ID23‐2: an automated and high‐performance microfocus beamline for macromolecular crystallography at the ESRF.
Saved in:
| Title: | ID23‐2: an automated and high‐performance microfocus beamline for macromolecular crystallography at the ESRF. |
|---|---|
| Authors: | Nanao, Max1 (AUTHOR) max.nanao@esrf.fr, Basu, Shibom2 (AUTHOR), Zander, Ulrich2 (AUTHOR), Giraud, Thierry1 (AUTHOR), Surr, John1 (AUTHOR), Guijarro, Matias1 (AUTHOR), Lentini, Mario1 (AUTHOR), Felisaz, Franck2 (AUTHOR), Sinoir, Jeremy2 (AUTHOR), Morawe, Christian1 (AUTHOR), Vivo, Amparo1 (AUTHOR), Beteva, Antonia1 (AUTHOR), Oscarsson, Marcus1 (AUTHOR), Caserotto, Hugo1 (AUTHOR), Dobias, Fabien1 (AUTHOR), Flot, David1 (AUTHOR), Nurizzo, Didier1 (AUTHOR), Gigmes, Jonathan1 (AUTHOR), Foos, Nicolas1 (AUTHOR), Siebrecht, Ralf3 (AUTHOR) |
| Source: | Journal of Synchrotron Radiation. Mar2022, Vol. 29 Issue 2, p581-590. 10p. |
| Subjects: | Crystallography, Synchrotron radiation, Data reduction, Optics, Diffractometers |
| Abstract: | ID23‐2 is a fixed‐energy (14.2 keV) microfocus beamline at the European Synchrotron Radiation Facility (ESRF) dedicated to macromolecular crystallography. The optics and sample environment have recently been redesigned and rebuilt to take full advantage of the upgrade of the ESRF to the fourth generation Extremely Brilliant Source (ESRF‐EBS). The upgraded beamline now makes use of two sets of compound refractive lenses and multilayer mirrors to obtain a highly intense (>1013 photons s−1) focused microbeam (minimum size 1.5 µm × 3 µm full width at half‐maximum). The sample environment now includes a FLEX‐HCD sample changer/storage system, as well as a state‐of‐the‐art MD3Up high‐precision multi‐axis diffractometer. Automatic data reduction and analysis are also provided for more advanced protocols such as synchrotron serial crystallographic experiments. [ABSTRACT FROM AUTHOR] |
| Copyright of Journal of Synchrotron Radiation is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
|
Full text is not displayed to guests.
Login for full access.
|
|
| Abstract: | ID23‐2 is a fixed‐energy (14.2 keV) microfocus beamline at the European Synchrotron Radiation Facility (ESRF) dedicated to macromolecular crystallography. The optics and sample environment have recently been redesigned and rebuilt to take full advantage of the upgrade of the ESRF to the fourth generation Extremely Brilliant Source (ESRF‐EBS). The upgraded beamline now makes use of two sets of compound refractive lenses and multilayer mirrors to obtain a highly intense (>1013 photons s−1) focused microbeam (minimum size 1.5 µm × 3 µm full width at half‐maximum). The sample environment now includes a FLEX‐HCD sample changer/storage system, as well as a state‐of‐the‐art MD3Up high‐precision multi‐axis diffractometer. Automatic data reduction and analysis are also provided for more advanced protocols such as synchrotron serial crystallographic experiments. [ABSTRACT FROM AUTHOR] |
|---|---|
| ISSN: | 09090495 |