High resolution imaging with focused kV x‐rays for small animal radio‐neuromodulation.

Saved in:
Bibliographic Details
Title: High resolution imaging with focused kV x‐rays for small animal radio‐neuromodulation.
Authors: Shi, Linxi1 (AUTHOR), Bennett, N. Robert1 (AUTHOR), Nguyen, Eric2 (AUTHOR), MacDonald, Carolyn3 (AUTHOR), Wang, Adam1 (AUTHOR), Liu, Wu2 (AUTHOR) wuliu@stanford.edu
Source: Medical Physics. Jul2023, Vol. 50 Issue 7, p4459-4465. 7p.
Subjects: High resolution imaging, X-rays, Cone beam computed tomography, X-ray scattering, Small-angle X-ray scattering, X-ray imaging
Abstract: Background: High precision radiotherapy with small irradiator size has potential in many treatment applications involving small shallow targets, with small animal radio‐neuromodulation as an intriguing example. A focused kV technique based on novel usage of polycapillary x‐ray lenses can focus x‐ray beams to <0.2 mm in diameter, which is ideal for such uses. Purpose: Such an application also requires high resolution CT images for treatment planning and setup. In this work, we demonstrate the feasibility of using a virtual focal spot generated with an x‐ray lens to perform high‐resolution CBCT acquisition. Method: The experiment with x‐ray lens was set up on an x‐ray tabletop system to generate a virtual focal spot. The flood field images with and without the x‐ray lens were first compared. A pinhole image was acquired for the virtual focal spot and compared with the one acquired with the conventional focal spot without the lens. The planar imaging resolution with and without the lens were evaluated using a line pair resolution phantom. The spatial resolution of the two settings were estimated by reconstructing a 0.15‐mm wire phantom and comparing its full width half maximum (FWHM). A CBCT scan of a rodent head was also acquired to further demonstrate the improved resolution using the x‐ray lens. Result: The proposed imaging setup with x‐ray lens had a limited exposure area of 5 cm by 5 cm on the detector, which was suitable for guiding radio‐neuromodulation to a small target in rodent brain. Compared to conventional imaging acquisition with a measured x‐ray focal spot of 0.395 mm FWHM, the virtual focal spot size was measured at 0.175 mm. The reduction in focal spot size with lens leads to an almost doubled planar imaging resolution and a 26% enhancement in 3D spatial resolution. A realistic CBCT acquisition of a rodent head mimicked the imaging acquisition step for radio‐neuromodulation and further showed the improved visualization for fine structures. Conclusion: This work demonstrated that the focused kV x‐ray technique was capable of generating small focal spot size of <0.2 mm, which substantially improved x‐ray imaging resolution for small animal imaging. [ABSTRACT FROM AUTHOR]
Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Full text is not displayed to guests.
FullText Links:
  – Type: pdflink
Text:
  Availability: 1
Header DbId: egs
DbLabel: Engineering Source
An: 164875861
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: High resolution imaging with focused kV x‐rays for small animal radio‐neuromodulation.
– Name: Author
  Label: Authors
  Group: Au
  Data: &lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Shi%2C+Linxi%22&quot;&gt;Shi, Linxi&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Bennett%2C+N%2E+Robert%22&quot;&gt;Bennett, N. Robert&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Nguyen%2C+Eric%22&quot;&gt;Nguyen, Eric&lt;/searchLink&gt;&lt;relatesTo&gt;2&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22MacDonald%2C+Carolyn%22&quot;&gt;MacDonald, Carolyn&lt;/searchLink&gt;&lt;relatesTo&gt;3&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Wang%2C+Adam%22&quot;&gt;Wang, Adam&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Liu%2C+Wu%22&quot;&gt;Liu, Wu&lt;/searchLink&gt;&lt;relatesTo&gt;2&lt;/relatesTo&gt; (AUTHOR)&lt;i&gt; wuliu@stanford.edu&lt;/i&gt;
– Name: TitleSource
  Label: Source
  Group: Src
  Data: &lt;searchLink fieldCode=&quot;JN&quot; term=&quot;%22Medical+Physics%22&quot;&gt;Medical Physics&lt;/searchLink&gt;. Jul2023, Vol. 50 Issue 7, p4459-4465. 7p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: &lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22High+resolution+imaging%22&quot;&gt;High resolution imaging&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22X-rays%22&quot;&gt;X-rays&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Cone+beam+computed+tomography%22&quot;&gt;Cone beam computed tomography&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22X-ray+scattering%22&quot;&gt;X-ray scattering&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Small-angle+X-ray+scattering%22&quot;&gt;Small-angle X-ray scattering&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22X-ray+imaging%22&quot;&gt;X-ray imaging&lt;/searchLink&gt;
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Background: High precision radiotherapy with small irradiator size has potential in many treatment applications involving small shallow targets, with small animal radio‐neuromodulation as an intriguing example. A focused kV technique based on novel usage of polycapillary x‐ray lenses can focus x‐ray beams to &lt;0.2 mm in diameter, which is ideal for such uses. Purpose: Such an application also requires high resolution CT images for treatment planning and setup. In this work, we demonstrate the feasibility of using a virtual focal spot generated with an x‐ray lens to perform high‐resolution CBCT acquisition. Method: The experiment with x‐ray lens was set up on an x‐ray tabletop system to generate a virtual focal spot. The flood field images with and without the x‐ray lens were first compared. A pinhole image was acquired for the virtual focal spot and compared with the one acquired with the conventional focal spot without the lens. The planar imaging resolution with and without the lens were evaluated using a line pair resolution phantom. The spatial resolution of the two settings were estimated by reconstructing a 0.15‐mm wire phantom and comparing its full width half maximum (FWHM). A CBCT scan of a rodent head was also acquired to further demonstrate the improved resolution using the x‐ray lens. Result: The proposed imaging setup with x‐ray lens had a limited exposure area of 5 cm by 5 cm on the detector, which was suitable for guiding radio‐neuromodulation to a small target in rodent brain. Compared to conventional imaging acquisition with a measured x‐ray focal spot of 0.395 mm FWHM, the virtual focal spot size was measured at 0.175 mm. The reduction in focal spot size with lens leads to an almost doubled planar imaging resolution and a 26% enhancement in 3D spatial resolution. A realistic CBCT acquisition of a rodent head mimicked the imaging acquisition step for radio‐neuromodulation and further showed the improved visualization for fine structures. Conclusion: This work demonstrated that the focused kV x‐ray technique was capable of generating small focal spot size of &lt;0.2 mm, which substantially improved x‐ray imaging resolution for small animal imaging. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: &lt;i&gt;Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder&#39;s express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.&lt;/i&gt; (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=164875861
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1002/mp.16413
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 7
        StartPage: 4459
    Subjects:
      – SubjectFull: High resolution imaging
        Type: general
      – SubjectFull: X-rays
        Type: general
      – SubjectFull: Cone beam computed tomography
        Type: general
      – SubjectFull: X-ray scattering
        Type: general
      – SubjectFull: Small-angle X-ray scattering
        Type: general
      – SubjectFull: X-ray imaging
        Type: general
    Titles:
      – TitleFull: High resolution imaging with focused kV x‐rays for small animal radio‐neuromodulation.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Shi, Linxi
      – PersonEntity:
          Name:
            NameFull: Bennett, N. Robert
      – PersonEntity:
          Name:
            NameFull: Nguyen, Eric
      – PersonEntity:
          Name:
            NameFull: MacDonald, Carolyn
      – PersonEntity:
          Name:
            NameFull: Wang, Adam
      – PersonEntity:
          Name:
            NameFull: Liu, Wu
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 07
              Text: Jul2023
              Type: published
              Y: 2023
          Identifiers:
            – Type: issn-print
              Value: 00942405
          Numbering:
            – Type: volume
              Value: 50
            – Type: issue
              Value: 7
          Titles:
            – TitleFull: Medical Physics
              Type: main
ResultId 1