Behind Shield Blunt Trauma: Characterizing the Back-Face Deformation of Shields with a Focus on Upper Limb Loading.

Saved in:
Bibliographic Details
Title: Behind Shield Blunt Trauma: Characterizing the Back-Face Deformation of Shields with a Focus on Upper Limb Loading.
Authors: de Lange, J. E.1 (AUTHOR), Burrows, L. J.1 (AUTHOR), Binette, J.-S.2 (AUTHOR), Quenneville, C. E.1,3 (AUTHOR) quennev@mcmaster.ca
Source: Annals of Biomedical Engineering. Jun2023, Vol. 51 Issue 6, p1331-1342. 12p.
Subjects: Wrist, Blunt trauma, Digital image correlation, Forelimb, Deformations (Mechanics)
Abstract: Shield back-face deformation (BFD) is the result of composite ballistic shields deflecting or absorbing a projectile's energy and deforming towards the user. BFD can result in localized loading to the upper extremity, where the shield is secured to the user. An augmented anthropomorphic test device upper extremity was used to quantify this applied load. Four locations along the upper extremity were tested—the hand, wrist, forearm, and elbow—for investigating differing boundary conditions and their effect on resultant load. Varying stand-off distances, the distance between the back of the shield and the force sensor, were investigated. Digital image correlation was also conducted to measure the dynamic displacement of the shield. The mean peak back-face velocity of the shield was 208.4 ± 38.8 m/s, while the average affected area was 1505 ± 158.3 mm2. Impulse was not significantly affected by anatomical location for the same stand-off distance; however, as stand-off distance decreased, the measured force significantly increased (p < 0.05). Notably, impact duration did not differ significantly for any of the impact scenarios. This is the first step in developing injury criteria for this region resulting from behind shield blunt trauma, and these data will be used for developing injury thresholds in post-mortem human surrogates. [ABSTRACT FROM AUTHOR]
Copyright of Annals of Biomedical Engineering is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Full text is not displayed to guests.
FullText Links:
  – Type: pdflink
Text:
  Availability: 1
Header DbId: egs
DbLabel: Engineering Source
An: 163726837
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Behind Shield Blunt Trauma: Characterizing the Back-Face Deformation of Shields with a Focus on Upper Limb Loading.
– Name: Author
  Label: Authors
  Group: Au
  Data: &lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22de+Lange%2C+J%2E+E%2E%22&quot;&gt;de Lange, J. E.&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Burrows%2C+L%2E+J%2E%22&quot;&gt;Burrows, L. J.&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Binette%2C+J%2E-S%2E%22&quot;&gt;Binette, J.-S.&lt;/searchLink&gt;&lt;relatesTo&gt;2&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Quenneville%2C+C%2E+E%2E%22&quot;&gt;Quenneville, C. E.&lt;/searchLink&gt;&lt;relatesTo&gt;1,3&lt;/relatesTo&gt; (AUTHOR)&lt;i&gt; quennev@mcmaster.ca&lt;/i&gt;
– Name: TitleSource
  Label: Source
  Group: Src
  Data: &lt;searchLink fieldCode=&quot;JN&quot; term=&quot;%22Annals+of+Biomedical+Engineering%22&quot;&gt;Annals of Biomedical Engineering&lt;/searchLink&gt;. Jun2023, Vol. 51 Issue 6, p1331-1342. 12p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: &lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Wrist%22&quot;&gt;Wrist&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Blunt+trauma%22&quot;&gt;Blunt trauma&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Digital+image+correlation%22&quot;&gt;Digital image correlation&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Forelimb%22&quot;&gt;Forelimb&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Deformations+%28Mechanics%29%22&quot;&gt;Deformations (Mechanics)&lt;/searchLink&gt;
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Shield back-face deformation (BFD) is the result of composite ballistic shields deflecting or absorbing a projectile&#39;s energy and deforming towards the user. BFD can result in localized loading to the upper extremity, where the shield is secured to the user. An augmented anthropomorphic test device upper extremity was used to quantify this applied load. Four locations along the upper extremity were tested—the hand, wrist, forearm, and elbow—for investigating differing boundary conditions and their effect on resultant load. Varying stand-off distances, the distance between the back of the shield and the force sensor, were investigated. Digital image correlation was also conducted to measure the dynamic displacement of the shield. The mean peak back-face velocity of the shield was 208.4 &#177; 38.8 m/s, while the average affected area was 1505 &#177; 158.3 mm2. Impulse was not significantly affected by anatomical location for the same stand-off distance; however, as stand-off distance decreased, the measured force significantly increased (p &lt; 0.05). Notably, impact duration did not differ significantly for any of the impact scenarios. This is the first step in developing injury criteria for this region resulting from behind shield blunt trauma, and these data will be used for developing injury thresholds in post-mortem human surrogates. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: &lt;i&gt;Copyright of Annals of Biomedical Engineering is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder&#39;s express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.&lt;/i&gt; (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=163726837
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1007/s10439-023-03141-0
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 12
        StartPage: 1331
    Subjects:
      – SubjectFull: Wrist
        Type: general
      – SubjectFull: Blunt trauma
        Type: general
      – SubjectFull: Digital image correlation
        Type: general
      – SubjectFull: Forelimb
        Type: general
      – SubjectFull: Deformations (Mechanics)
        Type: general
    Titles:
      – TitleFull: Behind Shield Blunt Trauma: Characterizing the Back-Face Deformation of Shields with a Focus on Upper Limb Loading.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: de Lange, J. E.
      – PersonEntity:
          Name:
            NameFull: Burrows, L. J.
      – PersonEntity:
          Name:
            NameFull: Binette, J.-S.
      – PersonEntity:
          Name:
            NameFull: Quenneville, C. E.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 06
              Text: Jun2023
              Type: published
              Y: 2023
          Identifiers:
            – Type: issn-print
              Value: 00906964
          Numbering:
            – Type: volume
              Value: 51
            – Type: issue
              Value: 6
          Titles:
            – TitleFull: Annals of Biomedical Engineering
              Type: main
ResultId 1