Automated artifact detection in abbreviated dynamic contrast-enhanced (DCE) MRI-derived maximum intensity projections (MIPs) of the breast.

Saved in:
Bibliographic Details
Title: Automated artifact detection in abbreviated dynamic contrast-enhanced (DCE) MRI-derived maximum intensity projections (MIPs) of the breast.
Authors: Kapsner, Lorenz A.1,2 (AUTHOR) lorenz.kapsner@uk-erlangen.de, Ohlmeyer, Sabine1 (AUTHOR), Folle, Lukas3 (AUTHOR), Laun, Frederik B.1 (AUTHOR), Nagel, Armin M.1 (AUTHOR), Liebert, Andrzej1 (AUTHOR), Schreiter, Hannes1 (AUTHOR), Beckmann, Matthias W.4 (AUTHOR), Uder, Michael1 (AUTHOR), Wenkel, Evelyn1 (AUTHOR), Bickelhaupt, Sebastian1,5 (AUTHOR)
Source: European Radiology. Sep2022, Vol. 32 Issue 9, p5997-6007. 11p. 1 Color Photograph, 1 Black and White Photograph, 4 Charts, 2 Graphs.
Abstract: Objectives: To automatically detect MRI artifacts on dynamic contrast-enhanced (DCE) maximum intensity projections (MIPs) of the breast using deep learning. Methods: Women who underwent clinically indicated breast MRI between October 2015 and December 2019 were included in this IRB-approved retrospective study. We employed two convolutional neural network architectures (ResNet and DenseNet) to detect the presence of artifacts on DCE MIPs of the left and right breasts. Networks were trained on images acquired up to and including the year 2018 using a 5-fold cross-validation (CV). Ensemble classifiers were built with the resulting CV models and applied to an independent holdout test dataset, which was formed by images acquired in 2019. Results: Our study sample contained 2265 examinations from 1794 patients (median age at first acquisition: 50 years [IQR: 17 years]), corresponding to 1827 examinations of 1378 individuals in the training dataset and 438 examinations of 416 individuals in the holdout test dataset with a prevalence of image-level artifacts of 53% (1951/3654 images) and 43% (381/876 images), respectively. On the holdout test dataset, the ResNet and DenseNet ensembles demonstrated an area under the ROC curve of 0.92 and 0.94, respectively. Conclusion: Neural networks are able to reliably detect artifacts that may impede the diagnostic assessment of MIPs derived from DCE subtraction series in breast MRI. Future studies need to further explore the potential of such neural networks to complement quality assurance and improve the application of DCE MIPs in a clinical setting, such as abbreviated protocols. Key Points: • Deep learning classifiers are able to reliably detect MRI artifacts in dynamic contrast-enhanced protocol-derived maximum intensity projections of the breast. • Automated quality assurance of maximum intensity projections of the breast may be of special relevance for abbreviated breast MRI, e.g., in high-throughput settings, such as cancer screening programs. [ABSTRACT FROM AUTHOR]
Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Full text is not displayed to guests.
FullText Links:
  – Type: pdflink
Text:
  Availability: 1
Header DbId: egs
DbLabel: Engineering Source
An: 158546980
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Automated artifact detection in abbreviated dynamic contrast-enhanced (DCE) MRI-derived maximum intensity projections (MIPs) of the breast.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Kapsner%2C+Lorenz+A%2E%22">Kapsner, Lorenz A.</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)<i> lorenz.kapsner@uk-erlangen.de</i><br /><searchLink fieldCode="AR" term="%22Ohlmeyer%2C+Sabine%22">Ohlmeyer, Sabine</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Folle%2C+Lukas%22">Folle, Lukas</searchLink><relatesTo>3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Laun%2C+Frederik+B%2E%22">Laun, Frederik B.</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Nagel%2C+Armin+M%2E%22">Nagel, Armin M.</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Liebert%2C+Andrzej%22">Liebert, Andrzej</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Schreiter%2C+Hannes%22">Schreiter, Hannes</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Beckmann%2C+Matthias+W%2E%22">Beckmann, Matthias W.</searchLink><relatesTo>4</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Uder%2C+Michael%22">Uder, Michael</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Wenkel%2C+Evelyn%22">Wenkel, Evelyn</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Bickelhaupt%2C+Sebastian%22">Bickelhaupt, Sebastian</searchLink><relatesTo>1,5</relatesTo> (AUTHOR)
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22European+Radiology%22">European Radiology</searchLink>. Sep2022, Vol. 32 Issue 9, p5997-6007. 11p. 1 Color Photograph, 1 Black and White Photograph, 4 Charts, 2 Graphs.
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Objectives: To automatically detect MRI artifacts on dynamic contrast-enhanced (DCE) maximum intensity projections (MIPs) of the breast using deep learning. Methods: Women who underwent clinically indicated breast MRI between October 2015 and December 2019 were included in this IRB-approved retrospective study. We employed two convolutional neural network architectures (ResNet and DenseNet) to detect the presence of artifacts on DCE MIPs of the left and right breasts. Networks were trained on images acquired up to and including the year 2018 using a 5-fold cross-validation (CV). Ensemble classifiers were built with the resulting CV models and applied to an independent holdout test dataset, which was formed by images acquired in 2019. Results: Our study sample contained 2265 examinations from 1794 patients (median age at first acquisition: 50 years [IQR: 17 years]), corresponding to 1827 examinations of 1378 individuals in the training dataset and 438 examinations of 416 individuals in the holdout test dataset with a prevalence of image-level artifacts of 53% (1951/3654 images) and 43% (381/876 images), respectively. On the holdout test dataset, the ResNet and DenseNet ensembles demonstrated an area under the ROC curve of 0.92 and 0.94, respectively. Conclusion: Neural networks are able to reliably detect artifacts that may impede the diagnostic assessment of MIPs derived from DCE subtraction series in breast MRI. Future studies need to further explore the potential of such neural networks to complement quality assurance and improve the application of DCE MIPs in a clinical setting, such as abbreviated protocols. Key Points: • Deep learning classifiers are able to reliably detect MRI artifacts in dynamic contrast-enhanced protocol-derived maximum intensity projections of the breast. • Automated quality assurance of maximum intensity projections of the breast may be of special relevance for abbreviated breast MRI, e.g., in high-throughput settings, such as cancer screening programs. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=158546980
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1007/s00330-022-08626-5
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 11
        StartPage: 5997
    Titles:
      – TitleFull: Automated artifact detection in abbreviated dynamic contrast-enhanced (DCE) MRI-derived maximum intensity projections (MIPs) of the breast.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Kapsner, Lorenz A.
      – PersonEntity:
          Name:
            NameFull: Ohlmeyer, Sabine
      – PersonEntity:
          Name:
            NameFull: Folle, Lukas
      – PersonEntity:
          Name:
            NameFull: Laun, Frederik B.
      – PersonEntity:
          Name:
            NameFull: Nagel, Armin M.
      – PersonEntity:
          Name:
            NameFull: Liebert, Andrzej
      – PersonEntity:
          Name:
            NameFull: Schreiter, Hannes
      – PersonEntity:
          Name:
            NameFull: Beckmann, Matthias W.
      – PersonEntity:
          Name:
            NameFull: Uder, Michael
      – PersonEntity:
          Name:
            NameFull: Wenkel, Evelyn
      – PersonEntity:
          Name:
            NameFull: Bickelhaupt, Sebastian
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 09
              Text: Sep2022
              Type: published
              Y: 2022
          Identifiers:
            – Type: issn-print
              Value: 09387994
          Numbering:
            – Type: volume
              Value: 32
            – Type: issue
              Value: 9
          Titles:
            – TitleFull: European Radiology
              Type: main
ResultId 1