Prospective comparison of MR enteroclysis with multidetector spiral-CT enteroclysis: interobserver agreement and sensitivity by means of "sign-by-sign" correlation.
Saved in:
| Title: | Prospective comparison of MR enteroclysis with multidetector spiral-CT enteroclysis: interobserver agreement and sensitivity by means of "sign-by-sign" correlation. |
|---|---|
| Authors: | Schmidt, Sabine1 sabine.schmidt@chuv.hospvd.ch, Lepori, Domenico1, Meuwly, Jean-Yves1, Duvoisin, Bertrand1, Meuli, Reto1, Michetti, Pierre2, Felley, Christian2, Schnyder, Pierre1, van Melle, Guy3, Denys, Alban1 |
| Source: | European Radiology. Jun2003, Vol. 13 Issue 6, p1303-1311. 9p. |
| Subjects: | Enteroclysis, Small intestine radiography, Intestinal diseases, Diagnostic imaging, Medical radiography |
| Abstract: | Our objective was a prospective comparison of MR enteroclysis (MRE) with multidetector spiral-CT enteroclysis (MSCTE). Fifty patients with various suspected small bowel diseases were investigated by MSCTE and MRE. The MSCTE was performed using slices of 2.5 mm, immediately followed by MRE, obtaining T1- and T2-weighted sequences, including gadolinium-enhanced acquisition with fat saturation. Three radiologists independently evaluated MSCTE and MRE searching for 12 pathological signs. Interobserver agreement was calculated. Sensitivities and specificities resulted from comparison with pathological results ( n=29) and patient's clinical evolution ( n=21). Most pathological signs, such as bowel wall thickening (BWT), bowel wall enhancement (BWE) and lymphadenopathy (ADP), showed better interobserver agreement on MSCTE than on MRE (BWT: 0.65 vs 0.48; BWE: 0.51 vs 0.37; ADP: 0.52 vs 0.15). Sensitivity of MSCTE was higher than that of MRE in detecting BWT (88.9 vs 60%), BWE (78.6 vs 55.5%) and ADP (63.8 vs 14.3%). Wilcoxon signed-rank test revealed significantly better sensitivity of MSCTE than that of MRE for each observer ( p=0.028, p=0.046, p=0.028, respectively). Taking the given study design into account, MSCTE provides better sensitivity in detecting lesions of the small bowel than MRE, with higher interobserver agreement. [ABSTRACT FROM AUTHOR] |
| Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
| FullText | Links: – Type: pdflink Text: Availability: 0 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 16654571 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Prospective comparison of MR enteroclysis with multidetector spiral-CT enteroclysis: interobserver agreement and sensitivity by means of "sign-by-sign" correlation. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Schmidt%2C+Sabine%22">Schmidt, Sabine</searchLink><relatesTo>1</relatesTo><i> sabine.schmidt@chuv.hospvd.ch</i><br /><searchLink fieldCode="AR" term="%22Lepori%2C+Domenico%22">Lepori, Domenico</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Meuwly%2C+Jean-Yves%22">Meuwly, Jean-Yves</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Duvoisin%2C+Bertrand%22">Duvoisin, Bertrand</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Meuli%2C+Reto%22">Meuli, Reto</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Michetti%2C+Pierre%22">Michetti, Pierre</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Felley%2C+Christian%22">Felley, Christian</searchLink><relatesTo>2</relatesTo><br /><searchLink fieldCode="AR" term="%22Schnyder%2C+Pierre%22">Schnyder, Pierre</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22van+Melle%2C+Guy%22">van Melle, Guy</searchLink><relatesTo>3</relatesTo><br /><searchLink fieldCode="AR" term="%22Denys%2C+Alban%22">Denys, Alban</searchLink><relatesTo>1</relatesTo> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22European+Radiology%22">European Radiology</searchLink>. Jun2003, Vol. 13 Issue 6, p1303-1311. 9p. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22Enteroclysis%22">Enteroclysis</searchLink><br /><searchLink fieldCode="DE" term="%22Small+intestine+radiography%22">Small intestine radiography</searchLink><br /><searchLink fieldCode="DE" term="%22Intestinal+diseases%22">Intestinal diseases</searchLink><br /><searchLink fieldCode="DE" term="%22Diagnostic+imaging%22">Diagnostic imaging</searchLink><br /><searchLink fieldCode="DE" term="%22Medical+radiography%22">Medical radiography</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: Our objective was a prospective comparison of MR enteroclysis (MRE) with multidetector spiral-CT enteroclysis (MSCTE). Fifty patients with various suspected small bowel diseases were investigated by MSCTE and MRE. The MSCTE was performed using slices of 2.5 mm, immediately followed by MRE, obtaining T1- and T2-weighted sequences, including gadolinium-enhanced acquisition with fat saturation. Three radiologists independently evaluated MSCTE and MRE searching for 12 pathological signs. Interobserver agreement was calculated. Sensitivities and specificities resulted from comparison with pathological results ( n=29) and patient's clinical evolution ( n=21). Most pathological signs, such as bowel wall thickening (BWT), bowel wall enhancement (BWE) and lymphadenopathy (ADP), showed better interobserver agreement on MSCTE than on MRE (BWT: 0.65 vs 0.48; BWE: 0.51 vs 0.37; ADP: 0.52 vs 0.15). Sensitivity of MSCTE was higher than that of MRE in detecting BWT (88.9 vs 60%), BWE (78.6 vs 55.5%) and ADP (63.8 vs 14.3%). Wilcoxon signed-rank test revealed significantly better sensitivity of MSCTE than that of MRE for each observer ( p=0.028, p=0.046, p=0.028, respectively). Taking the given study design into account, MSCTE provides better sensitivity in detecting lesions of the small bowel than MRE, with higher interobserver agreement. [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=16654571 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1007/s00330-002-1710-x Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 9 StartPage: 1303 Subjects: – SubjectFull: Enteroclysis Type: general – SubjectFull: Small intestine radiography Type: general – SubjectFull: Intestinal diseases Type: general – SubjectFull: Diagnostic imaging Type: general – SubjectFull: Medical radiography Type: general Titles: – TitleFull: Prospective comparison of MR enteroclysis with multidetector spiral-CT enteroclysis: interobserver agreement and sensitivity by means of "sign-by-sign" correlation. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Schmidt, Sabine – PersonEntity: Name: NameFull: Lepori, Domenico – PersonEntity: Name: NameFull: Meuwly, Jean-Yves – PersonEntity: Name: NameFull: Duvoisin, Bertrand – PersonEntity: Name: NameFull: Meuli, Reto – PersonEntity: Name: NameFull: Michetti, Pierre – PersonEntity: Name: NameFull: Felley, Christian – PersonEntity: Name: NameFull: Schnyder, Pierre – PersonEntity: Name: NameFull: van Melle, Guy – PersonEntity: Name: NameFull: Denys, Alban IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 06 Text: Jun2003 Type: published Y: 2003 Identifiers: – Type: issn-print Value: 09387994 Numbering: – Type: volume Value: 13 – Type: issue Value: 6 Titles: – TitleFull: European Radiology Type: main |
| ResultId | 1 |