Is the radiopacity of CAD/CAM aesthetic materials sufficient?

Saved in:
Bibliographic Details
Title: Is the radiopacity of CAD/CAM aesthetic materials sufficient?
Authors: Babaier, Rua S.1,2 (AUTHOR), Aldeeb, Modi S.2 (AUTHOR), Silikas, Nick1 (AUTHOR) nikolaos.silikas@manchester.ac.uk, Watts, David C.1,3 (AUTHOR) david.watts@manchester.ac.uk
Source: Dental Materials. Jun2022, Vol. 38 Issue 6, p1072-1081. 10p.
Subjects: Radiopacity, Dental materials, Digital images, Kruskal-Wallis Test, Aesthetics, Dental technology
Abstract: This study was designed to investigate CAD/CAM restorative blocks and other resin-based materials by (i) determining their chemical composition, (ii) comparing their radiopacity and (iii) correlating their radiopacity with specimen thickness. Disk specimens, of 1and 2 mm thickness (n = 3), were prepared from five CAD/CAM and six resin-based composites (RBCs). The CAD/CAM resin-composites included aesthetic types: CeraSmart (CS), Grandio Blocs (GB), Lava Ultimate (LU), plus a polymer infiltrated ceramic Vita Enamic (VE), and a feldspathic ceramic Vita Mark II (VM II). The six RBCs were for different clinical applications: direct filling, flowable, bulk fill, base and two luting cements. The specimens were radiographed alongside an aluminium step wedge and a tooth section. Digital images were analysed, and the radiopacity of each specimen was determined according to ISO 1311/2014. Statistical analyses of radiopacity, expressed as mm Al (n = 15), were carried out using the Kruskal-Wallis test followed by pairwise comparisons (α = 0.05). Radiopacities of CAD/CAM materials were, in ascending order, VE, VM II, CS, LU, and GB. At 1 mm thickness, the radiopacities of all CAD/CAM specimens were matching or slightly lower than enamel. At 2-mm thickness, the resin composite blocks were significantly more radiopaque than the ceramics VE and VM II (p < 0.0001). No statistically significant differences in radiopacity were detected between the 1-mm thick infiltrated ceramic, enamel, dentin and various resin composites except for filling and bulk fill types. The radiopacity of polymer-infiltrated ceramics was low despite the presence of radiopacifying elements and high filler content. Identifying thin restorations in standard radiographs is necessary with the development and expanded application of 'digital' dental materials in restorative treatment. This study confirmed the joint influence of composition and thickness on radiopacity. CAD/CAM restorative materials showed thickness-dependant radiopacity. But polymer-infiltrated ceramics were fairly radiolucent. There is a need to revisit radiopacity requirements for CAD/CAM restorative materials. [ABSTRACT FROM AUTHOR]
Copyright of Dental Materials is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 157076031
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Is the radiopacity of CAD/CAM aesthetic materials sufficient?
– Name: Author
  Label: Authors
  Group: Au
  Data: &lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Babaier%2C+Rua+S%2E%22&quot;&gt;Babaier, Rua S.&lt;/searchLink&gt;&lt;relatesTo&gt;1,2&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Aldeeb%2C+Modi+S%2E%22&quot;&gt;Aldeeb, Modi S.&lt;/searchLink&gt;&lt;relatesTo&gt;2&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Silikas%2C+Nick%22&quot;&gt;Silikas, Nick&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt; (AUTHOR)&lt;i&gt; nikolaos.silikas@manchester.ac.uk&lt;/i&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Watts%2C+David+C%2E%22&quot;&gt;Watts, David C.&lt;/searchLink&gt;&lt;relatesTo&gt;1,3&lt;/relatesTo&gt; (AUTHOR)&lt;i&gt; david.watts@manchester.ac.uk&lt;/i&gt;
– Name: TitleSource
  Label: Source
  Group: Src
  Data: &lt;searchLink fieldCode=&quot;JN&quot; term=&quot;%22Dental+Materials%22&quot;&gt;Dental Materials&lt;/searchLink&gt;. Jun2022, Vol. 38 Issue 6, p1072-1081. 10p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: &lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Radiopacity%22&quot;&gt;Radiopacity&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Dental+materials%22&quot;&gt;Dental materials&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Digital+images%22&quot;&gt;Digital images&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Kruskal-Wallis+Test%22&quot;&gt;Kruskal-Wallis Test&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Aesthetics%22&quot;&gt;Aesthetics&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Dental+technology%22&quot;&gt;Dental technology&lt;/searchLink&gt;
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: This study was designed to investigate CAD/CAM restorative blocks and other resin-based materials by (i) determining their chemical composition, (ii) comparing their radiopacity and (iii) correlating their radiopacity with specimen thickness. Disk specimens, of 1and 2 mm thickness (n = 3), were prepared from five CAD/CAM and six resin-based composites (RBCs). The CAD/CAM resin-composites included aesthetic types: CeraSmart (CS), Grandio Blocs (GB), Lava Ultimate (LU), plus a polymer infiltrated ceramic Vita Enamic (VE), and a feldspathic ceramic Vita Mark II (VM II). The six RBCs were for different clinical applications: direct filling, flowable, bulk fill, base and two luting cements. The specimens were radiographed alongside an aluminium step wedge and a tooth section. Digital images were analysed, and the radiopacity of each specimen was determined according to ISO 1311/2014. Statistical analyses of radiopacity, expressed as mm Al (n = 15), were carried out using the Kruskal-Wallis test followed by pairwise comparisons (α = 0.05). Radiopacities of CAD/CAM materials were, in ascending order, VE, VM II, CS, LU, and GB. At 1 mm thickness, the radiopacities of all CAD/CAM specimens were matching or slightly lower than enamel. At 2-mm thickness, the resin composite blocks were significantly more radiopaque than the ceramics VE and VM II (p &lt; 0.0001). No statistically significant differences in radiopacity were detected between the 1-mm thick infiltrated ceramic, enamel, dentin and various resin composites except for filling and bulk fill types. The radiopacity of polymer-infiltrated ceramics was low despite the presence of radiopacifying elements and high filler content. Identifying thin restorations in standard radiographs is necessary with the development and expanded application of &#39;digital&#39; dental materials in restorative treatment. This study confirmed the joint influence of composition and thickness on radiopacity. CAD/CAM restorative materials showed thickness-dependant radiopacity. But polymer-infiltrated ceramics were fairly radiolucent. There is a need to revisit radiopacity requirements for CAD/CAM restorative materials. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: &lt;i&gt;Copyright of Dental Materials is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder&#39;s express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.&lt;/i&gt; (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=157076031
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1016/j.dental.2022.04.025
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 10
        StartPage: 1072
    Subjects:
      – SubjectFull: Radiopacity
        Type: general
      – SubjectFull: Dental materials
        Type: general
      – SubjectFull: Digital images
        Type: general
      – SubjectFull: Kruskal-Wallis Test
        Type: general
      – SubjectFull: Aesthetics
        Type: general
      – SubjectFull: Dental technology
        Type: general
    Titles:
      – TitleFull: Is the radiopacity of CAD/CAM aesthetic materials sufficient?
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Babaier, Rua S.
      – PersonEntity:
          Name:
            NameFull: Aldeeb, Modi S.
      – PersonEntity:
          Name:
            NameFull: Silikas, Nick
      – PersonEntity:
          Name:
            NameFull: Watts, David C.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 06
              Text: Jun2022
              Type: published
              Y: 2022
          Identifiers:
            – Type: issn-print
              Value: 01095641
          Numbering:
            – Type: volume
              Value: 38
            – Type: issue
              Value: 6
          Titles:
            – TitleFull: Dental Materials
              Type: main
ResultId 1