Comparison of PMT‐based TF64 and SiPM‐based Vereos PET/CT systems for 90Y imaging and dosimetry optimization: A quantitative study.
Saved in:
| Title: | Comparison of PMT‐based TF64 and SiPM‐based Vereos PET/CT systems for 90Y imaging and dosimetry optimization: A quantitative study. |
|---|---|
| Authors: | Trotta, Nicola1 (AUTHOR) nicola.trotta@erasme.ulb.ac.be, Collette, Benoît1 (AUTHOR), Mathey, Céline1 (AUTHOR), Vierasu, Irina1 (AUTHOR), Bucalau, Ana‐Maria2 (AUTHOR), Verset, Gontran2 (AUTHOR), Moreno‐Reyes, Rodrigo1 (AUTHOR), Goldman, Serge1 (AUTHOR) |
| Source: | Medical Physics. Dec2022, Vol. 49 Issue 12, p7567-7582. 16p. |
| Subjects: | Imaging phantoms, Photomultipliers, Imaging systems, Radiation dosimetry, Positron emission tomography, Computed tomography, Quantitative research |
| Abstract: | Background: Selective internal radiotherapy based on transarterial radioembolization (TARE) with yttrium‐90 (90Y) microspheres is an established treatment for primary or metastatic liver disease. Purpose: The objective of this work is to optimize the dosimetry of patients treated with 90Y TARE, using positron emission tomography (PET) images. Methods: The NEMA 2012 PET phantom was filled with nearly 3.9 GBq of 90Y activity and acquired at days 0, 3, 5, 7, and 9 on a classic time‐of‐flight PET/computed tomography (CT) scanner (Philips TF64) and on a silicon photomultiplier (SiPM)‐based PET/CT scanner (Philips Vereos). Acquisitions were carried on following the guidelines proposed in a previously published multicentric trial and images were reconstructed by varying and combining the available parameters. Comparisons were performed to identify the best set(s) of parameters leading to the most accurate 90Y‐PET image(s), in terms of activity distribution. Then, for both scanners, the best images were analyzed with Simplicit90Y, a personalized dosimetry software using multicompartmental Medical Internal Radiation Dose model. The comparison between measured and true doses allowed to identify the image granting the most consistent dose estimations and, therefore, to designate the set of parameters to be applied on patients' data for the reconstruction of optimized clinical images. Posttreatment dosimetry of four patients was then realized with Simplicit90Y using optimized imaging datasets. Results: Based on activity distribution comparisons and dose estimations over phantom and patients data, the SiPM‐based PET/CT system appeared more suitable than the photomultiplier tube‐based TF64 for 90Y‐PET imaging. With the SiPM‐based PET/CT system, reconstructed images with a 2‐mm voxel size combined with the application of the point spread function correction led to the most accurate results for quantitative 90Y measures. Conclusions: For the SiPM‐based PET/CT scanner, an optimized set of reconstruction parameters has been identified and applied on patients' data in order to generate the most accurate image to be used for an improved personalized 90Y‐PET dosimetry, ensuring a reliable evaluation of the delivered doses. [ABSTRACT FROM AUTHOR] |
| Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
|
Full text is not displayed to guests.
Login for full access.
|
|
| FullText | Links: – Type: pdflink Text: Availability: 1 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 160990841 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Comparison of PMT‐based TF64 and SiPM‐based Vereos PET/CT systems for <superscript>90</superscript>Y imaging and dosimetry optimization: A quantitative study. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Trotta%2C+Nicola%22">Trotta, Nicola</searchLink><relatesTo>1</relatesTo> (AUTHOR)<i> nicola.trotta@erasme.ulb.ac.be</i><br /><searchLink fieldCode="AR" term="%22Collette%2C+Benoît%22">Collette, Benoît</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Mathey%2C+Céline%22">Mathey, Céline</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Vierasu%2C+Irina%22">Vierasu, Irina</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Bucalau%2C+Ana‐Maria%22">Bucalau, Ana‐Maria</searchLink><relatesTo>2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Verset%2C+Gontran%22">Verset, Gontran</searchLink><relatesTo>2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Moreno‐Reyes%2C+Rodrigo%22">Moreno‐Reyes, Rodrigo</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Goldman%2C+Serge%22">Goldman, Serge</searchLink><relatesTo>1</relatesTo> (AUTHOR) – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Medical+Physics%22">Medical Physics</searchLink>. Dec2022, Vol. 49 Issue 12, p7567-7582. 16p. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22Imaging+phantoms%22">Imaging phantoms</searchLink><br /><searchLink fieldCode="DE" term="%22Photomultipliers%22">Photomultipliers</searchLink><br /><searchLink fieldCode="DE" term="%22Imaging+systems%22">Imaging systems</searchLink><br /><searchLink fieldCode="DE" term="%22Radiation+dosimetry%22">Radiation dosimetry</searchLink><br /><searchLink fieldCode="DE" term="%22Positron+emission+tomography%22">Positron emission tomography</searchLink><br /><searchLink fieldCode="DE" term="%22Computed+tomography%22">Computed tomography</searchLink><br /><searchLink fieldCode="DE" term="%22Quantitative+research%22">Quantitative research</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: Background: Selective internal radiotherapy based on transarterial radioembolization (TARE) with yttrium‐90 (90Y) microspheres is an established treatment for primary or metastatic liver disease. Purpose: The objective of this work is to optimize the dosimetry of patients treated with 90Y TARE, using positron emission tomography (PET) images. Methods: The NEMA 2012 PET phantom was filled with nearly 3.9 GBq of 90Y activity and acquired at days 0, 3, 5, 7, and 9 on a classic time‐of‐flight PET/computed tomography (CT) scanner (Philips TF64) and on a silicon photomultiplier (SiPM)‐based PET/CT scanner (Philips Vereos). Acquisitions were carried on following the guidelines proposed in a previously published multicentric trial and images were reconstructed by varying and combining the available parameters. Comparisons were performed to identify the best set(s) of parameters leading to the most accurate 90Y‐PET image(s), in terms of activity distribution. Then, for both scanners, the best images were analyzed with Simplicit90Y, a personalized dosimetry software using multicompartmental Medical Internal Radiation Dose model. The comparison between measured and true doses allowed to identify the image granting the most consistent dose estimations and, therefore, to designate the set of parameters to be applied on patients' data for the reconstruction of optimized clinical images. Posttreatment dosimetry of four patients was then realized with Simplicit90Y using optimized imaging datasets. Results: Based on activity distribution comparisons and dose estimations over phantom and patients data, the SiPM‐based PET/CT system appeared more suitable than the photomultiplier tube‐based TF64 for 90Y‐PET imaging. With the SiPM‐based PET/CT system, reconstructed images with a 2‐mm voxel size combined with the application of the point spread function correction led to the most accurate results for quantitative 90Y measures. Conclusions: For the SiPM‐based PET/CT scanner, an optimized set of reconstruction parameters has been identified and applied on patients' data in order to generate the most accurate image to be used for an improved personalized 90Y‐PET dosimetry, ensuring a reliable evaluation of the delivered doses. [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=160990841 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1002/mp.15880 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 16 StartPage: 7567 Subjects: – SubjectFull: Imaging phantoms Type: general – SubjectFull: Photomultipliers Type: general – SubjectFull: Imaging systems Type: general – SubjectFull: Radiation dosimetry Type: general – SubjectFull: Positron emission tomography Type: general – SubjectFull: Computed tomography Type: general – SubjectFull: Quantitative research Type: general Titles: – TitleFull: Comparison of PMT‐based TF64 and SiPM‐based Vereos PET/CT systems for 90Y imaging and dosimetry optimization: A quantitative study. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Trotta, Nicola – PersonEntity: Name: NameFull: Collette, Benoît – PersonEntity: Name: NameFull: Mathey, Céline – PersonEntity: Name: NameFull: Vierasu, Irina – PersonEntity: Name: NameFull: Bucalau, Ana‐Maria – PersonEntity: Name: NameFull: Verset, Gontran – PersonEntity: Name: NameFull: Moreno‐Reyes, Rodrigo – PersonEntity: Name: NameFull: Goldman, Serge IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 12 Text: Dec2022 Type: published Y: 2022 Identifiers: – Type: issn-print Value: 00942405 Numbering: – Type: volume Value: 49 – Type: issue Value: 12 Titles: – TitleFull: Medical Physics Type: main |
| ResultId | 1 |