Myeloma bone disease imaging on a 1st-generation clinical photon-counting detector CT vs. 2nd-generation dual-source dual-energy CT.

Saved in:
Bibliographic Details
Title: Myeloma bone disease imaging on a 1st-generation clinical photon-counting detector CT vs. 2nd-generation dual-source dual-energy CT.
Authors: Winkelmann, Moritz T.1 moritz.winkelmann@med.uni-tuebingen.de, Hagen, Florian1, Le-Yannou, Lucie1, Weiss, Jakob2, Riffel, Philipp3, Gutjahr, Ralf4, Faby, Sebastian4, Nikolaou, Konstantin1, Horger, Marius1
Source: European Radiology. Apr2023, Vol. 33 Issue 4, p2415-2425. 11p. 2 Black and White Photographs, 5 Charts, 2 Graphs, 1 Map.
Subjects: Multiple myeloma diagnosis, Microstructure, Photons, Pelvic bones, Radiology
Abstract: Objective: Subjective and objective image quality comparison of bone microstructure and disease-related abnormalities in multiple myeloma patients using a 1st-generation dual-source photon-counting detector CT(DS-PCD-CT) and a 2nd-generation dual-source dual-energy (energy-integrating detector) CT (DS-EID-CT). Methods: Fifty multiple myeloma patients (mean age 67.7 ± 10.9 years,16 females) were prospectively enrolled. Unenhanced whole-body CTs were clinically indicated and performed on DS-EID-CT and DS-PCD-CT (median time difference: 12 months). DS-PCD-CT was performed in Quantumplus UHR mode and DS-EID-CT was performed using dual-energy mode. DS-PCD-CT kernel was set at Br64 with Quantum iterative reconstruction strength Q1; for DS-EID-CT a comparable I70f kernel with SAFIRE iterative reconstruction strength 1 was used. Two independent radiologists assessed image quality subjectively using a 5-point Likert scale considering delineation and sharpness of trabecular bone and lytic bone lesions in the spine and pelvic bones. Additionally, ImageJ was used for quantification of bony septa inside the cancellous bone and through or the edges of osteolysis. Results: Overall quality as well as detectability and sharpness in the delineation of lytic bone lesions were superior for DS-PCD-CT compared with DS-EID-CT (p < 0.0001). The inter-reader agreement for subjective image quality readings showed excellent consistency(α = 94.2–98.8). CTDI and DLP mean values for DS-PCD-CT and DS-EID-CT were 1107.4 ± 247.6 mGy*cm and 8.2 ± 1.8 mGy vs. 1344.3 ± 204.6 mGy*cm and 10.1 ± 1.9 mGy. The quantitative metric for bone microstructure in the femoral head showed significantly better visualization of trabeculae in DS-PCD-CT compared with DS-EID-CT (p < 0.0001). Quantitative analyses of edge sharpness of osteolysis showed significant steeper edges for DS-PCD-CT (p < 0.0001). Conclusion: DS-PCD-CT significantly improves spatial resolution of bony microstructure and lytic bone lesions compared to DS-EID-CT. Key Points: • Application of photon-counting detector CT is superior to dual-source dual-energy integrating detector in clinical workup of multiple myeloma patients. • Compared to energy integrating detectors, photon-counting detectors significantly increase the spatial resolution of bone microstructure including disease-related lytic bone lesions in patients with multiple myeloma. [ABSTRACT FROM AUTHOR]
Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Full text is not displayed to guests.
FullText Links:
  – Type: pdflink
Text:
  Availability: 1
Header DbId: egs
DbLabel: Engineering Source
An: 162470404
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Myeloma bone disease imaging on a 1st-generation clinical photon-counting detector CT vs. 2nd-generation dual-source dual-energy CT.
– Name: Author
  Label: Authors
  Group: Au
  Data: &lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Winkelmann%2C+Moritz+T%2E%22&quot;&gt;Winkelmann, Moritz T.&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt;&lt;i&gt; moritz.winkelmann@med.uni-tuebingen.de&lt;/i&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Hagen%2C+Florian%22&quot;&gt;Hagen, Florian&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Le-Yannou%2C+Lucie%22&quot;&gt;Le-Yannou, Lucie&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Weiss%2C+Jakob%22&quot;&gt;Weiss, Jakob&lt;/searchLink&gt;&lt;relatesTo&gt;2&lt;/relatesTo&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Riffel%2C+Philipp%22&quot;&gt;Riffel, Philipp&lt;/searchLink&gt;&lt;relatesTo&gt;3&lt;/relatesTo&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Gutjahr%2C+Ralf%22&quot;&gt;Gutjahr, Ralf&lt;/searchLink&gt;&lt;relatesTo&gt;4&lt;/relatesTo&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Faby%2C+Sebastian%22&quot;&gt;Faby, Sebastian&lt;/searchLink&gt;&lt;relatesTo&gt;4&lt;/relatesTo&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Nikolaou%2C+Konstantin%22&quot;&gt;Nikolaou, Konstantin&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Horger%2C+Marius%22&quot;&gt;Horger, Marius&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt;
– Name: TitleSource
  Label: Source
  Group: Src
  Data: &lt;searchLink fieldCode=&quot;JN&quot; term=&quot;%22European+Radiology%22&quot;&gt;European Radiology&lt;/searchLink&gt;. Apr2023, Vol. 33 Issue 4, p2415-2425. 11p. 2 Black and White Photographs, 5 Charts, 2 Graphs, 1 Map.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: &lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Multiple+myeloma+diagnosis%22&quot;&gt;Multiple myeloma diagnosis&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Microstructure%22&quot;&gt;Microstructure&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Photons%22&quot;&gt;Photons&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Pelvic+bones%22&quot;&gt;Pelvic bones&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Radiology%22&quot;&gt;Radiology&lt;/searchLink&gt;
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Objective: Subjective and objective image quality comparison of bone microstructure and disease-related abnormalities in multiple myeloma patients using a 1st-generation dual-source photon-counting detector CT(DS-PCD-CT) and a 2nd-generation dual-source dual-energy (energy-integrating detector) CT (DS-EID-CT). Methods: Fifty multiple myeloma patients (mean age 67.7 &#177; 10.9 years,16 females) were prospectively enrolled. Unenhanced whole-body CTs were clinically indicated and performed on DS-EID-CT and DS-PCD-CT (median time difference: 12 months). DS-PCD-CT was performed in Quantumplus UHR mode and DS-EID-CT was performed using dual-energy mode. DS-PCD-CT kernel was set at Br64 with Quantum iterative reconstruction strength Q1; for DS-EID-CT a comparable I70f kernel with SAFIRE iterative reconstruction strength 1 was used. Two independent radiologists assessed image quality subjectively using a 5-point Likert scale considering delineation and sharpness of trabecular bone and lytic bone lesions in the spine and pelvic bones. Additionally, ImageJ was used for quantification of bony septa inside the cancellous bone and through or the edges of osteolysis. Results: Overall quality as well as detectability and sharpness in the delineation of lytic bone lesions were superior for DS-PCD-CT compared with DS-EID-CT (p &lt; 0.0001). The inter-reader agreement for subjective image quality readings showed excellent consistency(α = 94.2–98.8). CTDI and DLP mean values for DS-PCD-CT and DS-EID-CT were 1107.4 &#177; 247.6 mGy*cm and 8.2 &#177; 1.8 mGy vs. 1344.3 &#177; 204.6 mGy*cm and 10.1 &#177; 1.9 mGy. The quantitative metric for bone microstructure in the femoral head showed significantly better visualization of trabeculae in DS-PCD-CT compared with DS-EID-CT (p &lt; 0.0001). Quantitative analyses of edge sharpness of osteolysis showed significant steeper edges for DS-PCD-CT (p &lt; 0.0001). Conclusion: DS-PCD-CT significantly improves spatial resolution of bony microstructure and lytic bone lesions compared to DS-EID-CT. Key Points: • Application of photon-counting detector CT is superior to dual-source dual-energy integrating detector in clinical workup of multiple myeloma patients. • Compared to energy integrating detectors, photon-counting detectors significantly increase the spatial resolution of bone microstructure including disease-related lytic bone lesions in patients with multiple myeloma. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: &lt;i&gt;Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder&#39;s express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.&lt;/i&gt; (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=162470404
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1007/s00330-022-09225-0
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 11
        StartPage: 2415
    Subjects:
      – SubjectFull: Multiple myeloma diagnosis
        Type: general
      – SubjectFull: Microstructure
        Type: general
      – SubjectFull: Photons
        Type: general
      – SubjectFull: Pelvic bones
        Type: general
      – SubjectFull: Radiology
        Type: general
    Titles:
      – TitleFull: Myeloma bone disease imaging on a 1st-generation clinical photon-counting detector CT vs. 2nd-generation dual-source dual-energy CT.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Winkelmann, Moritz T.
      – PersonEntity:
          Name:
            NameFull: Hagen, Florian
      – PersonEntity:
          Name:
            NameFull: Le-Yannou, Lucie
      – PersonEntity:
          Name:
            NameFull: Weiss, Jakob
      – PersonEntity:
          Name:
            NameFull: Riffel, Philipp
      – PersonEntity:
          Name:
            NameFull: Gutjahr, Ralf
      – PersonEntity:
          Name:
            NameFull: Faby, Sebastian
      – PersonEntity:
          Name:
            NameFull: Nikolaou, Konstantin
      – PersonEntity:
          Name:
            NameFull: Horger, Marius
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 04
              Text: Apr2023
              Type: published
              Y: 2023
          Identifiers:
            – Type: issn-print
              Value: 09387994
          Numbering:
            – Type: volume
              Value: 33
            – Type: issue
              Value: 4
          Titles:
            – TitleFull: European Radiology
              Type: main
ResultId 1