Properties and energy performance of wood waste sustainable panels resulting from the fabrication of innovative monolithic aerogel glazing systems.

Saved in:
Bibliographic Details
Title: Properties and energy performance of wood waste sustainable panels resulting from the fabrication of innovative monolithic aerogel glazing systems.
Authors: Merli, F.1 (AUTHOR), Buratti, C.1 (AUTHOR) cinzia.buratti@unipg.it
Source: Construction & Building Materials. Aug2024, Vol. 438, pN.PAG-N.PAG. 1p.
Subjects: Wood waste, Manufacturing processes, Aerogels, Thermal resistance, Wood, Industrial wastes
Abstract: The combined effect of pine wood waste panels resulting from the different industrial processes to produce window frames and double glazing systems with monolithic aerogel of different hydrophobicity in the gap on the heating, cooling, and artificial lighting energy demand of a typical 70 s residential building in different climatic conditions is evaluated. The scraps obtained from the production of the innovative transparent glazing systems are used to fabricate eco-sustainable panels using natural flour-based glue. A thermal conductivity value of the opaque panels equal to 0.077 W/mK is measured by means of a thermal flux meter methodology. As regards the glazing systems, thermal resistance values of 0.86 and 0.92 m2K/W are measured for hydrophilic HY 0 and hydrophobic HY 10 unit, respectively; as a consequence, a thermal transmittance reduction equal to 65–67 % is obtained with respect to the double glazing unit with air in the gap. However, visible transmittance equal to 0.66 is measured as increasing hydrophobicity with respect to 0.81 of the conventional air glazing unit (reduction of 16 and 19 % with HY 0 and HY 10, respectively), as measured by means of a large integrating sphere spectrophotometer. The experimental data measured on eco-sustainable opaque panels and innovative transparent solutions are implemented in dynamic simulation models. The results show an annual heating energy demand reductions (in the 17 (Bolzano) – 39 % (Palermo) range) and cooling (in the 2 (Bolzano) – 11 % (Rome) range) in different climatic areas. Hydrophobicity has a negligible influence on the results. On the other hand, the energy demand for artificial lighting is not affected by the investigated solutions (maximum increase of 10 % is obtained in Bolzano with hydrophobic glazing system). This work is preparatory for the future possibility of starting a production chain of wood fiber insulating panels in the area, which will be in case fabricated at industrial scale in order to reduce the environmental impacts in the construction process of a building in a circular economy perspective and to improve the energy efficiency of the building envelopes by means of innovative materials. • the recovery of wood waste resulting from the industrial processes is encouraged. • combined effect of eco-sustainable panels and innovative are investigated. • experimental data are used in dynamic simulations. • heating energy demand reduction up to 24 % is obtained in temperate climate. • the study is the basis for the development of industrial wooden waste chains. [ABSTRACT FROM AUTHOR]
Copyright of Construction & Building Materials is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 178335702
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Properties and energy performance of wood waste sustainable panels resulting from the fabrication of innovative monolithic aerogel glazing systems.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Merli%2C+F%2E%22">Merli, F.</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Buratti%2C+C%2E%22">Buratti, C.</searchLink><relatesTo>1</relatesTo> (AUTHOR)<i> cinzia.buratti@unipg.it</i>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Construction+%26+Building+Materials%22">Construction & Building Materials</searchLink>. Aug2024, Vol. 438, pN.PAG-N.PAG. 1p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Wood+waste%22">Wood waste</searchLink><br /><searchLink fieldCode="DE" term="%22Manufacturing+processes%22">Manufacturing processes</searchLink><br /><searchLink fieldCode="DE" term="%22Aerogels%22">Aerogels</searchLink><br /><searchLink fieldCode="DE" term="%22Thermal+resistance%22">Thermal resistance</searchLink><br /><searchLink fieldCode="DE" term="%22Wood%22">Wood</searchLink><br /><searchLink fieldCode="DE" term="%22Industrial+wastes%22">Industrial wastes</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: The combined effect of pine wood waste panels resulting from the different industrial processes to produce window frames and double glazing systems with monolithic aerogel of different hydrophobicity in the gap on the heating, cooling, and artificial lighting energy demand of a typical 70 s residential building in different climatic conditions is evaluated. The scraps obtained from the production of the innovative transparent glazing systems are used to fabricate eco-sustainable panels using natural flour-based glue. A thermal conductivity value of the opaque panels equal to 0.077 W/mK is measured by means of a thermal flux meter methodology. As regards the glazing systems, thermal resistance values of 0.86 and 0.92 m2K/W are measured for hydrophilic HY 0 and hydrophobic HY 10 unit, respectively; as a consequence, a thermal transmittance reduction equal to 65–67 % is obtained with respect to the double glazing unit with air in the gap. However, visible transmittance equal to 0.66 is measured as increasing hydrophobicity with respect to 0.81 of the conventional air glazing unit (reduction of 16 and 19 % with HY 0 and HY 10, respectively), as measured by means of a large integrating sphere spectrophotometer. The experimental data measured on eco-sustainable opaque panels and innovative transparent solutions are implemented in dynamic simulation models. The results show an annual heating energy demand reductions (in the 17 (Bolzano) – 39 % (Palermo) range) and cooling (in the 2 (Bolzano) – 11 % (Rome) range) in different climatic areas. Hydrophobicity has a negligible influence on the results. On the other hand, the energy demand for artificial lighting is not affected by the investigated solutions (maximum increase of 10 % is obtained in Bolzano with hydrophobic glazing system). This work is preparatory for the future possibility of starting a production chain of wood fiber insulating panels in the area, which will be in case fabricated at industrial scale in order to reduce the environmental impacts in the construction process of a building in a circular economy perspective and to improve the energy efficiency of the building envelopes by means of innovative materials. • the recovery of wood waste resulting from the industrial processes is encouraged. • combined effect of eco-sustainable panels and innovative are investigated. • experimental data are used in dynamic simulations. • heating energy demand reduction up to 24 % is obtained in temperate climate. • the study is the basis for the development of industrial wooden waste chains. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Construction & Building Materials is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=178335702
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1016/j.conbuildmat.2024.137310
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 1
        StartPage: N.PAG
    Subjects:
      – SubjectFull: Wood waste
        Type: general
      – SubjectFull: Manufacturing processes
        Type: general
      – SubjectFull: Aerogels
        Type: general
      – SubjectFull: Thermal resistance
        Type: general
      – SubjectFull: Wood
        Type: general
      – SubjectFull: Industrial wastes
        Type: general
    Titles:
      – TitleFull: Properties and energy performance of wood waste sustainable panels resulting from the fabrication of innovative monolithic aerogel glazing systems.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Merli, F.
      – PersonEntity:
          Name:
            NameFull: Buratti, C.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 09
              M: 08
              Text: Aug2024
              Type: published
              Y: 2024
          Identifiers:
            – Type: issn-print
              Value: 09500618
          Numbering:
            – Type: volume
              Value: 438
          Titles:
            – TitleFull: Construction & Building Materials
              Type: main
ResultId 1