MR angiography vs CT angiography in the follow-up of nitinol stent grafts in endoluminally treated aortic aneurysms.
Saved in:
| Title: | MR angiography vs CT angiography in the follow-up of nitinol stent grafts in endoluminally treated aortic aneurysms. |
|---|---|
| Authors: | Cejna, Manfred1 manfred.cejna@univie.ac.at, Loewe, Christian1, Schoder, Maria1, Dirisamer, Albert1, Hölzenbein, Thomas2, Kretschmer, Georg2, Lammer, Johannes1, Thurnher, Siegfried1, Hölzenbein, Thomas (AUTHOR) |
| Source: | European Radiology. Oct2002, Vol. 12 Issue 10, p2443-2450. 8p. |
| Subjects: | Vascular diseases, Magnetic resonance, Angiography, Medical radiography, Surgical stents, Aneurysms |
| Abstract: | Our objective was to evaluate the accuracy of contrast-enhanced 3D MR angiography (MRA) in the follow-up of patients with endoluminally treated aortic aneurysms and correlate these findings with uni- or biphasic CT angiography (CTA). Forty MR angiograms in 32 patients with implanted aortic nitinol stent grafts were compared to CTA. Twenty-two MR examinations were correlated with arterial-phase CTA (uniphasic), and 18 MR examinations were correlated with biphasic CTA. Uniphasic CTA demonstrated three type-1/type-3 endoleaks and four reperfusion (type-2) endoleaks. In addition, MRA depicted two type-2 reperfusion endoleaks that were missed by CTA. Using biphasic CTA, two type-1/type-3 endoleaks and three reperfusion (type-2) endoleaks were detected; of those, delayed scanning detected three reperfusion (type-2) endoleaks missed during arterial-phase CTA. In addition to the findings by CTA, MRA depicted another type-2 reperfusion endoleak. Magnetic resonance angiography is at least as sensitive as uni- or biphasic CTA for detecting endoleaks and may consequently offer advantages in patients with contraindications to iodinated contrast agents. [ABSTRACT FROM AUTHOR] |
| Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
| FullText | Links: – Type: pdflink Text: Availability: 0 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 15662121 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: MR angiography vs CT angiography in the follow-up of nitinol stent grafts in endoluminally treated aortic aneurysms. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Cejna%2C+Manfred%22">Cejna, Manfred</searchLink><relatesTo>1</relatesTo><i> manfred.cejna@univie.ac.at</i><br /><searchLink fieldCode="AR" term="%22Loewe%2C+Christian%22">Loewe, Christian</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Schoder%2C+Maria%22">Schoder, Maria</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Dirisamer%2C+Albert%22">Dirisamer, Albert</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Hölzenbein%2C+Thomas%22">Hölzenbein, Thomas</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Kretschmer%2C+Georg%22">Kretschmer, Georg</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Lammer%2C+Johannes%22">Lammer, Johannes</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Thurnher%2C+Siegfried%22">Thurnher, Siegfried</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Hölzenbein%2C+Thomas%22">Hölzenbein, Thomas</searchLink> (AUTHOR) – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22European+Radiology%22">European Radiology</searchLink>. Oct2002, Vol. 12 Issue 10, p2443-2450. 8p. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22Vascular+diseases%22">Vascular diseases</searchLink><br /><searchLink fieldCode="DE" term="%22Magnetic+resonance%22">Magnetic resonance</searchLink><br /><searchLink fieldCode="DE" term="%22Angiography%22">Angiography</searchLink><br /><searchLink fieldCode="DE" term="%22Medical+radiography%22">Medical radiography</searchLink><br /><searchLink fieldCode="DE" term="%22Surgical+stents%22">Surgical stents</searchLink><br /><searchLink fieldCode="DE" term="%22Aneurysms%22">Aneurysms</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: Our objective was to evaluate the accuracy of contrast-enhanced 3D MR angiography (MRA) in the follow-up of patients with endoluminally treated aortic aneurysms and correlate these findings with uni- or biphasic CT angiography (CTA). Forty MR angiograms in 32 patients with implanted aortic nitinol stent grafts were compared to CTA. Twenty-two MR examinations were correlated with arterial-phase CTA (uniphasic), and 18 MR examinations were correlated with biphasic CTA. Uniphasic CTA demonstrated three type-1/type-3 endoleaks and four reperfusion (type-2) endoleaks. In addition, MRA depicted two type-2 reperfusion endoleaks that were missed by CTA. Using biphasic CTA, two type-1/type-3 endoleaks and three reperfusion (type-2) endoleaks were detected; of those, delayed scanning detected three reperfusion (type-2) endoleaks missed during arterial-phase CTA. In addition to the findings by CTA, MRA depicted another type-2 reperfusion endoleak. Magnetic resonance angiography is at least as sensitive as uni- or biphasic CTA for detecting endoleaks and may consequently offer advantages in patients with contraindications to iodinated contrast agents. [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=15662121 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1007/s00330-002-1429-8 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 8 StartPage: 2443 Subjects: – SubjectFull: Vascular diseases Type: general – SubjectFull: Magnetic resonance Type: general – SubjectFull: Angiography Type: general – SubjectFull: Medical radiography Type: general – SubjectFull: Surgical stents Type: general – SubjectFull: Aneurysms Type: general Titles: – TitleFull: MR angiography vs CT angiography in the follow-up of nitinol stent grafts in endoluminally treated aortic aneurysms. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Cejna, Manfred – PersonEntity: Name: NameFull: Loewe, Christian – PersonEntity: Name: NameFull: Schoder, Maria – PersonEntity: Name: NameFull: Dirisamer, Albert – PersonEntity: Name: NameFull: Hölzenbein, Thomas – PersonEntity: Name: NameFull: Kretschmer, Georg – PersonEntity: Name: NameFull: Lammer, Johannes – PersonEntity: Name: NameFull: Thurnher, Siegfried – PersonEntity: Name: NameFull: Hölzenbein, Thomas IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 10 Text: Oct2002 Type: published Y: 2002 Identifiers: – Type: issn-print Value: 09387994 Numbering: – Type: volume Value: 12 – Type: issue Value: 10 Titles: – TitleFull: European Radiology Type: main |
| ResultId | 1 |