Wear metal determination in lubricating oils by reversed-phase dispersive liquid–liquid microextraction and microwave induced plasma optical emission spectrometry.

Saved in:
Bibliographic Details
Title: Wear metal determination in lubricating oils by reversed-phase dispersive liquid–liquid microextraction and microwave induced plasma optical emission spectrometry.
Authors: Sáez, Carmen1,2 (AUTHOR), Stoitsov, Dimitar3 (AUTHOR), Aguirre, Miguel Ángel2 (AUTHOR) aguirre.pastor@ua.es, Kmetov, Veselin3 (AUTHOR), Coscollà, Clara4 (AUTHOR), Canals, Antonio2 (AUTHOR) a.canals@ua.es
Source: JAAS (Journal of Analytical Atomic Spectrometry). Feb2024, Vol. 39 Issue 2, p370-377. 8p.
Subjects: Inductively coupled plasma atomic emission spectrometry, Microwave plasmas, Lubricating oils, Analytical chemistry, Diesel motors, Ochratoxins
Abstract: A periodic study of engine oil can allow one to anticipate possible breakdowns that a vehicle could have. Due to the complexity of the matrix of this type of sample, a sample treatment prior to analysis is necessary. Analytical chemistry is constantly searching for simpler, more sensitive and environmentally friendly methods. The reversed phase dispersive liquid–liquid microextraction fulfills all the characteristics for the analysis in this type of sample by microwave induced plasma optical emission spectrometry (MIP OES). In this work, the extractant solvent used for the microextraction procedure is a diluted acid solution (i.e., 3 M HCl), which is a less-hazardous solvent, in comparison with other solvents used in microextraction procedures. Besides, it is perfectly compatible with MIP OES. The main experimental factors affecting the extraction of Cr, Cu, Mn, Mo, and Ni (i.e., amount of sample, extractant type, acid concentration, extractant volume, extractant time, and centrifugation time and speed) are optimized using a multivariate analysis consisting of two steps: a Plackett–Burman design followed by a circumscribed central composite design. Under optimum conditions (i.e., amount of sample: 5.9 g; extractant volume: 60 μL; extractant type: HCl; acid concentration: 3 M; extraction time: 3 min; centrifugation time: 3 min; centrifugation speed: 2000 rpm), the proposed analytical method is validated and employed to analyze different samples (i.e., used and unused engine oils). Two calibration methods have been evaluated since matrix effects have been observed in the used engine oil sample. These effects have been eliminated using standard addition calibration obtaining RSD and recovery values in the range of 4–12% and 94–106%, respectively, for samples spiked with 1 μg g−1 of Cr, Cu, Mn, Mo and Ni. Finally, the greenness of this method has been assessed by the Eco-Scale metrics. [ABSTRACT FROM AUTHOR]
Copyright of JAAS (Journal of Analytical Atomic Spectrometry) is the property of Royal Society of Chemistry and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 175307904
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Wear metal determination in lubricating oils by reversed-phase dispersive liquid–liquid microextraction and microwave induced plasma optical emission spectrometry.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Sáez%2C+Carmen%22">Sáez, Carmen</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Stoitsov%2C+Dimitar%22">Stoitsov, Dimitar</searchLink><relatesTo>3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Aguirre%2C+Miguel+Ángel%22">Aguirre, Miguel Ángel</searchLink><relatesTo>2</relatesTo> (AUTHOR)<i> aguirre.pastor@ua.es</i><br /><searchLink fieldCode="AR" term="%22Kmetov%2C+Veselin%22">Kmetov, Veselin</searchLink><relatesTo>3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Coscollà%2C+Clara%22">Coscollà, Clara</searchLink><relatesTo>4</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Canals%2C+Antonio%22">Canals, Antonio</searchLink><relatesTo>2</relatesTo> (AUTHOR)<i> a.canals@ua.es</i>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22JAAS+%28Journal+of+Analytical+Atomic+Spectrometry%29%22">JAAS (Journal of Analytical Atomic Spectrometry)</searchLink>. Feb2024, Vol. 39 Issue 2, p370-377. 8p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Inductively+coupled+plasma+atomic+emission+spectrometry%22">Inductively coupled plasma atomic emission spectrometry</searchLink><br /><searchLink fieldCode="DE" term="%22Microwave+plasmas%22">Microwave plasmas</searchLink><br /><searchLink fieldCode="DE" term="%22Lubricating+oils%22">Lubricating oils</searchLink><br /><searchLink fieldCode="DE" term="%22Analytical+chemistry%22">Analytical chemistry</searchLink><br /><searchLink fieldCode="DE" term="%22Diesel+motors%22">Diesel motors</searchLink><br /><searchLink fieldCode="DE" term="%22Ochratoxins%22">Ochratoxins</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: A periodic study of engine oil can allow one to anticipate possible breakdowns that a vehicle could have. Due to the complexity of the matrix of this type of sample, a sample treatment prior to analysis is necessary. Analytical chemistry is constantly searching for simpler, more sensitive and environmentally friendly methods. The reversed phase dispersive liquid–liquid microextraction fulfills all the characteristics for the analysis in this type of sample by microwave induced plasma optical emission spectrometry (MIP OES). In this work, the extractant solvent used for the microextraction procedure is a diluted acid solution (i.e., 3 M HCl), which is a less-hazardous solvent, in comparison with other solvents used in microextraction procedures. Besides, it is perfectly compatible with MIP OES. The main experimental factors affecting the extraction of Cr, Cu, Mn, Mo, and Ni (i.e., amount of sample, extractant type, acid concentration, extractant volume, extractant time, and centrifugation time and speed) are optimized using a multivariate analysis consisting of two steps: a Plackett–Burman design followed by a circumscribed central composite design. Under optimum conditions (i.e., amount of sample: 5.9 g; extractant volume: 60 μL; extractant type: HCl; acid concentration: 3 M; extraction time: 3 min; centrifugation time: 3 min; centrifugation speed: 2000 rpm), the proposed analytical method is validated and employed to analyze different samples (i.e., used and unused engine oils). Two calibration methods have been evaluated since matrix effects have been observed in the used engine oil sample. These effects have been eliminated using standard addition calibration obtaining RSD and recovery values in the range of 4–12% and 94–106%, respectively, for samples spiked with 1 μg g−1 of Cr, Cu, Mn, Mo and Ni. Finally, the greenness of this method has been assessed by the Eco-Scale metrics. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of JAAS (Journal of Analytical Atomic Spectrometry) is the property of Royal Society of Chemistry and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=175307904
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1039/d3ja00319a
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 8
        StartPage: 370
    Subjects:
      – SubjectFull: Inductively coupled plasma atomic emission spectrometry
        Type: general
      – SubjectFull: Microwave plasmas
        Type: general
      – SubjectFull: Lubricating oils
        Type: general
      – SubjectFull: Analytical chemistry
        Type: general
      – SubjectFull: Diesel motors
        Type: general
      – SubjectFull: Ochratoxins
        Type: general
    Titles:
      – TitleFull: Wear metal determination in lubricating oils by reversed-phase dispersive liquid–liquid microextraction and microwave induced plasma optical emission spectrometry.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Sáez, Carmen
      – PersonEntity:
          Name:
            NameFull: Stoitsov, Dimitar
      – PersonEntity:
          Name:
            NameFull: Aguirre, Miguel Ángel
      – PersonEntity:
          Name:
            NameFull: Kmetov, Veselin
      – PersonEntity:
          Name:
            NameFull: Coscollà, Clara
      – PersonEntity:
          Name:
            NameFull: Canals, Antonio
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 02
              Text: Feb2024
              Type: published
              Y: 2024
          Identifiers:
            – Type: issn-print
              Value: 02679477
          Numbering:
            – Type: volume
              Value: 39
            – Type: issue
              Value: 2
          Titles:
            – TitleFull: JAAS (Journal of Analytical Atomic Spectrometry)
              Type: main
ResultId 1