Cyclotron and linear accelerator generated scanning proton beams for lung cancer SBRT: Interplay effects and mitigations.

Saved in:
Bibliographic Details
Title: Cyclotron and linear accelerator generated scanning proton beams for lung cancer SBRT: Interplay effects and mitigations.
Authors: Liu, Chieh‐Wen1 (AUTHOR), Kolano, Anna M.2,3 (AUTHOR), Gray, Tara1 (AUTHOR), Stephans, Kevin L.1 (AUTHOR), Videtic, Gregory M. M.1 (AUTHOR), Farr, Jonathan B.2,3 (AUTHOR) jonathan.farr@avo-adam.com, Xia, Ping1 (AUTHOR) xiap@ccf.org
Source: Medical Physics. Jun2024, Vol. 51 Issue 6, p3985-3994. 10p.
Subjects: Proton accelerators, Stereotactic radiotherapy, Lung cancer, Cyclotrons, Proton beams, Linear accelerators, Non-small-cell lung carcinoma
Abstract: Background: Pencil beam scanning (PBS) proton therapy for moving targets is known to be impacted by interplay effects between the scanning beam and organ motion. While respiratory motion in the thoracic region is the major cause for organ motion, interplay effects depend on the delivery characteristics of proton accelerators. Purpose: To evaluate the impact of different types of PBS proton accelerators and spot sizes on interplay effects, mitigations, and plan quality for Stereotactic Body Radiation Therapy (SBRT) treatment of non‐small cell lung cancer (NSCLC). Methods: Twenty NSCLC patients treated with photon SBRT were selected to represent varying tumor volumes and respiratory motion amplitudes (median: 0.6 cm with abdominal compression) for this retrospective study. For each patient, plans were created using: (1) cyclotron‐generated proton beams (CPB) with spot sizes of σ = 2.7–7.0 mm; (2) linear accelerator proton beams (LPB) (σ = 2.9–5.5 mm); and (3) linear accelerator proton minibeams (LPMB) (σ = 0.9–3.9 mm). The energy switching time is one second for CPB, and 0.005 s for LPMB and LPB. Plans were robustly optimized on the gross tumor volume (GTV) using each individual phase of four‐dimensional computed tomography (4DCT) scans. Initially, single‐field optimization (SFO) plans were evaluated; if the plan quality did not meet the dosimetric requirement, multi‐field optimization (MFO) was used. MFO plans were created for all patients for comparisons. For each patient, all plans were normalized to have the same dose received by 99% of the GTV. Interplay effects were evaluated by computing the dose on 10 breathing phases, based on the spot distribution. Volumetric repainting (VR) was performed 2–6 times for each plan. We compared volume receiving 100% of the prescribed dose (V100%RX) of the GTV, and normal lung V20Gy. Results: Twelve of 20 plans can be optimized sufficiently with SFO. SFO plans were less sensitive to the interplay effect compared to MFO plans in terms of target coverage for both LPB and LPMB. The following comparisons showed results utilizing the MFO technique. In the interplay evaluation without repainting, the mean V100%RX of the GTV were 99.42 ± 0.6%, 97.52 ± 3.9%, and 94.49 ± 7.3% for CPB, LPB, and LPMB plans, respectively. Following VR (2 × for CPB; 3 × for LPB; 5 × for LPMB), V100%RX of the GTV were improved (on average) by 0.13%, 1.84%, and 4.63%, respectively, achieving the acceptance criteria of V100%RX > 95%. Because of fast energy switch in linear accelerator proton machines, the delivery time for VR plans was the lowest for LPB plans, while delivery time for LPMB was on average 1 min longer than CPB plans. The advantage of small spot machines was better sparing in normal lung V20Gy, even when VR was applied. Conclusion: In the absence of repainting, proton machines with large spot sizes generated more robust plans against interplay effects. The number of VR increased with decreasing spot sizes to achieve the acceptance criteria. VR improved the plan robustness against interplay effects for modalities with small spot sizes and fast energy changes, preserving the low dose sparing aspect of the LPMB, even when motion is included. [ABSTRACT FROM AUTHOR]
Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Full text is not displayed to guests.
FullText Links:
  – Type: pdflink
Text:
  Availability: 1
Header DbId: egs
DbLabel: Engineering Source
An: 177626367
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Cyclotron and linear accelerator generated scanning proton beams for lung cancer SBRT: Interplay effects and mitigations.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Liu%2C+Chieh‐Wen%22">Liu, Chieh‐Wen</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Kolano%2C+Anna+M%2E%22">Kolano, Anna M.</searchLink><relatesTo>2,3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Gray%2C+Tara%22">Gray, Tara</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Stephans%2C+Kevin+L%2E%22">Stephans, Kevin L.</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Videtic%2C+Gregory+M%2E+M%2E%22">Videtic, Gregory M. M.</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Farr%2C+Jonathan+B%2E%22">Farr, Jonathan B.</searchLink><relatesTo>2,3</relatesTo> (AUTHOR)<i> jonathan.farr@avo-adam.com</i><br /><searchLink fieldCode="AR" term="%22Xia%2C+Ping%22">Xia, Ping</searchLink><relatesTo>1</relatesTo> (AUTHOR)<i> xiap@ccf.org</i>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Medical+Physics%22">Medical Physics</searchLink>. Jun2024, Vol. 51 Issue 6, p3985-3994. 10p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Proton+accelerators%22">Proton accelerators</searchLink><br /><searchLink fieldCode="DE" term="%22Stereotactic+radiotherapy%22">Stereotactic radiotherapy</searchLink><br /><searchLink fieldCode="DE" term="%22Lung+cancer%22">Lung cancer</searchLink><br /><searchLink fieldCode="DE" term="%22Cyclotrons%22">Cyclotrons</searchLink><br /><searchLink fieldCode="DE" term="%22Proton+beams%22">Proton beams</searchLink><br /><searchLink fieldCode="DE" term="%22Linear+accelerators%22">Linear accelerators</searchLink><br /><searchLink fieldCode="DE" term="%22Non-small-cell+lung+carcinoma%22">Non-small-cell lung carcinoma</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Background: Pencil beam scanning (PBS) proton therapy for moving targets is known to be impacted by interplay effects between the scanning beam and organ motion. While respiratory motion in the thoracic region is the major cause for organ motion, interplay effects depend on the delivery characteristics of proton accelerators. Purpose: To evaluate the impact of different types of PBS proton accelerators and spot sizes on interplay effects, mitigations, and plan quality for Stereotactic Body Radiation Therapy (SBRT) treatment of non‐small cell lung cancer (NSCLC). Methods: Twenty NSCLC patients treated with photon SBRT were selected to represent varying tumor volumes and respiratory motion amplitudes (median: 0.6 cm with abdominal compression) for this retrospective study. For each patient, plans were created using: (1) cyclotron‐generated proton beams (CPB) with spot sizes of σ = 2.7–7.0 mm; (2) linear accelerator proton beams (LPB) (σ = 2.9–5.5 mm); and (3) linear accelerator proton minibeams (LPMB) (σ = 0.9–3.9 mm). The energy switching time is one second for CPB, and 0.005 s for LPMB and LPB. Plans were robustly optimized on the gross tumor volume (GTV) using each individual phase of four‐dimensional computed tomography (4DCT) scans. Initially, single‐field optimization (SFO) plans were evaluated; if the plan quality did not meet the dosimetric requirement, multi‐field optimization (MFO) was used. MFO plans were created for all patients for comparisons. For each patient, all plans were normalized to have the same dose received by 99% of the GTV. Interplay effects were evaluated by computing the dose on 10 breathing phases, based on the spot distribution. Volumetric repainting (VR) was performed 2–6 times for each plan. We compared volume receiving 100% of the prescribed dose (V100%RX) of the GTV, and normal lung V20Gy. Results: Twelve of 20 plans can be optimized sufficiently with SFO. SFO plans were less sensitive to the interplay effect compared to MFO plans in terms of target coverage for both LPB and LPMB. The following comparisons showed results utilizing the MFO technique. In the interplay evaluation without repainting, the mean V100%RX of the GTV were 99.42 ± 0.6%, 97.52 ± 3.9%, and 94.49 ± 7.3% for CPB, LPB, and LPMB plans, respectively. Following VR (2 × for CPB; 3 × for LPB; 5 × for LPMB), V100%RX of the GTV were improved (on average) by 0.13%, 1.84%, and 4.63%, respectively, achieving the acceptance criteria of V100%RX > 95%. Because of fast energy switch in linear accelerator proton machines, the delivery time for VR plans was the lowest for LPB plans, while delivery time for LPMB was on average 1 min longer than CPB plans. The advantage of small spot machines was better sparing in normal lung V20Gy, even when VR was applied. Conclusion: In the absence of repainting, proton machines with large spot sizes generated more robust plans against interplay effects. The number of VR increased with decreasing spot sizes to achieve the acceptance criteria. VR improved the plan robustness against interplay effects for modalities with small spot sizes and fast energy changes, preserving the low dose sparing aspect of the LPMB, even when motion is included. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=177626367
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1002/mp.17082
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 10
        StartPage: 3985
    Subjects:
      – SubjectFull: Proton accelerators
        Type: general
      – SubjectFull: Stereotactic radiotherapy
        Type: general
      – SubjectFull: Lung cancer
        Type: general
      – SubjectFull: Cyclotrons
        Type: general
      – SubjectFull: Proton beams
        Type: general
      – SubjectFull: Linear accelerators
        Type: general
      – SubjectFull: Non-small-cell lung carcinoma
        Type: general
    Titles:
      – TitleFull: Cyclotron and linear accelerator generated scanning proton beams for lung cancer SBRT: Interplay effects and mitigations.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Liu, Chieh‐Wen
      – PersonEntity:
          Name:
            NameFull: Kolano, Anna M.
      – PersonEntity:
          Name:
            NameFull: Gray, Tara
      – PersonEntity:
          Name:
            NameFull: Stephans, Kevin L.
      – PersonEntity:
          Name:
            NameFull: Videtic, Gregory M. M.
      – PersonEntity:
          Name:
            NameFull: Farr, Jonathan B.
      – PersonEntity:
          Name:
            NameFull: Xia, Ping
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 06
              Text: Jun2024
              Type: published
              Y: 2024
          Identifiers:
            – Type: issn-print
              Value: 00942405
          Numbering:
            – Type: volume
              Value: 51
            – Type: issue
              Value: 6
          Titles:
            – TitleFull: Medical Physics
              Type: main
ResultId 1