Robot-assisted biopsy using ultrasound guidance: initial results from in vitro tests.

Saved in:
Bibliographic Details
Title: Robot-assisted biopsy using ultrasound guidance: initial results from in vitro tests.
Authors: Kettenbach, Joachim1 joachim.kettenbach@univie.ac.at, Kronreif, Gernot2, Figl, Michael3, Fürst, Martin2, Birkfellner, Wolfgang3, Hanel, Rudolf3, Bergmann, Helmar3, Fürst, Martin (AUTHOR)
Source: European Radiology. Apr2005, Vol. 15 Issue 4, p765-771. 7p.
Subjects: Biopsy, Diagnostic specimens, Interventional radiology, Operative ultrasonography, Ultrasonics in surgery, Diagnostic ultrasonic imaging, Comparative studies, Research methodology, Medical cooperation, Research, Research evaluation, Robotics, Ultrasonic imaging, Pilot projects, Product design, Evaluation research, Equipment & supplies
Abstract: The purpose of this study was to develop a robotic system for ultrasound (US)-guided biopsy and to validate the feasibility, accuracy and efficacy using phantom tests. Twenty peas (mean diameter 9.3+/-0.1 mm) embedded within a gel-phantom were selected for biopsy. Once the best access was defined, the position of the US transducer was recorded by an optical tracking system. Positional data of the transducer and the corresponding US image were transferred to the roboter planning system (LINUX-based industrial PC equipped with video capture card). Once the appropriate position, angulation and pitch were calculated, the robotic arm moved automatically with seven degrees-of-freedom to the planned insertion path, aiming the needle-positioning unit at the center of the target. Then, the biopsy was performed manually using a coaxial technique. The length of all harvested specimens was measured, and the deviation of the actual needle tract from the center of the target was evaluated sonographically. In all targets, the biopsy specimen (mean length 5+/-1.2 mm) was harvested with only one needle pass required The mean deviation of the needle tip from the center of the target was 1.1+/-0.8 mm. Robotic assisted biopsies in-vitro using US-guidance were feasible and provided high accuracy. [ABSTRACT FROM AUTHOR]
Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Links:
  – Type: pdflink
Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 16580621
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Robot-assisted biopsy using ultrasound guidance: initial results from in vitro tests.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Kettenbach%2C+Joachim%22">Kettenbach, Joachim</searchLink><relatesTo>1</relatesTo><i> joachim.kettenbach@univie.ac.at</i><br /><searchLink fieldCode="AR" term="%22Kronreif%2C+Gernot%22">Kronreif, Gernot</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Figl%2C+Michael%22">Figl, Michael</searchLink><relatesTo>3</relatesTo><br /><searchLink fieldCode="AR" term="%22Fürst%2C+Martin%22">Fürst, Martin</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Birkfellner%2C+Wolfgang%22">Birkfellner, Wolfgang</searchLink><relatesTo>3</relatesTo><br /><searchLink fieldCode="AR" term="%22Hanel%2C+Rudolf%22">Hanel, Rudolf</searchLink><relatesTo>3</relatesTo><br /><searchLink fieldCode="AR" term="%22Bergmann%2C+Helmar%22">Bergmann, Helmar</searchLink><relatesTo>3</relatesTo><br /><searchLink fieldCode="AR" term="%22Fürst%2C+Martin%22">Fürst, Martin</searchLink> (AUTHOR)
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22European+Radiology%22">European Radiology</searchLink>. Apr2005, Vol. 15 Issue 4, p765-771. 7p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Biopsy%22">Biopsy</searchLink><br /><searchLink fieldCode="DE" term="%22Diagnostic+specimens%22">Diagnostic specimens</searchLink><br /><searchLink fieldCode="DE" term="%22Interventional+radiology%22">Interventional radiology</searchLink><br /><searchLink fieldCode="DE" term="%22Operative+ultrasonography%22">Operative ultrasonography</searchLink><br /><searchLink fieldCode="DE" term="%22Ultrasonics+in+surgery%22">Ultrasonics in surgery</searchLink><br /><searchLink fieldCode="DE" term="%22Diagnostic+ultrasonic+imaging%22">Diagnostic ultrasonic imaging</searchLink><br /><searchLink fieldCode="DE" term="%22Comparative+studies%22">Comparative studies</searchLink><br /><searchLink fieldCode="DE" term="%22Research+methodology%22">Research methodology</searchLink><br /><searchLink fieldCode="DE" term="%22Medical+cooperation%22">Medical cooperation</searchLink><br /><searchLink fieldCode="DE" term="%22Research%22">Research</searchLink><br /><searchLink fieldCode="DE" term="%22Research+evaluation%22">Research evaluation</searchLink><br /><searchLink fieldCode="DE" term="%22Robotics%22">Robotics</searchLink><br /><searchLink fieldCode="DE" term="%22Ultrasonic+imaging%22">Ultrasonic imaging</searchLink><br /><searchLink fieldCode="DE" term="%22Pilot+projects%22">Pilot projects</searchLink><br /><searchLink fieldCode="DE" term="%22Product+design%22">Product design</searchLink><br /><searchLink fieldCode="DE" term="%22Evaluation+research%22">Evaluation research</searchLink><br /><searchLink fieldCode="DE" term="%22Equipment+%26+supplies%22">Equipment & supplies</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: The purpose of this study was to develop a robotic system for ultrasound (US)-guided biopsy and to validate the feasibility, accuracy and efficacy using phantom tests. Twenty peas (mean diameter 9.3+/-0.1 mm) embedded within a gel-phantom were selected for biopsy. Once the best access was defined, the position of the US transducer was recorded by an optical tracking system. Positional data of the transducer and the corresponding US image were transferred to the roboter planning system (LINUX-based industrial PC equipped with video capture card). Once the appropriate position, angulation and pitch were calculated, the robotic arm moved automatically with seven degrees-of-freedom to the planned insertion path, aiming the needle-positioning unit at the center of the target. Then, the biopsy was performed manually using a coaxial technique. The length of all harvested specimens was measured, and the deviation of the actual needle tract from the center of the target was evaluated sonographically. In all targets, the biopsy specimen (mean length 5+/-1.2 mm) was harvested with only one needle pass required The mean deviation of the needle tip from the center of the target was 1.1+/-0.8 mm. Robotic assisted biopsies in-vitro using US-guidance were feasible and provided high accuracy. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=16580621
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1007/s00330-004-2487-x
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 7
        StartPage: 765
    Subjects:
      – SubjectFull: Biopsy
        Type: general
      – SubjectFull: Diagnostic specimens
        Type: general
      – SubjectFull: Interventional radiology
        Type: general
      – SubjectFull: Operative ultrasonography
        Type: general
      – SubjectFull: Ultrasonics in surgery
        Type: general
      – SubjectFull: Diagnostic ultrasonic imaging
        Type: general
      – SubjectFull: Comparative studies
        Type: general
      – SubjectFull: Research methodology
        Type: general
      – SubjectFull: Medical cooperation
        Type: general
      – SubjectFull: Research
        Type: general
      – SubjectFull: Research evaluation
        Type: general
      – SubjectFull: Robotics
        Type: general
      – SubjectFull: Ultrasonic imaging
        Type: general
      – SubjectFull: Pilot projects
        Type: general
      – SubjectFull: Product design
        Type: general
      – SubjectFull: Evaluation research
        Type: general
      – SubjectFull: Equipment & supplies
        Type: general
    Titles:
      – TitleFull: Robot-assisted biopsy using ultrasound guidance: initial results from in vitro tests.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Kettenbach, Joachim
      – PersonEntity:
          Name:
            NameFull: Kronreif, Gernot
      – PersonEntity:
          Name:
            NameFull: Figl, Michael
      – PersonEntity:
          Name:
            NameFull: Fürst, Martin
      – PersonEntity:
          Name:
            NameFull: Birkfellner, Wolfgang
      – PersonEntity:
          Name:
            NameFull: Hanel, Rudolf
      – PersonEntity:
          Name:
            NameFull: Bergmann, Helmar
      – PersonEntity:
          Name:
            NameFull: Fürst, Martin
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 04
              Text: Apr2005
              Type: published
              Y: 2005
          Identifiers:
            – Type: issn-print
              Value: 09387994
          Numbering:
            – Type: volume
              Value: 15
            – Type: issue
              Value: 4
          Titles:
            – TitleFull: European Radiology
              Type: main
ResultId 1