Myocardial T1, T2, T2*, and fat fraction quantification via low‐rank motion‐corrected cardiac MR fingerprinting.

Saved in:
Bibliographic Details
Title: Myocardial T1, T2, T2*, and fat fraction quantification via low‐rank motion‐corrected cardiac MR fingerprinting.
Authors: Lima da Cruz, Gastao José1 (AUTHOR) gastao.cruz@kcl.ac.uk, Velasco, Carlos1 (AUTHOR), Lavin, Begoña1,2 (AUTHOR), Jaubert, Olivier1 (AUTHOR), Botnar, Rene Michael1,3 (AUTHOR), Prieto, Claudia1,3 (AUTHOR)
Source: Magnetic Resonance in Medicine. Jun2022, Vol. 87 Issue 6, p2757-2774. 18p.
Subjects: Fat, Magnetic resonance imaging
Abstract: Purpose: Develop a novel 2D cardiac MR fingerprinting (MRF) approach to enable simultaneous T1, T2, T2*, and fat fraction (FF) myocardial tissue characterization in a single breath‐hold scan. Methods: Simultaneous, co‐registered, multi‐parametric mapping of T1, T2, and FF has been recently achieved with cardiac MRF. Here, we further incorporate T2* quantification within this approach, enabling simultaneous T1, T2, T2*, and FF myocardial tissue characterization in a single breath‐hold scan. T2* quantification is achieved with an eight‐echo readout that requires a long cardiac acquisition window. A novel low‐rank motion‐corrected (LRMC) reconstruction is exploited to correct for cardiac motion within the long acquisition window. The proposed T1/T2/T2*/FF cardiac MRF was evaluated in phantom and in 10 healthy subjects in comparison to conventional mapping techniques. Results: The proposed approach achieved high quality parametric mapping of T1, T2, T2*, and FF with corresponding normalized RMS error (RMSE) T1 = 5.9%, T2 = 9.6% (T2 values <100 ms), T2* = 3.3% (T2* values <100 ms), and FF = 0.8% observed in phantom scans. In vivo, the proposed approach produced higher left‐ventricular myocardial T1 values than MOLLI (1148 vs 1056 ms), lower T2 values than T2‐GraSE (42.8 vs 50.6 ms), lower T2* values than eight‐echo gradient echo (GRE) (35.0 vs 39.4 ms), and higher FF values than six‐echo GRE (0.8 vs 0.3 %) reference techniques. The proposed approach achieved considerable reduction in motion artifacts compared to cardiac MRF without motion correction, improved spatial uniformity, and statistically higher apparent precision relative to conventional mapping for all parameters. Conclusion: The proposed cardiac MRF approach enables simultaneous, co‐registered mapping of T1, T2, T2*, and FF in a single breath‐hold for comprehensive myocardial tissue characterization, achieving higher apparent precision than conventional methods. [ABSTRACT FROM AUTHOR]
Copyright of Magnetic Resonance in Medicine is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Full text is not displayed to guests.
FullText Links:
  – Type: pdflink
Text:
  Availability: 1
Header DbId: egs
DbLabel: Engineering Source
An: 155950702
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Myocardial T1, T2, T2*, and fat fraction quantification via low‐rank motion‐corrected cardiac MR fingerprinting.
– Name: Author
  Label: Authors
  Group: Au
  Data: &lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Lima+da+Cruz%2C+Gastao+Jos&#233;%22&quot;&gt;Lima da Cruz, Gastao Jos&#233;&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt; (AUTHOR)&lt;i&gt; gastao.cruz@kcl.ac.uk&lt;/i&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Velasco%2C+Carlos%22&quot;&gt;Velasco, Carlos&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Lavin%2C+Bego&#241;a%22&quot;&gt;Lavin, Bego&#241;a&lt;/searchLink&gt;&lt;relatesTo&gt;1,2&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Jaubert%2C+Olivier%22&quot;&gt;Jaubert, Olivier&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Botnar%2C+Rene+Michael%22&quot;&gt;Botnar, Rene Michael&lt;/searchLink&gt;&lt;relatesTo&gt;1,3&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Prieto%2C+Claudia%22&quot;&gt;Prieto, Claudia&lt;/searchLink&gt;&lt;relatesTo&gt;1,3&lt;/relatesTo&gt; (AUTHOR)
– Name: TitleSource
  Label: Source
  Group: Src
  Data: &lt;searchLink fieldCode=&quot;JN&quot; term=&quot;%22Magnetic+Resonance+in+Medicine%22&quot;&gt;Magnetic Resonance in Medicine&lt;/searchLink&gt;. Jun2022, Vol. 87 Issue 6, p2757-2774. 18p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: &lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Fat%22&quot;&gt;Fat&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Magnetic+resonance+imaging%22&quot;&gt;Magnetic resonance imaging&lt;/searchLink&gt;
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Purpose: Develop a novel 2D cardiac MR fingerprinting (MRF) approach to enable simultaneous T1, T2, T2*, and fat fraction (FF) myocardial tissue characterization in a single breath‐hold scan. Methods: Simultaneous, co‐registered, multi‐parametric mapping of T1, T2, and FF has been recently achieved with cardiac MRF. Here, we further incorporate T2* quantification within this approach, enabling simultaneous T1, T2, T2*, and FF myocardial tissue characterization in a single breath‐hold scan. T2* quantification is achieved with an eight‐echo readout that requires a long cardiac acquisition window. A novel low‐rank motion‐corrected (LRMC) reconstruction is exploited to correct for cardiac motion within the long acquisition window. The proposed T1/T2/T2*/FF cardiac MRF was evaluated in phantom and in 10 healthy subjects in comparison to conventional mapping techniques. Results: The proposed approach achieved high quality parametric mapping of T1, T2, T2*, and FF with corresponding normalized RMS error (RMSE) T1 = 5.9%, T2 = 9.6% (T2 values &lt;100 ms), T2* = 3.3% (T2* values &lt;100 ms), and FF = 0.8% observed in phantom scans. In vivo, the proposed approach produced higher left‐ventricular myocardial T1 values than MOLLI (1148 vs 1056 ms), lower T2 values than T2‐GraSE (42.8 vs 50.6 ms), lower T2* values than eight‐echo gradient echo (GRE) (35.0 vs 39.4 ms), and higher FF values than six‐echo GRE (0.8 vs 0.3 %) reference techniques. The proposed approach achieved considerable reduction in motion artifacts compared to cardiac MRF without motion correction, improved spatial uniformity, and statistically higher apparent precision relative to conventional mapping for all parameters. Conclusion: The proposed cardiac MRF approach enables simultaneous, co‐registered mapping of T1, T2, T2*, and FF in a single breath‐hold for comprehensive myocardial tissue characterization, achieving higher apparent precision than conventional methods. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: &lt;i&gt;Copyright of Magnetic Resonance in Medicine is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder&#39;s express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.&lt;/i&gt; (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=155950702
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1002/mrm.29171
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 18
        StartPage: 2757
    Subjects:
      – SubjectFull: Fat
        Type: general
      – SubjectFull: Magnetic resonance imaging
        Type: general
    Titles:
      – TitleFull: Myocardial T1, T2, T2*, and fat fraction quantification via low‐rank motion‐corrected cardiac MR fingerprinting.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Lima da Cruz, Gastao José
      – PersonEntity:
          Name:
            NameFull: Velasco, Carlos
      – PersonEntity:
          Name:
            NameFull: Lavin, Begoña
      – PersonEntity:
          Name:
            NameFull: Jaubert, Olivier
      – PersonEntity:
          Name:
            NameFull: Botnar, Rene Michael
      – PersonEntity:
          Name:
            NameFull: Prieto, Claudia
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 06
              Text: Jun2022
              Type: published
              Y: 2022
          Identifiers:
            – Type: issn-print
              Value: 07403194
          Numbering:
            – Type: volume
              Value: 87
            – Type: issue
              Value: 6
          Titles:
            – TitleFull: Magnetic Resonance in Medicine
              Type: main
ResultId 1