Possibility for improving the performance of a differential pneumatic comparator by inclining the measuring nozzle.

Saved in:
Bibliographic Details
Title: Possibility for improving the performance of a differential pneumatic comparator by inclining the measuring nozzle.
Authors: Burazer, Jela1 (AUTHOR) jburazer@mas.bg.ac.rs, Skoko, Dragiša1 (AUTHOR) dskoko@mas.bg.ac.rs, Bukurov, Maša2 (AUTHOR) mbukurov@uns.ac.rs, Novković, Đorđe1 (AUTHOR) dnovkovic@mas.bg.ac.rs, Adžić, Vuk1 (AUTHOR) vadzic@mas.bg.ac.rs, Lečić, Milan1 (AUTHOR) mlecic@mas.bg.ac.rs, Vorotović, Goran1 (AUTHOR) gvorotovic@mas.bg.ac.rs
Source: Measurement (02632241). Feb2023, Vol. 208, pN.PAG-N.PAG. 1p.
Subjects: Comparator circuits, Pneumatic control, Machine parts, Nozzles, Possibility
Abstract: Pneumatic control has found irreplaceable applications in the control of machine parts, where high accuracy is required. One of the problems that occur with the long-term use of pneumatic comparator is the fouling of its head. This requires interruption of pneumatic comparator's work for maintenance, i.e., cleaning the device from accumulated impurities. Fouling of the comparator head is the consequence of the vacuum in the area between the measuring nozzle and the measured workpiece. This paper studies the possibility of vacuum reduction — both in its size and strength by varying the measuring nozzle inclination angle. The research is conducted experimentally via test rig designed for this purpose. The inclination angle of the measuring nozzle was varied from 1 °to 7 °, with the steps of 1 °. The analysis comprises the influence of the measuring nozzle inclination on both radial and the axial pressure distribution on the workpiece surface, as well as the corresponding consequences on the comparator's pneumatic sensitivity and its application range. Experimental results for four different supply pressures and six axial distances between the measuring nozzle front cross-section and the workpiece surface are presented. It is shown that it is possible to reduce the size of the vacuum zone and decrease the vacuum by inclining the measuring nozzle by a certain angle, depending on the supply pressure p o. For a certain value of the supply pressure, it is also possible to move the vacuum zone away from the measuring nozzle's axis when the nozzle is inclined by the optimal angle. On the downside, inclination of the measuring nozzle leads to a decrease in the application range of the comparator. • Inclination of measuring nozzle can influence the vacuum zone properties. • Inclination of nozzle can reduce the impurities gathering on the comparator's head. • Nozzle inclination decreases application range and precision of a comparator. • Nozzle inclination can cause difficulty in comparator application range calculation. [ABSTRACT FROM AUTHOR]
Copyright of Measurement (02632241) is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 161740059
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Possibility for improving the performance of a differential pneumatic comparator by inclining the measuring nozzle.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Burazer%2C+Jela%22">Burazer, Jela</searchLink><relatesTo>1</relatesTo> (AUTHOR)<i> jburazer@mas.bg.ac.rs</i><br /><searchLink fieldCode="AR" term="%22Skoko%2C+Dragiša%22">Skoko, Dragiša</searchLink><relatesTo>1</relatesTo> (AUTHOR)<i> dskoko@mas.bg.ac.rs</i><br /><searchLink fieldCode="AR" term="%22Bukurov%2C+Maša%22">Bukurov, Maša</searchLink><relatesTo>2</relatesTo> (AUTHOR)<i> mbukurov@uns.ac.rs</i><br /><searchLink fieldCode="AR" term="%22Novković%2C+Đorđe%22">Novković, Đorđe</searchLink><relatesTo>1</relatesTo> (AUTHOR)<i> dnovkovic@mas.bg.ac.rs</i><br /><searchLink fieldCode="AR" term="%22Adžić%2C+Vuk%22">Adžić, Vuk</searchLink><relatesTo>1</relatesTo> (AUTHOR)<i> vadzic@mas.bg.ac.rs</i><br /><searchLink fieldCode="AR" term="%22Lečić%2C+Milan%22">Lečić, Milan</searchLink><relatesTo>1</relatesTo> (AUTHOR)<i> mlecic@mas.bg.ac.rs</i><br /><searchLink fieldCode="AR" term="%22Vorotović%2C+Goran%22">Vorotović, Goran</searchLink><relatesTo>1</relatesTo> (AUTHOR)<i> gvorotovic@mas.bg.ac.rs</i>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Measurement+%2802632241%29%22">Measurement (02632241)</searchLink>. Feb2023, Vol. 208, pN.PAG-N.PAG. 1p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Comparator+circuits%22">Comparator circuits</searchLink><br /><searchLink fieldCode="DE" term="%22Pneumatic+control%22">Pneumatic control</searchLink><br /><searchLink fieldCode="DE" term="%22Machine+parts%22">Machine parts</searchLink><br /><searchLink fieldCode="DE" term="%22Nozzles%22">Nozzles</searchLink><br /><searchLink fieldCode="DE" term="%22Possibility%22">Possibility</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Pneumatic control has found irreplaceable applications in the control of machine parts, where high accuracy is required. One of the problems that occur with the long-term use of pneumatic comparator is the fouling of its head. This requires interruption of pneumatic comparator's work for maintenance, i.e., cleaning the device from accumulated impurities. Fouling of the comparator head is the consequence of the vacuum in the area between the measuring nozzle and the measured workpiece. This paper studies the possibility of vacuum reduction — both in its size and strength by varying the measuring nozzle inclination angle. The research is conducted experimentally via test rig designed for this purpose. The inclination angle of the measuring nozzle was varied from 1 °to 7 °, with the steps of 1 °. The analysis comprises the influence of the measuring nozzle inclination on both radial and the axial pressure distribution on the workpiece surface, as well as the corresponding consequences on the comparator's pneumatic sensitivity and its application range. Experimental results for four different supply pressures and six axial distances between the measuring nozzle front cross-section and the workpiece surface are presented. It is shown that it is possible to reduce the size of the vacuum zone and decrease the vacuum by inclining the measuring nozzle by a certain angle, depending on the supply pressure p o. For a certain value of the supply pressure, it is also possible to move the vacuum zone away from the measuring nozzle's axis when the nozzle is inclined by the optimal angle. On the downside, inclination of the measuring nozzle leads to a decrease in the application range of the comparator. • Inclination of measuring nozzle can influence the vacuum zone properties. • Inclination of nozzle can reduce the impurities gathering on the comparator's head. • Nozzle inclination decreases application range and precision of a comparator. • Nozzle inclination can cause difficulty in comparator application range calculation. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Measurement (02632241) is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=161740059
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1016/j.measurement.2022.112415
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 1
        StartPage: N.PAG
    Subjects:
      – SubjectFull: Comparator circuits
        Type: general
      – SubjectFull: Pneumatic control
        Type: general
      – SubjectFull: Machine parts
        Type: general
      – SubjectFull: Nozzles
        Type: general
      – SubjectFull: Possibility
        Type: general
    Titles:
      – TitleFull: Possibility for improving the performance of a differential pneumatic comparator by inclining the measuring nozzle.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Burazer, Jela
      – PersonEntity:
          Name:
            NameFull: Skoko, Dragiša
      – PersonEntity:
          Name:
            NameFull: Bukurov, Maša
      – PersonEntity:
          Name:
            NameFull: Novković, Đorđe
      – PersonEntity:
          Name:
            NameFull: Adžić, Vuk
      – PersonEntity:
          Name:
            NameFull: Lečić, Milan
      – PersonEntity:
          Name:
            NameFull: Vorotović, Goran
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 28
              M: 02
              Text: Feb2023
              Type: published
              Y: 2023
          Identifiers:
            – Type: issn-print
              Value: 02632241
          Numbering:
            – Type: volume
              Value: 208
          Titles:
            – TitleFull: Measurement (02632241)
              Type: main
ResultId 1