Fourier‐based decomposition for simultaneous 2‐voxel MRS acquisition with 2SPECIAL.

Saved in:
Bibliographic Details
Title: Fourier‐based decomposition for simultaneous 2‐voxel MRS acquisition with 2SPECIAL.
Authors: Riemann, Layla Tabea1 (AUTHOR) layla.riemann@ptb.de, Aigner, Christoph Stefan1 (AUTHOR), Mekle, Ralf2 (AUTHOR), Speck, Oliver3,4 (AUTHOR), Rose, Georg4,5 (AUTHOR), Ittermann, Bernd1 (AUTHOR), Schmitter, Sebastian1,6,7 (AUTHOR), Fillmer, Ariane1 (AUTHOR)
Source: Magnetic Resonance in Medicine. Nov2022, Vol. 88 Issue 5, p1978-1993. 16p.
Subjects: Time measurements, Spectrometry
Abstract: Purpose: To simultaneously acquire spectroscopic signals from two MRS voxels using a multi‐banded 2 spin‐echo, full‐intensity acquired localized (2SPECIAL) sequence, and to decompose the signal to their respective regions by a novel voxel‐GRAPPA (vGRAPPA) decomposition approach for in vivo brain applications at 7 T. Methods: A wideband, uniform rate, smooth truncation (WURST) multi‐banded pulse was incorporated into SPECIAL to implement 2SPECIAL for simultaneous multi‐voxel spectroscopy (sMVS). To decompose the acquired data, the voxel‐GRAPPA decomposition algorithm is introduced, and its performance is compared to the SENSE‐based decomposition. Furthermore, the limitations of two‐voxel excitation concerning the multi‐banded adiabatic inversion pulse, as well as of the combined B0 shim and B1+ adjustments, are evaluated. Results: It was successfully shown that the 2SPECIAL sequence enables sMVS without a significant loss in SNR while reducing the total scan time by 21.6% compared to two consecutive acquisitions. The proposed voxel‐GRAPPA algorithm properly reassigns the signal components to their respective origin region and shows no significant differences to the well‐established SENSE‐based algorithm in terms of leakage (both <10%) or Cramér‐Rao lower bounds (CRLB) for in vivo applications, while not requiring the acquisition of additional sensitivity maps and thus decreasing motion sensitivity. Conclusion: The use of 2SPECIAL in combination with the novel voxel‐GRAPPA decomposition technique allows a substantial reduction of measurement time compared to the consecutive acquisition of two single voxels without a significant decrease in spectral quality or metabolite quantification accuracy and thus provides a new option for multiple‐voxel applications. [ABSTRACT FROM AUTHOR]
Copyright of Magnetic Resonance in Medicine is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Full text is not displayed to guests.
FullText Links:
  – Type: pdflink
Text:
  Availability: 1
Header DbId: egs
DbLabel: Engineering Source
An: 158696002
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Fourier‐based decomposition for simultaneous 2‐voxel MRS acquisition with 2SPECIAL.
– Name: Author
  Label: Authors
  Group: Au
  Data: &lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Riemann%2C+Layla+Tabea%22&quot;&gt;Riemann, Layla Tabea&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt; (AUTHOR)&lt;i&gt; layla.riemann@ptb.de&lt;/i&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Aigner%2C+Christoph+Stefan%22&quot;&gt;Aigner, Christoph Stefan&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Mekle%2C+Ralf%22&quot;&gt;Mekle, Ralf&lt;/searchLink&gt;&lt;relatesTo&gt;2&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Speck%2C+Oliver%22&quot;&gt;Speck, Oliver&lt;/searchLink&gt;&lt;relatesTo&gt;3,4&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Rose%2C+Georg%22&quot;&gt;Rose, Georg&lt;/searchLink&gt;&lt;relatesTo&gt;4,5&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Ittermann%2C+Bernd%22&quot;&gt;Ittermann, Bernd&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Schmitter%2C+Sebastian%22&quot;&gt;Schmitter, Sebastian&lt;/searchLink&gt;&lt;relatesTo&gt;1,6,7&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Fillmer%2C+Ariane%22&quot;&gt;Fillmer, Ariane&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt; (AUTHOR)
– Name: TitleSource
  Label: Source
  Group: Src
  Data: &lt;searchLink fieldCode=&quot;JN&quot; term=&quot;%22Magnetic+Resonance+in+Medicine%22&quot;&gt;Magnetic Resonance in Medicine&lt;/searchLink&gt;. Nov2022, Vol. 88 Issue 5, p1978-1993. 16p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: &lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Time+measurements%22&quot;&gt;Time measurements&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Spectrometry%22&quot;&gt;Spectrometry&lt;/searchLink&gt;
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Purpose: To simultaneously acquire spectroscopic signals from two MRS voxels using a multi‐banded 2 spin‐echo, full‐intensity acquired localized (2SPECIAL) sequence, and to decompose the signal to their respective regions by a novel voxel‐GRAPPA (vGRAPPA) decomposition approach for in vivo brain applications at 7 T. Methods: A wideband, uniform rate, smooth truncation (WURST) multi‐banded pulse was incorporated into SPECIAL to implement 2SPECIAL for simultaneous multi‐voxel spectroscopy (sMVS). To decompose the acquired data, the voxel‐GRAPPA decomposition algorithm is introduced, and its performance is compared to the SENSE‐based decomposition. Furthermore, the limitations of two‐voxel excitation concerning the multi‐banded adiabatic inversion pulse, as well as of the combined B0 shim and B1+ adjustments, are evaluated. Results: It was successfully shown that the 2SPECIAL sequence enables sMVS without a significant loss in SNR while reducing the total scan time by 21.6% compared to two consecutive acquisitions. The proposed voxel‐GRAPPA algorithm properly reassigns the signal components to their respective origin region and shows no significant differences to the well‐established SENSE‐based algorithm in terms of leakage (both &lt;10%) or Cram&#233;r‐Rao lower bounds (CRLB) for in vivo applications, while not requiring the acquisition of additional sensitivity maps and thus decreasing motion sensitivity. Conclusion: The use of 2SPECIAL in combination with the novel voxel‐GRAPPA decomposition technique allows a substantial reduction of measurement time compared to the consecutive acquisition of two single voxels without a significant decrease in spectral quality or metabolite quantification accuracy and thus provides a new option for multiple‐voxel applications. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: &lt;i&gt;Copyright of Magnetic Resonance in Medicine is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder&#39;s express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.&lt;/i&gt; (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=158696002
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1002/mrm.29369
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 16
        StartPage: 1978
    Subjects:
      – SubjectFull: Time measurements
        Type: general
      – SubjectFull: Spectrometry
        Type: general
    Titles:
      – TitleFull: Fourier‐based decomposition for simultaneous 2‐voxel MRS acquisition with 2SPECIAL.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Riemann, Layla Tabea
      – PersonEntity:
          Name:
            NameFull: Aigner, Christoph Stefan
      – PersonEntity:
          Name:
            NameFull: Mekle, Ralf
      – PersonEntity:
          Name:
            NameFull: Speck, Oliver
      – PersonEntity:
          Name:
            NameFull: Rose, Georg
      – PersonEntity:
          Name:
            NameFull: Ittermann, Bernd
      – PersonEntity:
          Name:
            NameFull: Schmitter, Sebastian
      – PersonEntity:
          Name:
            NameFull: Fillmer, Ariane
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 11
              Text: Nov2022
              Type: published
              Y: 2022
          Identifiers:
            – Type: issn-print
              Value: 07403194
          Numbering:
            – Type: volume
              Value: 88
            – Type: issue
              Value: 5
          Titles:
            – TitleFull: Magnetic Resonance in Medicine
              Type: main
ResultId 1