Initial experience on abdominal photon-counting computed tomography in clinical routine: general image quality and dose exposure.

Saved in:
Bibliographic Details
Title: Initial experience on abdominal photon-counting computed tomography in clinical routine: general image quality and dose exposure.
Authors: Becker, Benjamin V.1,2 benjamin3becker@bundeswehr.org, Kaatsch, Hanns Leonhard1,2, Nestler, Kai1, Overhoff, Daniel1,3, Schneider, Julian1, Dillinger, Daniel4, Piechotka, Joel1, Brockmann, Marc A.5, Ullmann, Reinhard2, Port, Matthias2, Scherthan, Harry2, Waldeck, Stephan1,5
Source: European Radiology. Apr2023, Vol. 33 Issue 4, p2461-2468. 8p. 1 Black and White Photograph, 2 Charts, 2 Graphs.
Subjects: Computed tomography, DNA, Radiobiology, Likert scale, Blood cells
Abstract: Objectives: Photon-counting computed tomography has lately found its way into clinical routine. The new technique could offer substantial improvements regarding general image quality, image noise, and radiation dose reduction. This study evaluated the first abdominal examinations in clinical routine and compared the results to conventional computed tomography. Methods: In this single-center retrospective study, 66 patients underwent photon-counting and conventional abdominal CT. Four radiologists assessed general image quality, image noise, and image artifacts. Signal-to-noise ratio and dose properties of both techniques within the clinical application were compared. An ex vivo phantom study revealed the radiobiological impact by means of DNA double-strand break foci in peripheral blood cells by enumerating γ-H2AX+53BP1 foci. Results: General image quality in accordance with the Likert scale was found superior for photon-counting CT (4.74 ± 0.46 vs. 4.25 ± 0.54; p < 0.001). Signal-to-noise ratio (p < 0.001) and also dose exposure were higher for photon-counting CT (DLP: 419.2 ± 162.2 vs. 372.3 ± 236.6 mGy*cm; p = 0.0435). CT exposure resulted in significantly increased DNA damage in comparison to sham control (p < 0.001). Investigation of the average foci per cell and radiation-induced foci numbers revealed significantly elevated numbers (p = 0.004 and p < 0.0001, respectively) after photon-counting CT. Conclusion: Photon-counting CT in abdominal examinations showed superior results regarding general image quality and signal-to-noise ratio in clinical routine. However, this seems to be traded for a significantly higher dose exposure and corresponding double-strand break frequency. Optimization of standard protocols in further clinical applications is required to find a compromise regarding picture quality and dose exposure. Key Points: • Photon-counting computed tomography promises to enhance the diagnostic potential of medical imaging in clinical routine. • Retrospective single-center study showed superior general image quality accompanied by higher dose exposure in initial abdominal PCCT protocols compared to state-of-the-art conventional CT. • A simultaneous ex vivo phantom study revealed correspondingly increased frequencies of DNA double-strand breaks after PCCT. [ABSTRACT FROM AUTHOR]
Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Full text is not displayed to guests.
FullText Links:
  – Type: pdflink
Text:
  Availability: 1
Header DbId: egs
DbLabel: Engineering Source
An: 162470453
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Initial experience on abdominal photon-counting computed tomography in clinical routine: general image quality and dose exposure.
– Name: Author
  Label: Authors
  Group: Au
  Data: &lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Becker%2C+Benjamin+V%2E%22&quot;&gt;Becker, Benjamin V.&lt;/searchLink&gt;&lt;relatesTo&gt;1,2&lt;/relatesTo&gt;&lt;i&gt; benjamin3becker@bundeswehr.org&lt;/i&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Kaatsch%2C+Hanns+Leonhard%22&quot;&gt;Kaatsch, Hanns Leonhard&lt;/searchLink&gt;&lt;relatesTo&gt;1,2&lt;/relatesTo&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Nestler%2C+Kai%22&quot;&gt;Nestler, Kai&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Overhoff%2C+Daniel%22&quot;&gt;Overhoff, Daniel&lt;/searchLink&gt;&lt;relatesTo&gt;1,3&lt;/relatesTo&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Schneider%2C+Julian%22&quot;&gt;Schneider, Julian&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Dillinger%2C+Daniel%22&quot;&gt;Dillinger, Daniel&lt;/searchLink&gt;&lt;relatesTo&gt;4&lt;/relatesTo&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Piechotka%2C+Joel%22&quot;&gt;Piechotka, Joel&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Brockmann%2C+Marc+A%2E%22&quot;&gt;Brockmann, Marc A.&lt;/searchLink&gt;&lt;relatesTo&gt;5&lt;/relatesTo&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Ullmann%2C+Reinhard%22&quot;&gt;Ullmann, Reinhard&lt;/searchLink&gt;&lt;relatesTo&gt;2&lt;/relatesTo&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Port%2C+Matthias%22&quot;&gt;Port, Matthias&lt;/searchLink&gt;&lt;relatesTo&gt;2&lt;/relatesTo&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Scherthan%2C+Harry%22&quot;&gt;Scherthan, Harry&lt;/searchLink&gt;&lt;relatesTo&gt;2&lt;/relatesTo&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Waldeck%2C+Stephan%22&quot;&gt;Waldeck, Stephan&lt;/searchLink&gt;&lt;relatesTo&gt;1,5&lt;/relatesTo&gt;
– Name: TitleSource
  Label: Source
  Group: Src
  Data: &lt;searchLink fieldCode=&quot;JN&quot; term=&quot;%22European+Radiology%22&quot;&gt;European Radiology&lt;/searchLink&gt;. Apr2023, Vol. 33 Issue 4, p2461-2468. 8p. 1 Black and White Photograph, 2 Charts, 2 Graphs.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: &lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Computed+tomography%22&quot;&gt;Computed tomography&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22DNA%22&quot;&gt;DNA&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Radiobiology%22&quot;&gt;Radiobiology&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Likert+scale%22&quot;&gt;Likert scale&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Blood+cells%22&quot;&gt;Blood cells&lt;/searchLink&gt;
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Objectives: Photon-counting computed tomography has lately found its way into clinical routine. The new technique could offer substantial improvements regarding general image quality, image noise, and radiation dose reduction. This study evaluated the first abdominal examinations in clinical routine and compared the results to conventional computed tomography. Methods: In this single-center retrospective study, 66 patients underwent photon-counting and conventional abdominal CT. Four radiologists assessed general image quality, image noise, and image artifacts. Signal-to-noise ratio and dose properties of both techniques within the clinical application were compared. An ex vivo phantom study revealed the radiobiological impact by means of DNA double-strand break foci in peripheral blood cells by enumerating γ-H2AX+53BP1 foci. Results: General image quality in accordance with the Likert scale was found superior for photon-counting CT (4.74 &#177; 0.46 vs. 4.25 &#177; 0.54; p &lt; 0.001). Signal-to-noise ratio (p &lt; 0.001) and also dose exposure were higher for photon-counting CT (DLP: 419.2 &#177; 162.2 vs. 372.3 &#177; 236.6 mGy*cm; p = 0.0435). CT exposure resulted in significantly increased DNA damage in comparison to sham control (p &lt; 0.001). Investigation of the average foci per cell and radiation-induced foci numbers revealed significantly elevated numbers (p = 0.004 and p &lt; 0.0001, respectively) after photon-counting CT. Conclusion: Photon-counting CT in abdominal examinations showed superior results regarding general image quality and signal-to-noise ratio in clinical routine. However, this seems to be traded for a significantly higher dose exposure and corresponding double-strand break frequency. Optimization of standard protocols in further clinical applications is required to find a compromise regarding picture quality and dose exposure. Key Points: • Photon-counting computed tomography promises to enhance the diagnostic potential of medical imaging in clinical routine. • Retrospective single-center study showed superior general image quality accompanied by higher dose exposure in initial abdominal PCCT protocols compared to state-of-the-art conventional CT. • A simultaneous ex vivo phantom study revealed correspondingly increased frequencies of DNA double-strand breaks after PCCT. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: &lt;i&gt;Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder&#39;s express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.&lt;/i&gt; (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=162470453
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1007/s00330-022-09278-1
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 8
        StartPage: 2461
    Subjects:
      – SubjectFull: Computed tomography
        Type: general
      – SubjectFull: DNA
        Type: general
      – SubjectFull: Radiobiology
        Type: general
      – SubjectFull: Likert scale
        Type: general
      – SubjectFull: Blood cells
        Type: general
    Titles:
      – TitleFull: Initial experience on abdominal photon-counting computed tomography in clinical routine: general image quality and dose exposure.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Becker, Benjamin V.
      – PersonEntity:
          Name:
            NameFull: Kaatsch, Hanns Leonhard
      – PersonEntity:
          Name:
            NameFull: Nestler, Kai
      – PersonEntity:
          Name:
            NameFull: Overhoff, Daniel
      – PersonEntity:
          Name:
            NameFull: Schneider, Julian
      – PersonEntity:
          Name:
            NameFull: Dillinger, Daniel
      – PersonEntity:
          Name:
            NameFull: Piechotka, Joel
      – PersonEntity:
          Name:
            NameFull: Brockmann, Marc A.
      – PersonEntity:
          Name:
            NameFull: Ullmann, Reinhard
      – PersonEntity:
          Name:
            NameFull: Port, Matthias
      – PersonEntity:
          Name:
            NameFull: Scherthan, Harry
      – PersonEntity:
          Name:
            NameFull: Waldeck, Stephan
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 04
              Text: Apr2023
              Type: published
              Y: 2023
          Identifiers:
            – Type: issn-print
              Value: 09387994
          Numbering:
            – Type: volume
              Value: 33
            – Type: issue
              Value: 4
          Titles:
            – TitleFull: European Radiology
              Type: main
ResultId 1