Erratum to: Velocity‐selective arterial spin labeling perfusion MRI: A review of the state of the art and recommendations for clinical implementation (Magn Reson Med. 2022; 88:1528–1547).
Saved in:
| Title: | Erratum to: Velocity‐selective arterial spin labeling perfusion MRI: A review of the state of the art and recommendations for clinical implementation (Magn Reson Med. 2022; 88:1528–1547). |
|---|---|
| Authors: | Qin, Qin1 (AUTHOR) qqin1@jhu.edu, Alsop, David C.2 (AUTHOR), Bolar, Divya S.3 (AUTHOR), Hernandez‐Garcia, Luis4 (AUTHOR), Meakin, James5 (AUTHOR), Liu, Dapeng1 (AUTHOR), Nayak, Krishna S.6 (AUTHOR), Schmid, Sophie7 (AUTHOR), van Osch, Matthias J. P.7 (AUTHOR), Wong, Eric C.3 (AUTHOR), Woods, Joseph G.3 (AUTHOR), Zaharchuk, Greg8 (AUTHOR), Zhao, Moss Y.8 (AUTHOR), Zun, Zungho9 (AUTHOR), Guo, Jia10 (AUTHOR) |
| Source: | Magnetic Resonance in Medicine. Mar2023, Vol. 89 Issue 3, p1278-1279. 2p. |
| Subjects: | Spin labels, Magnetic resonance imaging, Perfusion, Blood flow |
| Abstract: | In the above referenced article, we would like to correct the error of the misplaced SI SB B sb term and update the Equation (1) as well as the first sentence of Section 9.5 as below: 9.5 Quantification of VSASL The blood flow (BF, in mL/100 g/min) can be quantified based on the kinetic model as: 1 HT ht Erratum to: Velocity-selective arterial spin labeling perfusion MRI: A review of the state of the art and recommendations for clinical implementation (Magn Reson Med. [Extracted from the article] |
| Copyright of Magnetic Resonance in Medicine is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
|
Full text is not displayed to guests.
Login for full access.
|
|
| FullText | Links: – Type: pdflink Text: Availability: 1 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 160990894 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Erratum to: Velocity‐selective arterial spin labeling perfusion MRI: A review of the state of the art and recommendations for clinical implementation (Magn Reson Med. 2022; 88:1528–1547). – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Qin%2C+Qin%22">Qin, Qin</searchLink><relatesTo>1</relatesTo> (AUTHOR)<i> qqin1@jhu.edu</i><br /><searchLink fieldCode="AR" term="%22Alsop%2C+David+C%2E%22">Alsop, David C.</searchLink><relatesTo>2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Bolar%2C+Divya+S%2E%22">Bolar, Divya S.</searchLink><relatesTo>3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Hernandez‐Garcia%2C+Luis%22">Hernandez‐Garcia, Luis</searchLink><relatesTo>4</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Meakin%2C+James%22">Meakin, James</searchLink><relatesTo>5</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Liu%2C+Dapeng%22">Liu, Dapeng</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Nayak%2C+Krishna+S%2E%22">Nayak, Krishna S.</searchLink><relatesTo>6</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Schmid%2C+Sophie%22">Schmid, Sophie</searchLink><relatesTo>7</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22van+Osch%2C+Matthias+J%2E+P%2E%22">van Osch, Matthias J. P.</searchLink><relatesTo>7</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Wong%2C+Eric+C%2E%22">Wong, Eric C.</searchLink><relatesTo>3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Woods%2C+Joseph+G%2E%22">Woods, Joseph G.</searchLink><relatesTo>3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Zaharchuk%2C+Greg%22">Zaharchuk, Greg</searchLink><relatesTo>8</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Zhao%2C+Moss+Y%2E%22">Zhao, Moss Y.</searchLink><relatesTo>8</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Zun%2C+Zungho%22">Zun, Zungho</searchLink><relatesTo>9</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Guo%2C+Jia%22">Guo, Jia</searchLink><relatesTo>10</relatesTo> (AUTHOR) – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Magnetic+Resonance+in+Medicine%22">Magnetic Resonance in Medicine</searchLink>. Mar2023, Vol. 89 Issue 3, p1278-1279. 2p. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22Spin+labels%22">Spin labels</searchLink><br /><searchLink fieldCode="DE" term="%22Magnetic+resonance+imaging%22">Magnetic resonance imaging</searchLink><br /><searchLink fieldCode="DE" term="%22Perfusion%22">Perfusion</searchLink><br /><searchLink fieldCode="DE" term="%22Blood+flow%22">Blood flow</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: In the above referenced article, we would like to correct the error of the misplaced SI SB B sb term and update the Equation (1) as well as the first sentence of Section 9.5 as below: 9.5 Quantification of VSASL The blood flow (BF, in mL/100 g/min) can be quantified based on the kinetic model as: 1 HT <math display="block" overflow="scroll" altimg="urn:x-wiley:07403194:media:mrm29504:mrm29504-math-0001" xmlns="http://www.w3.org/1998/Math/MathML"><semantics><mrow><mi mathvariant="normal">BF</mi><mo linebreak="goodbreak">=</mo><mfrac><mrow><mn>6000</mn><mo>-</mo><mi mathvariant="normal"> </mi><mo>-</mo><mo> </mo><mi mathvariant="normal">S</mi><mo>-</mo><msup><mi>e</mi><mfrac><mi mathvariant="normal">TI</mi><msub><mi mathvariant="normal">T</mi><mrow><mn>1</mn><mo>,</mo><mtext>blood</mtext></mrow></msub></mfrac></msup></mrow><mrow><mn>2</mn><mo>-</mo><mi mathvariant="normal"> </mi><mo>-</mo><mi mathvariant="normal"> </mi><mo>-</mo><msub><mi mathvariant="normal">SI</mi><mi mathvariant="normal">PD</mi></msub><mo>-</mo><msub><mi mathvariant="normal">SI</mi><mi mathvariant="normal">B</mi></msub></mrow></mfrac></mrow><annotation encoding="WINDOWS-1252">$$ \mathrm{BF}=\frac{6000\cdot \uplambda \cdot \Delta \mathrm{S}\cdot {e}^{\frac{\mathrm{T}\mathrm{I}}{{\mathrm{T}} {1,\mathrm{blood}}}}}{2\cdot \upalpha \cdot \uptau \cdot {\mathrm{SI}} {\mathrm{PD}}\cdot {\mathrm{SI}} {\mathrm{B}}} $$</annotation></semantics></math> ht Erratum to: Velocity-selective arterial spin labeling perfusion MRI: A review of the state of the art and recommendations for clinical implementation (Magn Reson Med. [Extracted from the article] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of Magnetic Resonance in Medicine is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=160990894 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1002/mrm.29504 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 2 StartPage: 1278 Subjects: – SubjectFull: Spin labels Type: general – SubjectFull: Magnetic resonance imaging Type: general – SubjectFull: Perfusion Type: general – SubjectFull: Blood flow Type: general Titles: – TitleFull: Erratum to: Velocity‐selective arterial spin labeling perfusion MRI: A review of the state of the art and recommendations for clinical implementation (Magn Reson Med. 2022; 88:1528–1547). Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Qin, Qin – PersonEntity: Name: NameFull: Alsop, David C. – PersonEntity: Name: NameFull: Bolar, Divya S. – PersonEntity: Name: NameFull: Hernandez‐Garcia, Luis – PersonEntity: Name: NameFull: Meakin, James – PersonEntity: Name: NameFull: Liu, Dapeng – PersonEntity: Name: NameFull: Nayak, Krishna S. – PersonEntity: Name: NameFull: Schmid, Sophie – PersonEntity: Name: NameFull: van Osch, Matthias J. P. – PersonEntity: Name: NameFull: Wong, Eric C. – PersonEntity: Name: NameFull: Woods, Joseph G. – PersonEntity: Name: NameFull: Zaharchuk, Greg – PersonEntity: Name: NameFull: Zhao, Moss Y. – PersonEntity: Name: NameFull: Zun, Zungho – PersonEntity: Name: NameFull: Guo, Jia IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 03 Text: Mar2023 Type: published Y: 2023 Identifiers: – Type: issn-print Value: 07403194 Numbering: – Type: volume Value: 89 – Type: issue Value: 3 Titles: – TitleFull: Magnetic Resonance in Medicine Type: main |
| ResultId | 1 |