The petromastoid canal on computed tomography.

Saved in:
Bibliographic Details
Title: The petromastoid canal on computed tomography.
Authors: Krombach, G.1 krombach@rad.rwth-aachen.de, Schmitz-Rode, T.1, Prescher, A.2, DiMartino, E.3, Weidner, J.1, G&uum;nther, R.W.1, Krombach, G A1 (AUTHOR), Günther, R W (AUTHOR)
Source: European Radiology. Nov2002, Vol. 12 Issue 11, p2770-2775. 6p.
Subjects: Tomography, Medical radiography, Anatomy, Medical imaging systems, Medical equipment, Preventive medicine
Abstract: The objective was to assess visibility and anatomy of the petromastoid canal in high-resolution CT. Computed tomography images of 188 patients were reviewed for delineation of the petromastoid canal. This bony canal connects the mastoid antrum with the cranial cavity and houses the subarcuate artery and vein. The diameter, obtained in the middle portion of the canal, was compared with the diameter of the vestibular and cochlear aqueduct in all patients, and absolute values measured in 20 cases. Collimation was 1 mm in 164 and 2 mm in 24 examinations. Additionally, temporal bone of a cadaver was imaged and microdissected. The petromastoid canal was identified bilaterally in all 164 scans that were obtained with a slice thickness of 1 mm. In 5 of the 24 patients imaged with a collimation of 2 mm, the canal was not visible, most probably due to partial-volume effects. The petromastoid canal had the same diameter as the cochlear aqueduct in 42/44 (right/left), exceeded it in 66/61 and was smaller in 75/78 cases. In comparison to the vestibular aqueduct it had an equal diameter in 38/41 (right/left), exceeded it in 63/61, and was rated as smaller in 82/81 temporal bones. Diameters for the canals were: petromastoid canal 0.51+/-0.04 mm; cochlear aqueduct 0.57+/-0.03; and vestibular aqueduct 0.63+/-0.06 mm. Microdissection of the specimen revealed the entire course of the canal and demonstrated a similar appearance of the structure as in the images. The petromastoid canal can easily be identified on high-resolution, thin-slice CT images. Knowledge of the anatomy of this bony canal prevents misinterpretation as pathological structure, such as fracture line, which might occur if this structure is not known. [ABSTRACT FROM AUTHOR]
Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Links:
  – Type: pdflink
Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 15662151
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: The petromastoid canal on computed tomography.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Krombach%2C+G%2E%22">Krombach, G.</searchLink><relatesTo>1</relatesTo><i> krombach@rad.rwth-aachen.de</i><br /><searchLink fieldCode="AR" term="%22Schmitz-Rode%2C+T%2E%22">Schmitz-Rode, T.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Prescher%2C+A%2E%22">Prescher, A.</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22DiMartino%2C+E%2E%22">DiMartino, E.</searchLink><relatesTo>3</relatesTo><br /><searchLink fieldCode="AR" term="%22Weidner%2C+J%2E%22">Weidner, J.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22G%26uum%3Bnther%2C+R%2EW%2E%22">G&uum;nther, R.W.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Krombach%2C+G+A%22">Krombach, G A</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Günther%2C+R+W%22">Günther, R W</searchLink> (AUTHOR)
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22European+Radiology%22">European Radiology</searchLink>. Nov2002, Vol. 12 Issue 11, p2770-2775. 6p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Tomography%22">Tomography</searchLink><br /><searchLink fieldCode="DE" term="%22Medical+radiography%22">Medical radiography</searchLink><br /><searchLink fieldCode="DE" term="%22Anatomy%22">Anatomy</searchLink><br /><searchLink fieldCode="DE" term="%22Medical+imaging+systems%22">Medical imaging systems</searchLink><br /><searchLink fieldCode="DE" term="%22Medical+equipment%22">Medical equipment</searchLink><br /><searchLink fieldCode="DE" term="%22Preventive+medicine%22">Preventive medicine</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: The objective was to assess visibility and anatomy of the petromastoid canal in high-resolution CT. Computed tomography images of 188 patients were reviewed for delineation of the petromastoid canal. This bony canal connects the mastoid antrum with the cranial cavity and houses the subarcuate artery and vein. The diameter, obtained in the middle portion of the canal, was compared with the diameter of the vestibular and cochlear aqueduct in all patients, and absolute values measured in 20 cases. Collimation was 1 mm in 164 and 2 mm in 24 examinations. Additionally, temporal bone of a cadaver was imaged and microdissected. The petromastoid canal was identified bilaterally in all 164 scans that were obtained with a slice thickness of 1 mm. In 5 of the 24 patients imaged with a collimation of 2 mm, the canal was not visible, most probably due to partial-volume effects. The petromastoid canal had the same diameter as the cochlear aqueduct in 42/44 (right/left), exceeded it in 66/61 and was smaller in 75/78 cases. In comparison to the vestibular aqueduct it had an equal diameter in 38/41 (right/left), exceeded it in 63/61, and was rated as smaller in 82/81 temporal bones. Diameters for the canals were: petromastoid canal 0.51+/-0.04 mm; cochlear aqueduct 0.57+/-0.03; and vestibular aqueduct 0.63+/-0.06 mm. Microdissection of the specimen revealed the entire course of the canal and demonstrated a similar appearance of the structure as in the images. The petromastoid canal can easily be identified on high-resolution, thin-slice CT images. Knowledge of the anatomy of this bony canal prevents misinterpretation as pathological structure, such as fracture line, which might occur if this structure is not known. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=15662151
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1007/s00330-002-1306-5
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 6
        StartPage: 2770
    Subjects:
      – SubjectFull: Tomography
        Type: general
      – SubjectFull: Medical radiography
        Type: general
      – SubjectFull: Anatomy
        Type: general
      – SubjectFull: Medical imaging systems
        Type: general
      – SubjectFull: Medical equipment
        Type: general
      – SubjectFull: Preventive medicine
        Type: general
    Titles:
      – TitleFull: The petromastoid canal on computed tomography.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Krombach, G.
      – PersonEntity:
          Name:
            NameFull: Schmitz-Rode, T.
      – PersonEntity:
          Name:
            NameFull: Prescher, A.
      – PersonEntity:
          Name:
            NameFull: DiMartino, E.
      – PersonEntity:
          Name:
            NameFull: Weidner, J.
      – PersonEntity:
          Name:
            NameFull: G&uum;nther, R.W.
      – PersonEntity:
          Name:
            NameFull: Krombach, G A
      – PersonEntity:
          Name:
            NameFull: Günther, R W
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 11
              Text: Nov2002
              Type: published
              Y: 2002
          Identifiers:
            – Type: issn-print
              Value: 09387994
          Numbering:
            – Type: volume
              Value: 12
            – Type: issue
              Value: 11
          Titles:
            – TitleFull: European Radiology
              Type: main
ResultId 1