AAPM WGVRTO report 390: A survey of veterinary radiation oncology equipment and infrastructure in 2022.

Saved in:
Bibliographic Details
Title: AAPM WGVRTO report 390: A survey of veterinary radiation oncology equipment and infrastructure in 2022.
Authors: Basran, Parminder S.1 (AUTHOR) psb92@cornell.edu, Turek, Michelle2 (AUTHOR), Selting, Kimberly A.3 (AUTHOR), Rancilio, Nicholas4 (AUTHOR)
Source: Medical Physics. Jun2024, Vol. 51 Issue 6, p3924-3931. 8p.
Subjects: Image reconstruction algorithms, Cone beam computed tomography, Image-guided radiation therapy, Medical physics, Radiation, Oncology
Abstract: Since 2010, there has been little published data on the state of equipment and infrastructure in veterinary radiation oncology clinical practice. These data are important not only to identify the status and use of technology within the veterinary radiation oncology community but also to help identify the extent of medical physics support. The purpose of our study is to report findings from a survey of veterinary radiation oncologists in the USA, Canada, and select centers outside of North America in 2022. A 40‐question survey covering topics such as type of radiotherapy equipment, techniques offered, treatment planning systems and dose calculation algorithms, special techniques, board‐certified radiation oncologists and residents, and extent of medical physics support was distributed through an online survey tool. Results from 40 veterinary radiation oncology institutions, with equipment explicitly used for veterinary care, suggest that the current state of practice is not dissimilar to what currently exists in human radiation oncology facilities; techniques and technologies commonly employed include flattening filter‐free mode megavoltage beams, volumetric arc therapy, daily cone‐beam computed tomography, image‐guided radiation therapy, and sophisticated dose calculation algorithms. These findings suggest the need for modern radiation oncology acceptance testing, commissioning, and quality assurance programs within the veterinary community. The increase in veterinary radiation oncology residency positions and increasing sophistication of equipment suggests that increased levels of standardized medical physics support would benefit the veterinary radiation oncology community. [ABSTRACT FROM AUTHOR]
Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Full text is not displayed to guests.
FullText Links:
  – Type: pdflink
Text:
  Availability: 1
Header DbId: egs
DbLabel: Engineering Source
An: 177626353
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: AAPM WGVRTO report 390: A survey of veterinary radiation oncology equipment and infrastructure in 2022.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Basran%2C+Parminder+S%2E%22">Basran, Parminder S.</searchLink><relatesTo>1</relatesTo> (AUTHOR)<i> psb92@cornell.edu</i><br /><searchLink fieldCode="AR" term="%22Turek%2C+Michelle%22">Turek, Michelle</searchLink><relatesTo>2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Selting%2C+Kimberly+A%2E%22">Selting, Kimberly A.</searchLink><relatesTo>3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Rancilio%2C+Nicholas%22">Rancilio, Nicholas</searchLink><relatesTo>4</relatesTo> (AUTHOR)
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Medical+Physics%22">Medical Physics</searchLink>. Jun2024, Vol. 51 Issue 6, p3924-3931. 8p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Image+reconstruction+algorithms%22">Image reconstruction algorithms</searchLink><br /><searchLink fieldCode="DE" term="%22Cone+beam+computed+tomography%22">Cone beam computed tomography</searchLink><br /><searchLink fieldCode="DE" term="%22Image-guided+radiation+therapy%22">Image-guided radiation therapy</searchLink><br /><searchLink fieldCode="DE" term="%22Medical+physics%22">Medical physics</searchLink><br /><searchLink fieldCode="DE" term="%22Radiation%22">Radiation</searchLink><br /><searchLink fieldCode="DE" term="%22Oncology%22">Oncology</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Since 2010, there has been little published data on the state of equipment and infrastructure in veterinary radiation oncology clinical practice. These data are important not only to identify the status and use of technology within the veterinary radiation oncology community but also to help identify the extent of medical physics support. The purpose of our study is to report findings from a survey of veterinary radiation oncologists in the USA, Canada, and select centers outside of North America in 2022. A 40‐question survey covering topics such as type of radiotherapy equipment, techniques offered, treatment planning systems and dose calculation algorithms, special techniques, board‐certified radiation oncologists and residents, and extent of medical physics support was distributed through an online survey tool. Results from 40 veterinary radiation oncology institutions, with equipment explicitly used for veterinary care, suggest that the current state of practice is not dissimilar to what currently exists in human radiation oncology facilities; techniques and technologies commonly employed include flattening filter‐free mode megavoltage beams, volumetric arc therapy, daily cone‐beam computed tomography, image‐guided radiation therapy, and sophisticated dose calculation algorithms. These findings suggest the need for modern radiation oncology acceptance testing, commissioning, and quality assurance programs within the veterinary community. The increase in veterinary radiation oncology residency positions and increasing sophistication of equipment suggests that increased levels of standardized medical physics support would benefit the veterinary radiation oncology community. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=177626353
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1002/mp.17042
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 8
        StartPage: 3924
    Subjects:
      – SubjectFull: Image reconstruction algorithms
        Type: general
      – SubjectFull: Cone beam computed tomography
        Type: general
      – SubjectFull: Image-guided radiation therapy
        Type: general
      – SubjectFull: Medical physics
        Type: general
      – SubjectFull: Radiation
        Type: general
      – SubjectFull: Oncology
        Type: general
    Titles:
      – TitleFull: AAPM WGVRTO report 390: A survey of veterinary radiation oncology equipment and infrastructure in 2022.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Basran, Parminder S.
      – PersonEntity:
          Name:
            NameFull: Turek, Michelle
      – PersonEntity:
          Name:
            NameFull: Selting, Kimberly A.
      – PersonEntity:
          Name:
            NameFull: Rancilio, Nicholas
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 06
              Text: Jun2024
              Type: published
              Y: 2024
          Identifiers:
            – Type: issn-print
              Value: 00942405
          Numbering:
            – Type: volume
              Value: 51
            – Type: issue
              Value: 6
          Titles:
            – TitleFull: Medical Physics
              Type: main
ResultId 1