Comparison of laser and traditional lancing devices for capillary blood sampling in patients with diabetes mellitus and high bleeding risk.
Saved in:
| Title: | Comparison of laser and traditional lancing devices for capillary blood sampling in patients with diabetes mellitus and high bleeding risk. |
|---|---|
| Authors: | Park, Min Jeong1 (AUTHOR), Hwang, Soon Young2 (AUTHOR), Jang, Ahreum1 (AUTHOR), Jang, Soo Yeon1 (AUTHOR), Song, Eyun1 (AUTHOR), Park, So Young1 (AUTHOR), Lee, Da Young1 (AUTHOR), Kim, Jaeyoung3 (AUTHOR), Park, Byung Cheol4 (AUTHOR), Yu, Ji Hee1 (AUTHOR), Seo, Ji A1 (AUTHOR), Choi, Kyung Mook1 (AUTHOR), Baik, Sei Hyun1 (AUTHOR), Yoo, Hye Jin1,5 (AUTHOR) deisy21@korea.ac.kr, Kim, Nan Hee1,6,7 (AUTHOR) nhkendo@gmail.com |
| Source: | Lasers in Medical Science. 7/3/2024, Vol. 39 Issue 1, p1-6. 6p. |
| Subjects: | Blood sampling, Diabetes, Blood sugar monitoring, People with diabetes, Visual analog scale, Hemorrhage |
| Abstract: | Purpose: Despite the importance of self-monitoring blood glucose (SMBG) for management of diabetes mellitus (DM), frequent blood sampling is discouraged by bleeding risk due to dual-antiplatelet agent therapy (DAPT) or thrombocytopenia. Methods: We compared the bleeding time (BT) of sampling by using a laser-lancing-device (LMT-1000) and a conventional lancet in patients with DM and thrombocytopenia or patients undergoing DAPT. BT was measured using the Duke method, and pain and satisfaction scores were assessed using numeric rating scale (NRS) and visual analog scale (VAS). The consistency in the values of glucose and glycated-hemoglobin (HbA1c) sampled using the LMT-1000 or lancet were compared. Results: The BT of sampling with the LMT-1000 was shorter than that with the lancet in patients with thrombocytopenia (60s vs. 85s, P = 0.024). The NRS was lower and the VAS was higher in laser-applied-sampling than lancet-applied sampling in the DAPT-user group (NRS: 1 vs. 2, P = 0.010; VAS: 7 vs. 6, P = 0.003), whereas the group with thrombocytopenia only showed improvement in the VAS score (8 vs. 7, P = 0.049). Glucose and HbA1c sampled by the LMT-1000 and lancet were significantly correlated in both the DAPT-user and the thrombocytopenia groups. Conclusion: The LMT-1000 can promote SMBG by shortening BT in subject with thrombocytopenia and by increasing satisfaction score, as well as by showing reliable glucose and HbA1c value. [ABSTRACT FROM AUTHOR] |
| Copyright of Lasers in Medical Science is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
|
Full text is not displayed to guests.
Login for full access.
|
|
| FullText | Links: – Type: pdflink Text: Availability: 1 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 178231513 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Comparison of laser and traditional lancing devices for capillary blood sampling in patients with diabetes mellitus and high bleeding risk. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Park%2C+Min+Jeong%22">Park, Min Jeong</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Hwang%2C+Soon+Young%22">Hwang, Soon Young</searchLink><relatesTo>2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Jang%2C+Ahreum%22">Jang, Ahreum</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Jang%2C+Soo+Yeon%22">Jang, Soo Yeon</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Song%2C+Eyun%22">Song, Eyun</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Park%2C+So+Young%22">Park, So Young</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Lee%2C+Da+Young%22">Lee, Da Young</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Kim%2C+Jaeyoung%22">Kim, Jaeyoung</searchLink><relatesTo>3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Park%2C+Byung+Cheol%22">Park, Byung Cheol</searchLink><relatesTo>4</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Yu%2C+Ji+Hee%22">Yu, Ji Hee</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Seo%2C+Ji+A%22">Seo, Ji A</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Choi%2C+Kyung+Mook%22">Choi, Kyung Mook</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Baik%2C+Sei+Hyun%22">Baik, Sei Hyun</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Yoo%2C+Hye+Jin%22">Yoo, Hye Jin</searchLink><relatesTo>1,5</relatesTo> (AUTHOR)<i> deisy21@korea.ac.kr</i><br /><searchLink fieldCode="AR" term="%22Kim%2C+Nan+Hee%22">Kim, Nan Hee</searchLink><relatesTo>1,6,7</relatesTo> (AUTHOR)<i> nhkendo@gmail.com</i> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Lasers+in+Medical+Science%22">Lasers in Medical Science</searchLink>. 7/3/2024, Vol. 39 Issue 1, p1-6. 6p. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22Blood+sampling%22">Blood sampling</searchLink><br /><searchLink fieldCode="DE" term="%22Diabetes%22">Diabetes</searchLink><br /><searchLink fieldCode="DE" term="%22Blood+sugar+monitoring%22">Blood sugar monitoring</searchLink><br /><searchLink fieldCode="DE" term="%22People+with+diabetes%22">People with diabetes</searchLink><br /><searchLink fieldCode="DE" term="%22Visual+analog+scale%22">Visual analog scale</searchLink><br /><searchLink fieldCode="DE" term="%22Hemorrhage%22">Hemorrhage</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: Purpose: Despite the importance of self-monitoring blood glucose (SMBG) for management of diabetes mellitus (DM), frequent blood sampling is discouraged by bleeding risk due to dual-antiplatelet agent therapy (DAPT) or thrombocytopenia. Methods: We compared the bleeding time (BT) of sampling by using a laser-lancing-device (LMT-1000) and a conventional lancet in patients with DM and thrombocytopenia or patients undergoing DAPT. BT was measured using the Duke method, and pain and satisfaction scores were assessed using numeric rating scale (NRS) and visual analog scale (VAS). The consistency in the values of glucose and glycated-hemoglobin (HbA1c) sampled using the LMT-1000 or lancet were compared. Results: The BT of sampling with the LMT-1000 was shorter than that with the lancet in patients with thrombocytopenia (60s vs. 85s, P = 0.024). The NRS was lower and the VAS was higher in laser-applied-sampling than lancet-applied sampling in the DAPT-user group (NRS: 1 vs. 2, P = 0.010; VAS: 7 vs. 6, P = 0.003), whereas the group with thrombocytopenia only showed improvement in the VAS score (8 vs. 7, P = 0.049). Glucose and HbA1c sampled by the LMT-1000 and lancet were significantly correlated in both the DAPT-user and the thrombocytopenia groups. Conclusion: The LMT-1000 can promote SMBG by shortening BT in subject with thrombocytopenia and by increasing satisfaction score, as well as by showing reliable glucose and HbA1c value. [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of Lasers in Medical Science is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=178231513 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1007/s10103-024-04128-6 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 6 StartPage: 1 Subjects: – SubjectFull: Blood sampling Type: general – SubjectFull: Diabetes Type: general – SubjectFull: Blood sugar monitoring Type: general – SubjectFull: People with diabetes Type: general – SubjectFull: Visual analog scale Type: general – SubjectFull: Hemorrhage Type: general Titles: – TitleFull: Comparison of laser and traditional lancing devices for capillary blood sampling in patients with diabetes mellitus and high bleeding risk. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Park, Min Jeong – PersonEntity: Name: NameFull: Hwang, Soon Young – PersonEntity: Name: NameFull: Jang, Ahreum – PersonEntity: Name: NameFull: Jang, Soo Yeon – PersonEntity: Name: NameFull: Song, Eyun – PersonEntity: Name: NameFull: Park, So Young – PersonEntity: Name: NameFull: Lee, Da Young – PersonEntity: Name: NameFull: Kim, Jaeyoung – PersonEntity: Name: NameFull: Park, Byung Cheol – PersonEntity: Name: NameFull: Yu, Ji Hee – PersonEntity: Name: NameFull: Seo, Ji A – PersonEntity: Name: NameFull: Choi, Kyung Mook – PersonEntity: Name: NameFull: Baik, Sei Hyun – PersonEntity: Name: NameFull: Yoo, Hye Jin – PersonEntity: Name: NameFull: Kim, Nan Hee IsPartOfRelationships: – BibEntity: Dates: – D: 03 M: 07 Text: 7/3/2024 Type: published Y: 2024 Identifiers: – Type: issn-print Value: 02688921 Numbering: – Type: volume Value: 39 – Type: issue Value: 1 Titles: – TitleFull: Lasers in Medical Science Type: main |
| ResultId | 1 |