Bibliographic Details
| Title: |
Inferior mesenteric artery as outflow vessel in endoleaks after abdominal aortic stent-graft implantation: 36-month follow-up CT study. |
| Authors: |
Dorffner, Roland1 roland.dorffner@bbeisen.atuuml, Schoder, Maria2, Mostbeck, Gerhard1, Hölzenbein, Thomas3, Thurnher, Siegfried2, Lammer, Johannes2, Dorffner, R1 (AUTHOR), Schoder, M (AUTHOR), Mostbeck, G (AUTHOR), Hölzenbein, T (AUTHOR), Thurnher, S (AUTHOR), Lammer, J (AUTHOR) |
| Source: |
European Radiology. Nov2001, Vol. 11 Issue 11, p2252-2257. 6p. |
| Subjects: |
Mesenteric artery, Vascular diseases, Aortic aneurysms, Blood coagulation, Medical radiography, Diagnostic imaging |
| Abstract: |
The aim of this study was to determine the role of the inferior mesenteric artery (IMA) as an outflow vessel in endoleaks after abdominal aortic stent-graft implantation. Forty consecutive patients in whom abdominal aortic aneurysms (AAA) had been treated with stent-graft implantation were evaluated retrospectively. Spiral-CT examinations and angiographies up to 36 months after implantation were analyzed. In 29 (73%) of the 40 patients the IMA was perfused prior to implantation. In 5 (17%) of these 29 cases, the artery remained perfused after stent-graft insertion. In all 5 cases, endoleaks were detected; however, in none of these cases was the IMA the sole cause. In 3 of these 5 cases, angiography showed antegrade flow in the IMA. Implantation of extension stent grafts caused thrombosis of the aneurysmal sac and the IMA. There were no secondary endoleaks caused by the IMA at the 36-month follow-up examinations. The majority of IMAs which are patent prior to intervention occlude after successful stent-graft insertion. In cases with leaks and angiographically proven antegrade flow in the IMA, implantation of extension stent grafts is a therapeutic alternative to embolization. In this study, the IMA was not responsible for secondary endoleaks. [ABSTRACT FROM AUTHOR] |
|
Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) |
| Database: |
Engineering Source |