Computational study for temperature distribution in ArF excimer laser corneal refractive surgeries using different beam delivery techniques.

Saved in:
Bibliographic Details
Title: Computational study for temperature distribution in ArF excimer laser corneal refractive surgeries using different beam delivery techniques.
Authors: Gokul, K. C.1 (AUTHOR) gokul.kc@ku.edu.np, Kandel, Himal2 (AUTHOR), Valiño, Luis3 (AUTHOR), Kaiti, Raju4 (AUTHOR), Roy, Prosun5 (AUTHOR), Sohail, Muhammad6 (AUTHOR), Gurung, Dil Bahadur1 (AUTHOR)
Source: Lasers in Medical Science. Apr2022, Vol. 37 Issue 3, p1709-1716. 8p.
Subjects: Excimer lasers, Temperature distribution, Laser surgery, Finite element method, Denaturation of proteins, Surgical complications, Cornea
Abstract: Refractive errors are the most common causes of vision impairment worldwide and laser refractive surgery is one of the most frequently performed ocular surgeries. Clinical studies have reported that approximately 10.5% of patients need an additional procedure after the surgery. The major complications of laser surgery are over/under correction and dry eye. An increase in temperature may be a cause for these complications. The purpose of this study was to estimate the increase in temperature during laser refractive surgery and its relationship with the complications observed for different surgical techniques. In this paper, a finite element model was applied to investigate the temperature distribution of the cornea when subjected to ArF excimer laser at a single spot using various beam delivery systems (broad beam, scanning slit, and flying spot). The Pennes bio-heat equation was used to predict the temperature values at different laser pulse energies and frequencies. The maximum temperature increase by ArF laser ( 500 Hz frequency and 0.5 J pulse energy) at a single spot was 33. 94 ∘ C , 15. 86 ∘ C , 12. 48 ∘ C for 6 diopter correction ( 65.4 μ m of ablation of corneal stroma) using broad beam, scanning slit, and flying spot beam delivery approaches respectively. The peak temperature due to a single pulse was estimated to be 234. 14 ∘ C . Although the peak temperature (sufficient energy to break intermolecular bonds) exists for a very short time ( 10 - 30 ns ) compared to the thermal relaxation time ( 2000 - 10 , 000 μ s ), there is some thermal energy exchange between corneal tissues during a laser refractive surgery. Heating may cause collagen denaturation, collagen shrinkage, and more evaporation and hence proposed to be a risk factor for over/under correction and dry eye. [ABSTRACT FROM AUTHOR]
Copyright of Lasers in Medical Science is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Full text is not displayed to guests.
FullText Links:
  – Type: pdflink
Text:
  Availability: 1
Header DbId: egs
DbLabel: Engineering Source
An: 156932200
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Computational study for temperature distribution in ArF excimer laser corneal refractive surgeries using different beam delivery techniques.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Gokul%2C+K%2E+C%2E%22">Gokul, K. C.</searchLink><relatesTo>1</relatesTo> (AUTHOR)<i> gokul.kc@ku.edu.np</i><br /><searchLink fieldCode="AR" term="%22Kandel%2C+Himal%22">Kandel, Himal</searchLink><relatesTo>2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Valiño%2C+Luis%22">Valiño, Luis</searchLink><relatesTo>3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Kaiti%2C+Raju%22">Kaiti, Raju</searchLink><relatesTo>4</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Roy%2C+Prosun%22">Roy, Prosun</searchLink><relatesTo>5</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Sohail%2C+Muhammad%22">Sohail, Muhammad</searchLink><relatesTo>6</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Gurung%2C+Dil+Bahadur%22">Gurung, Dil Bahadur</searchLink><relatesTo>1</relatesTo> (AUTHOR)
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Lasers+in+Medical+Science%22">Lasers in Medical Science</searchLink>. Apr2022, Vol. 37 Issue 3, p1709-1716. 8p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Excimer+lasers%22">Excimer lasers</searchLink><br /><searchLink fieldCode="DE" term="%22Temperature+distribution%22">Temperature distribution</searchLink><br /><searchLink fieldCode="DE" term="%22Laser+surgery%22">Laser surgery</searchLink><br /><searchLink fieldCode="DE" term="%22Finite+element+method%22">Finite element method</searchLink><br /><searchLink fieldCode="DE" term="%22Denaturation+of+proteins%22">Denaturation of proteins</searchLink><br /><searchLink fieldCode="DE" term="%22Surgical+complications%22">Surgical complications</searchLink><br /><searchLink fieldCode="DE" term="%22Cornea%22">Cornea</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Refractive errors are the most common causes of vision impairment worldwide and laser refractive surgery is one of the most frequently performed ocular surgeries. Clinical studies have reported that approximately 10.5% of patients need an additional procedure after the surgery. The major complications of laser surgery are over/under correction and dry eye. An increase in temperature may be a cause for these complications. The purpose of this study was to estimate the increase in temperature during laser refractive surgery and its relationship with the complications observed for different surgical techniques. In this paper, a finite element model was applied to investigate the temperature distribution of the cornea when subjected to ArF excimer laser at a single spot using various beam delivery systems (broad beam, scanning slit, and flying spot). The Pennes bio-heat equation was used to predict the temperature values at different laser pulse energies and frequencies. The maximum temperature increase by ArF laser ( 500 Hz frequency and 0.5 J pulse energy) at a single spot was 33. 94 ∘ C , 15. 86 ∘ C , 12. 48 ∘ C for 6 diopter correction ( 65.4 μ m of ablation of corneal stroma) using broad beam, scanning slit, and flying spot beam delivery approaches respectively. The peak temperature due to a single pulse was estimated to be 234. 14 ∘ C . Although the peak temperature (sufficient energy to break intermolecular bonds) exists for a very short time ( 10 - 30 ns ) compared to the thermal relaxation time ( 2000 - 10 , 000 μ s ), there is some thermal energy exchange between corneal tissues during a laser refractive surgery. Heating may cause collagen denaturation, collagen shrinkage, and more evaporation and hence proposed to be a risk factor for over/under correction and dry eye. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Lasers in Medical Science is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=156932200
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1007/s10103-021-03420-z
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 8
        StartPage: 1709
    Subjects:
      – SubjectFull: Excimer lasers
        Type: general
      – SubjectFull: Temperature distribution
        Type: general
      – SubjectFull: Laser surgery
        Type: general
      – SubjectFull: Finite element method
        Type: general
      – SubjectFull: Denaturation of proteins
        Type: general
      – SubjectFull: Surgical complications
        Type: general
      – SubjectFull: Cornea
        Type: general
    Titles:
      – TitleFull: Computational study for temperature distribution in ArF excimer laser corneal refractive surgeries using different beam delivery techniques.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Gokul, K. C.
      – PersonEntity:
          Name:
            NameFull: Kandel, Himal
      – PersonEntity:
          Name:
            NameFull: Valiño, Luis
      – PersonEntity:
          Name:
            NameFull: Kaiti, Raju
      – PersonEntity:
          Name:
            NameFull: Roy, Prosun
      – PersonEntity:
          Name:
            NameFull: Sohail, Muhammad
      – PersonEntity:
          Name:
            NameFull: Gurung, Dil Bahadur
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 04
              Text: Apr2022
              Type: published
              Y: 2022
          Identifiers:
            – Type: issn-print
              Value: 02688921
          Numbering:
            – Type: volume
              Value: 37
            – Type: issue
              Value: 3
          Titles:
            – TitleFull: Lasers in Medical Science
              Type: main
ResultId 1