Developing a transwell millifluidic device for studying blood–brain barrier endothelium.
Saved in:
| Title: | Developing a transwell millifluidic device for studying blood–brain barrier endothelium. |
|---|---|
| Authors: | Harding, Ian C.1 (AUTHOR), O'Hare, Nicholas R.2 (AUTHOR), Vigliotti, Mark2 (AUTHOR), Caraballo, Alex2 (AUTHOR), Lee, Claire I.1 (AUTHOR), Millican, Karina1 (AUTHOR), Herman, Ira M.3,4 (AUTHOR), Ebong, Eno E.1,2,5 (AUTHOR) e.ebong@northeastern.edu |
| Source: | Lab on a Chip. 12/7/2022, Vol. 22 Issue 23, p4603-4620. 18p. |
| Subjects: | Pericytes, Blood-brain barrier, Endothelium, Shearing force, Microfluidic devices, Endothelial cells |
| Abstract: | Blood–brain barrier (BBB) endothelial cell (EC) function depends on flow conditions and on supportive cells, like pericytes and astrocytes, which have been shown to be both beneficial and detrimental for brain EC function. Most studies investigating BBB EC function lack physiological relevance, using sub-physiological shear stress magnitudes and/or omitting pericytes and astrocytes. In this study, we developed a millifluidic device compatible with standard transwell inserts to investigate BBB function. In contrast to standard polydimethylsiloxane (PDMS) microfluidic devices, this model allows for easy, reproducible shear stress exposure without common limitations of PDMS devices such as inadequate nutrient diffusion and air bubble formation. In no-flow conditions, we first used the device to examine the impact of primary human pericytes and astrocytes on human brain microvascular EC (HBMEC) barrier integrity. Astrocytes, pericytes, and a 1-to-1 ratio of both cell types increased HBMEC barrier integrity via reduced 3 and 40 kDa fluorescent dextran permeability and increased claudin-5 expression. There were differing levels of low 3 kDa permeability in HBMEC–pericyte, HBMEC–astrocyte, and HBMEC–astrocyte–pericyte co-cultures, while levels of low 40 kDa permeability were consistent across co-cultures. The 3 kDa findings suggest that pericytes provide more barrier support to the BBB model compared to astrocytes, although both supportive cell types are permeability reducers. Incorporation of 24-hour 12 dynes per cm2 flow significantly reduced dextran permeability in HBMEC monolayers, but not in the tri-culture model. These results indicate that tri-culture may exert more pronounced impact on overall BBB permeability than flow exposure. In both cases, monolayer and tri-culture, flow exposure interestingly reduced HBMEC expression of both claudin-5 and occludin. ZO-1 expression, and localization at cell–cell junctions increased in the tri-culture but exhibited no apparent change in the HBMEC monolayer. Under flow conditions, we also observed HBMEC alignment in the tri-culture but not in HBMEC monolayers, indicating supportive cells and flow are both essential to observe brain EC alignment in vitro. Collectively, these results support the necessity of physiologically relevant, multicellular BBB models when investigating BBB EC function. Consideration of the roles of shear stress and supportive cells within the BBB is critical for elucidating the physiology of the neurovascular unit. [ABSTRACT FROM AUTHOR] |
| Copyright of Lab on a Chip is the property of Royal Society of Chemistry and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
| FullText | Text: Availability: 0 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 160351885 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Developing a transwell millifluidic device for studying blood–brain barrier endothelium. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Harding%2C+Ian+C%2E%22">Harding, Ian C.</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22O'Hare%2C+Nicholas+R%2E%22">O'Hare, Nicholas R.</searchLink><relatesTo>2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Vigliotti%2C+Mark%22">Vigliotti, Mark</searchLink><relatesTo>2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Caraballo%2C+Alex%22">Caraballo, Alex</searchLink><relatesTo>2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Lee%2C+Claire+I%2E%22">Lee, Claire I.</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Millican%2C+Karina%22">Millican, Karina</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Herman%2C+Ira+M%2E%22">Herman, Ira M.</searchLink><relatesTo>3,4</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Ebong%2C+Eno+E%2E%22">Ebong, Eno E.</searchLink><relatesTo>1,2,5</relatesTo> (AUTHOR)<i> e.ebong@northeastern.edu</i> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Lab+on+a+Chip%22">Lab on a Chip</searchLink>. 12/7/2022, Vol. 22 Issue 23, p4603-4620. 18p. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22Pericytes%22">Pericytes</searchLink><br /><searchLink fieldCode="DE" term="%22Blood-brain+barrier%22">Blood-brain barrier</searchLink><br /><searchLink fieldCode="DE" term="%22Endothelium%22">Endothelium</searchLink><br /><searchLink fieldCode="DE" term="%22Shearing+force%22">Shearing force</searchLink><br /><searchLink fieldCode="DE" term="%22Microfluidic+devices%22">Microfluidic devices</searchLink><br /><searchLink fieldCode="DE" term="%22Endothelial+cells%22">Endothelial cells</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: Blood–brain barrier (BBB) endothelial cell (EC) function depends on flow conditions and on supportive cells, like pericytes and astrocytes, which have been shown to be both beneficial and detrimental for brain EC function. Most studies investigating BBB EC function lack physiological relevance, using sub-physiological shear stress magnitudes and/or omitting pericytes and astrocytes. In this study, we developed a millifluidic device compatible with standard transwell inserts to investigate BBB function. In contrast to standard polydimethylsiloxane (PDMS) microfluidic devices, this model allows for easy, reproducible shear stress exposure without common limitations of PDMS devices such as inadequate nutrient diffusion and air bubble formation. In no-flow conditions, we first used the device to examine the impact of primary human pericytes and astrocytes on human brain microvascular EC (HBMEC) barrier integrity. Astrocytes, pericytes, and a 1-to-1 ratio of both cell types increased HBMEC barrier integrity via reduced 3 and 40 kDa fluorescent dextran permeability and increased claudin-5 expression. There were differing levels of low 3 kDa permeability in HBMEC–pericyte, HBMEC–astrocyte, and HBMEC–astrocyte–pericyte co-cultures, while levels of low 40 kDa permeability were consistent across co-cultures. The 3 kDa findings suggest that pericytes provide more barrier support to the BBB model compared to astrocytes, although both supportive cell types are permeability reducers. Incorporation of 24-hour 12 dynes per cm2 flow significantly reduced dextran permeability in HBMEC monolayers, but not in the tri-culture model. These results indicate that tri-culture may exert more pronounced impact on overall BBB permeability than flow exposure. In both cases, monolayer and tri-culture, flow exposure interestingly reduced HBMEC expression of both claudin-5 and occludin. ZO-1 expression, and localization at cell–cell junctions increased in the tri-culture but exhibited no apparent change in the HBMEC monolayer. Under flow conditions, we also observed HBMEC alignment in the tri-culture but not in HBMEC monolayers, indicating supportive cells and flow are both essential to observe brain EC alignment in vitro. Collectively, these results support the necessity of physiologically relevant, multicellular BBB models when investigating BBB EC function. Consideration of the roles of shear stress and supportive cells within the BBB is critical for elucidating the physiology of the neurovascular unit. [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of Lab on a Chip is the property of Royal Society of Chemistry and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=160351885 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1039/d2lc00657j Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 18 StartPage: 4603 Subjects: – SubjectFull: Pericytes Type: general – SubjectFull: Blood-brain barrier Type: general – SubjectFull: Endothelium Type: general – SubjectFull: Shearing force Type: general – SubjectFull: Microfluidic devices Type: general – SubjectFull: Endothelial cells Type: general Titles: – TitleFull: Developing a transwell millifluidic device for studying blood–brain barrier endothelium. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Harding, Ian C. – PersonEntity: Name: NameFull: O'Hare, Nicholas R. – PersonEntity: Name: NameFull: Vigliotti, Mark – PersonEntity: Name: NameFull: Caraballo, Alex – PersonEntity: Name: NameFull: Lee, Claire I. – PersonEntity: Name: NameFull: Millican, Karina – PersonEntity: Name: NameFull: Herman, Ira M. – PersonEntity: Name: NameFull: Ebong, Eno E. IsPartOfRelationships: – BibEntity: Dates: – D: 07 M: 12 Text: 12/7/2022 Type: published Y: 2022 Identifiers: – Type: issn-print Value: 14730197 Numbering: – Type: volume Value: 22 – Type: issue Value: 23 Titles: – TitleFull: Lab on a Chip Type: main |
| ResultId | 1 |