, Rory</searchLink><relatesTo>1</relatesTo> (AUTHOR)<i> rory.geoghegan@ucla.edu</i><br /><searchLink fieldCode="AR" term="%22ter+Haar%2C+Gail%22">ter Haar, Gail</searchLink><relatesTo>2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Nightingale%2C+Kathryn%22">Nightingale, Kathryn</searchLink><relatesTo>3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Marks%2C+Leonard%22">Marks, Leonard</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Natarajan%2C+Shyam%22">Natarajan, Shyam</searchLink><relatesTo>4</relatesTo> (AUTHOR)
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Medical+Physics%22">Medical Physics</searchLink>. Feb2022, Vol. 49 Issue 2, p769-791. 23p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Soft+tissue+tumors%22">Soft tissue tumors</searchLink><br /><searchLink fieldCode="DE" term="%22Tissue+mechanics%22">Tissue mechanics</searchLink><br /><searchLink fieldCode="DE" term="%22Damage+models%22">Damage models</searchLink><br /><searchLink fieldCode="DE" term="%22Optical+properties%22">Optical properties</searchLink><br /><searchLink fieldCode="DE" term="%22Catheter+ablation%22">Catheter ablation</searchLink><br /><searchLink fieldCode="DE" term="%22Tissues%22">Tissues</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Thermal ablation is a form of hyperthermia in which oncologic control can be achieved by briefly inducing elevated temperatures, typically in the range 50–80°C, within a target tissue. Ablation modalities include high intensity focused ultrasound, radiofrequency ablation, microwave ablation, and laser interstitial thermal therapy which are all capable of generating confined zones of tissue destruction, resulting in fewer complications than conventional cancer therapies. Oncologic control is contingent upon achieving predefined coagulation zones; therefore, intraoperative assessment of treatment progress is highly desirable. Consequently, there is a growing interest in the development of ablation monitoring modalities. The first section of this review presents the mechanism of action and common applications of the primary ablation modalities. The following section outlines the state‐of‐the‐art in thermal dosimetry which includes interstitial thermal probes and radiologic imaging. Both the physical mechanism of measurement and clinical or pre‐clinical performance are discussed for each ablation modality. Thermal dosimetry must be coupled with a thermal damage model as outlined in Section 4. These models estimate cell death based on temperature‐time history and are inherently tissue specific. In the absence of a reliable thermal model, the utility of thermal monitoring is greatly reduced. The final section of this review paper covers technologies that have been developed to directly assess tissue conditions. These approaches include visualization of non‐perfused tissue with contrast‐enhanced imaging, assessment of tissue mechanical properties using ultrasound and magnetic resonance elastography, and finally interrogation of tissue optical properties with interstitial probes. In summary, monitoring thermal ablation is critical for consistent clinical success and many promising technologies are under development but an optimal solution has yet to achieve widespread adoption. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=155147397
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1002/mp.15439
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 23
        StartPage: 769
    Subjects:
      – SubjectFull: Soft tissue tumors
        Type: general
      – SubjectFull: Tissue mechanics
        Type: general
      – SubjectFull: Damage models
        Type: general
      – SubjectFull: Optical properties
        Type: general
      – SubjectFull: Catheter ablation
        Type: general
      – SubjectFull: Tissues
        Type: general
    Titles:
      – TitleFull: Methods of monitoring thermal ablation of soft tissue tumors – A comprehensive review.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Geoghegan, Rory
      – PersonEntity:
          Name:
            NameFull: ter Haar, Gail
      – PersonEntity:
          Name:
            NameFull: Nightingale, Kathryn
      – PersonEntity:
          Name:
            NameFull: Marks, Leonard
      – PersonEntity:
          Name:
            NameFull: Natarajan, Shyam
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 02
              Text: Feb2022
              Type: published
              Y: 2022
          Identifiers:
            – Type: issn-print
              Value: 00942405
          Numbering:
            – Type: volume
              Value: 49
            – Type: issue
              Value: 2
          Titles:
            – TitleFull: Medical Physics
              Type: main
ResultId 1