Content addressable memory (CAM) based robust anonymous authentication and integrity preservation scheme for wireless body area networks (WBAN).
Saved in:
| Title: | Content addressable memory (CAM) based robust anonymous authentication and integrity preservation scheme for wireless body area networks (WBAN). |
|---|---|
| Authors: | Rajasekaran, Arun Sekar1 (AUTHOR), Azees, M.2 (AUTHOR), Dash, Chandra Sekhar3 (AUTHOR), Nayyar, Anand4 (AUTHOR) anandnayyar@duytan.edu.vn |
| Source: | Multimedia Tools & Applications. Feb2024, Vol. 83 Issue 7, p20429-20455. 27p. |
| Subjects: | Verilog (Computer hardware description language), Elliptic curve cryptography, Artificial implants, Software development tools, Body area networks |
| Abstract: | Health plays a foremost role for every individual. To preserve the health, continuous monitoring of health is essential. Wireless Body Area Network (WBAN) is a type of wireless network used to monitor the health and fitness-related parameters of the human body. It is a short-range wireless network that connects wearable and implanted devices to each other and to a centralized server for data collection and analysis. As the advancement in the medical field increases, the security threats to health-related medical data also increases. The medical data of each individual (patient) is highly confidential. So, the privacy and security of this confidential information are of prior importance. Though several schemes have been proposed in the previous years, the anonymity and integrity preservation with lightweight is not addressed effectively. The proposed idea is to develop an anonymous integrity-preserved authenticated lightweight scheme based on Elliptic curve cryptography (ECC). The performance investigation of this scheme proves to be more efficient in terms of computational cost i.e., only 3.8 ms (27.53% less) is required for performing the authentication. Moreover, communicational cost at the doctor's side requires 960 bits (41.17% less) when compared to related schemes. In addition, the suggested scheme can serve up to a maximum of 6250 users in one minute. The analysis is simulated using the Cygwin software tool and its reports are analysed and proved to be noteworthy. Further, a health monitoring system is designed using Verilog Hardware description language (HDL). Finally, hardware implementation is done in - EDGE ZYNQ 7000 SoC FPGA Development board and synthesized using the Cadence tool using CMOS GPDK 90 nm technology. [ABSTRACT FROM AUTHOR] |
| Copyright of Multimedia Tools & Applications is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
|
Full text is not displayed to guests.
Login for full access.
|
|
| Abstract: | Health plays a foremost role for every individual. To preserve the health, continuous monitoring of health is essential. Wireless Body Area Network (WBAN) is a type of wireless network used to monitor the health and fitness-related parameters of the human body. It is a short-range wireless network that connects wearable and implanted devices to each other and to a centralized server for data collection and analysis. As the advancement in the medical field increases, the security threats to health-related medical data also increases. The medical data of each individual (patient) is highly confidential. So, the privacy and security of this confidential information are of prior importance. Though several schemes have been proposed in the previous years, the anonymity and integrity preservation with lightweight is not addressed effectively. The proposed idea is to develop an anonymous integrity-preserved authenticated lightweight scheme based on Elliptic curve cryptography (ECC). The performance investigation of this scheme proves to be more efficient in terms of computational cost i.e., only 3.8 ms (27.53% less) is required for performing the authentication. Moreover, communicational cost at the doctor's side requires 960 bits (41.17% less) when compared to related schemes. In addition, the suggested scheme can serve up to a maximum of 6250 users in one minute. The analysis is simulated using the Cygwin software tool and its reports are analysed and proved to be noteworthy. Further, a health monitoring system is designed using Verilog Hardware description language (HDL). Finally, hardware implementation is done in - EDGE ZYNQ 7000 SoC FPGA Development board and synthesized using the Cadence tool using CMOS GPDK 90 nm technology. [ABSTRACT FROM AUTHOR] |
|---|---|
| ISSN: | 13807501 |
| DOI: | 10.1007/s11042-023-16257-1 |