A novel near‐infrared fluorescent and colorimetric probe for selective detection of Ag+ and Hg2+.
Saved in:
| Title: | A novel near‐infrared fluorescent and colorimetric probe for selective detection of Ag+ and Hg2+. |
|---|---|
| Authors: | Min, Yuquan1 (AUTHOR), Han, Xin2 (AUTHOR) sssshanxin@gmail.com, Qi, Youguo1 (AUTHOR), Jiang, Lin1 (AUTHOR), Song, Yanxi3 (AUTHOR), Ma, Yilin1 (AUTHOR), Zhang, Jian1 (AUTHOR), Li, Hongqi1 (AUTHOR) hongqili@dhu.edu.cn |
| Source: | Coloration Technology. Feb2024, Vol. 140 Issue 1, p30-41. 12p. |
| Subjects: | Intramolecular proton transfer reactions, Fluorescent probes, Proton magnetic resonance, Intramolecular charge transfer, Silver ions, High performance liquid chromatography, Silver, Mercury (Element) |
| Abstract: | It is particularly important to develop effective and specific detection methods for harmful metal ions such as the silver ion (Ag+) and mercury ion (Hg2+). In this article, a new near‐infrared (NIR) fluorescent probe (N‐FP) based on intramolecular charge transfer (ICT) effect was designed and synthesised, which exhibited the characteristics of large Stokes shift (163 nm) and excellent stability. Addition of Ag+ or Hg2+ to the N‐FP solution in ethanol/water (9:1, v/v) caused remarkable enhancement of fluorescence emission at 661 nm, bathochromic shift of ultraviolet‐visible absorption wavelength, and colour change from orange to red or purple. While adding other metal ions including Li+, Na+, K+, Ag+, Cu2+, Fe2+, Zn2+, Co2+, Ni2+, Mn2+, Sr2+, Ca2+, Mg2+, Al3+, Cr3+ and Fe3+ did not bring about substantial spectral and colour change. The detection limit of the N‐FP for Ag+ and Hg2+ was calculated to be 1.1 and 0.72 μM, respectively. The N‐FP could be used to recognise Ag+ and Hg2+ in a wide pH range of 1–10. The sensing mechanism was proposed and demonstrated by proton nuclear magnetic resonance (1H‐NMR), high‐performance liquid chromatography (HPLC) and mass spectrometry (MS) measurements [ABSTRACT FROM AUTHOR] |
| Copyright of Coloration Technology is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
|
Full text is not displayed to guests.
Login for full access.
|
|
| Abstract: | It is particularly important to develop effective and specific detection methods for harmful metal ions such as the silver ion (Ag+) and mercury ion (Hg2+). In this article, a new near‐infrared (NIR) fluorescent probe (N‐FP) based on intramolecular charge transfer (ICT) effect was designed and synthesised, which exhibited the characteristics of large Stokes shift (163 nm) and excellent stability. Addition of Ag+ or Hg2+ to the N‐FP solution in ethanol/water (9:1, v/v) caused remarkable enhancement of fluorescence emission at 661 nm, bathochromic shift of ultraviolet‐visible absorption wavelength, and colour change from orange to red or purple. While adding other metal ions including Li+, Na+, K+, Ag+, Cu2+, Fe2+, Zn2+, Co2+, Ni2+, Mn2+, Sr2+, Ca2+, Mg2+, Al3+, Cr3+ and Fe3+ did not bring about substantial spectral and colour change. The detection limit of the N‐FP for Ag+ and Hg2+ was calculated to be 1.1 and 0.72 μM, respectively. The N‐FP could be used to recognise Ag+ and Hg2+ in a wide pH range of 1–10. The sensing mechanism was proposed and demonstrated by proton nuclear magnetic resonance (1H‐NMR), high‐performance liquid chromatography (HPLC) and mass spectrometry (MS) measurements [ABSTRACT FROM AUTHOR] |
|---|---|
| ISSN: | 14723581 |
| DOI: | 10.1111/cote.12687 |