Diuretic-enhanced gadolinium excretory MR urography: comparison of conventional gradient-echo sequences and echo-planar imaging.

Saved in:
Bibliographic Details
Title: Diuretic-enhanced gadolinium excretory MR urography: comparison of conventional gradient-echo sequences and echo-planar imaging.
Authors: Nolte-Ernsting, C. A.1, Tacke, Josef1, Adam, Gerhard B.1, Haage, Patrick1, Jung, Peter2, Jakse, Gerhard2, Günther, Rolf W.1, Nolte-Ernsting, C C3 (AUTHOR), Tacke, J (AUTHOR), Adam, G B (AUTHOR), Haage, P (AUTHOR), Jung, P (AUTHOR), Jakse, G (AUTHOR), Günther, R W (AUTHOR)
Source: European Radiology. Jan2001, Vol. 11 Issue 1, p18-27. 10p.
Subjects: Diuretics, Visual perception, Urinary organs, Gastrointestinal motility, Muscle contraction, Critical care medicine
Abstract: The aim of this study was to investigate the utility of different gadolinium-enhanced T1-weighted gradient-echo techniques in excretory MR urography. In 74 urologic patients, excretory MR urography was performed using various T1-weighted gradient-echo (GRE) sequences after injection of gadolinium-DTPA and low-dose furosemide. The examinations included conventional GRE sequences and echo-planar imaging (GRE EPI), both obtained with 3D data sets and 2D projection images. Breath-hold acquisition was used primarily. In 20 of 74 examinations, we compared breath-hold imaging with respiratory gating. Breath-hold imaging was significantly superior to respiratory gating for the visualization of pelvicaliceal systems, but not for the ureters. Complete MR urograms were obtained within 14-20 s using 3D GRE EPI sequences and in 20-30 s with conventional 3D GRE sequences. Ghost artefacts caused by ureteral peristalsis often occurred with conventional 3D GRE imaging and were almost completely suppressed in EPI sequences (p < 0.0001). Susceptibility effects were more pronounced on GRE EPI MR urograms and calculi measured 0.8-21.7% greater in diameter compared with conventional GRE sequences. Increased spatial resolution degraded the image quality only in GRE-EPI urograms. In projection MR urography, the entire pelvicaliceal system was imaged by acquisition of a fast single-slice sequence and the conventional 2D GRE technique provided superior morphological accuracy than 2D GRE EPI projection images (p < 0.0003). Fast 3D GRE EPI sequences improve the clinical practicability of excretory MR urography especially in old or critically ill patients unable to suspend breathing for more than 20 s. Conventional GRE sequences are superior to EPI in high-resolution detail MR urograms and in projection imaging. [ABSTRACT FROM AUTHOR]
Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Links:
  – Type: pdflink
Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 15654338
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Diuretic-enhanced gadolinium excretory MR urography: comparison of conventional gradient-echo sequences and echo-planar imaging.
– Name: Author
  Label: Authors
  Group: Au
  Data: &lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Nolte-Ernsting%2C+C%2E+A%2E%22&quot;&gt;Nolte-Ernsting, C. A.&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Tacke%2C+Josef%22&quot;&gt;Tacke, Josef&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Adam%2C+Gerhard+B%2E%22&quot;&gt;Adam, Gerhard B.&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Haage%2C+Patrick%22&quot;&gt;Haage, Patrick&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Jung%2C+Peter%22&quot;&gt;Jung, Peter&lt;/searchLink&gt;&lt;relatesTo&gt;2&lt;/relatesTo&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Jakse%2C+Gerhard%22&quot;&gt;Jakse, Gerhard&lt;/searchLink&gt;&lt;relatesTo&gt;2&lt;/relatesTo&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22G&#252;nther%2C+Rolf+W%2E%22&quot;&gt;G&#252;nther, Rolf W.&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Nolte-Ernsting%2C+C+C%22&quot;&gt;Nolte-Ernsting, C C&lt;/searchLink&gt;&lt;relatesTo&gt;3&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Tacke%2C+J%22&quot;&gt;Tacke, J&lt;/searchLink&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Adam%2C+G+B%22&quot;&gt;Adam, G B&lt;/searchLink&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Haage%2C+P%22&quot;&gt;Haage, P&lt;/searchLink&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Jung%2C+P%22&quot;&gt;Jung, P&lt;/searchLink&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Jakse%2C+G%22&quot;&gt;Jakse, G&lt;/searchLink&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22G&#252;nther%2C+R+W%22&quot;&gt;G&#252;nther, R W&lt;/searchLink&gt; (AUTHOR)
– Name: TitleSource
  Label: Source
  Group: Src
  Data: &lt;searchLink fieldCode=&quot;JN&quot; term=&quot;%22European+Radiology%22&quot;&gt;European Radiology&lt;/searchLink&gt;. Jan2001, Vol. 11 Issue 1, p18-27. 10p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: &lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Diuretics%22&quot;&gt;Diuretics&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Visual+perception%22&quot;&gt;Visual perception&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Urinary+organs%22&quot;&gt;Urinary organs&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Gastrointestinal+motility%22&quot;&gt;Gastrointestinal motility&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Muscle+contraction%22&quot;&gt;Muscle contraction&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Critical+care+medicine%22&quot;&gt;Critical care medicine&lt;/searchLink&gt;
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: The aim of this study was to investigate the utility of different gadolinium-enhanced T1-weighted gradient-echo techniques in excretory MR urography. In 74 urologic patients, excretory MR urography was performed using various T1-weighted gradient-echo (GRE) sequences after injection of gadolinium-DTPA and low-dose furosemide. The examinations included conventional GRE sequences and echo-planar imaging (GRE EPI), both obtained with 3D data sets and 2D projection images. Breath-hold acquisition was used primarily. In 20 of 74 examinations, we compared breath-hold imaging with respiratory gating. Breath-hold imaging was significantly superior to respiratory gating for the visualization of pelvicaliceal systems, but not for the ureters. Complete MR urograms were obtained within 14-20 s using 3D GRE EPI sequences and in 20-30 s with conventional 3D GRE sequences. Ghost artefacts caused by ureteral peristalsis often occurred with conventional 3D GRE imaging and were almost completely suppressed in EPI sequences (p &lt; 0.0001). Susceptibility effects were more pronounced on GRE EPI MR urograms and calculi measured 0.8-21.7% greater in diameter compared with conventional GRE sequences. Increased spatial resolution degraded the image quality only in GRE-EPI urograms. In projection MR urography, the entire pelvicaliceal system was imaged by acquisition of a fast single-slice sequence and the conventional 2D GRE technique provided superior morphological accuracy than 2D GRE EPI projection images (p &lt; 0.0003). Fast 3D GRE EPI sequences improve the clinical practicability of excretory MR urography especially in old or critically ill patients unable to suspend breathing for more than 20 s. Conventional GRE sequences are superior to EPI in high-resolution detail MR urograms and in projection imaging. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: &lt;i&gt;Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder&#39;s express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.&lt;/i&gt; (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=15654338
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1007/s003300000634
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 10
        StartPage: 18
    Subjects:
      – SubjectFull: Diuretics
        Type: general
      – SubjectFull: Visual perception
        Type: general
      – SubjectFull: Urinary organs
        Type: general
      – SubjectFull: Gastrointestinal motility
        Type: general
      – SubjectFull: Muscle contraction
        Type: general
      – SubjectFull: Critical care medicine
        Type: general
    Titles:
      – TitleFull: Diuretic-enhanced gadolinium excretory MR urography: comparison of conventional gradient-echo sequences and echo-planar imaging.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Nolte-Ernsting, C. A.
      – PersonEntity:
          Name:
            NameFull: Tacke, Josef
      – PersonEntity:
          Name:
            NameFull: Adam, Gerhard B.
      – PersonEntity:
          Name:
            NameFull: Haage, Patrick
      – PersonEntity:
          Name:
            NameFull: Jung, Peter
      – PersonEntity:
          Name:
            NameFull: Jakse, Gerhard
      – PersonEntity:
          Name:
            NameFull: Günther, Rolf W.
      – PersonEntity:
          Name:
            NameFull: Nolte-Ernsting, C C
      – PersonEntity:
          Name:
            NameFull: Tacke, J
      – PersonEntity:
          Name:
            NameFull: Adam, G B
      – PersonEntity:
          Name:
            NameFull: Haage, P
      – PersonEntity:
          Name:
            NameFull: Jung, P
      – PersonEntity:
          Name:
            NameFull: Jakse, G
      – PersonEntity:
          Name:
            NameFull: Günther, R W
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 01
              Text: Jan2001
              Type: published
              Y: 2001
          Identifiers:
            – Type: issn-print
              Value: 09387994
          Numbering:
            – Type: volume
              Value: 11
            – Type: issue
              Value: 1
          Titles:
            – TitleFull: European Radiology
              Type: main
ResultId 1