Influence of using different toothpaste during bleaching with violet LED light (405 nm) on the colour and roughness of dental enamel: an in vitro study.

Saved in:
Bibliographic Details
Title: Influence of using different toothpaste during bleaching with violet LED light (405 nm) on the colour and roughness of dental enamel: an in vitro study.
Authors: Leticia, Franco Sousa1 (AUTHOR), Victor, Mazzalli Redondo1 (AUTHOR), Laura, Ferraz Nobre1 (AUTHOR), Rafael, Vitti Pino1 (AUTHOR), Scatolin, Renata Siqueira1 (AUTHOR) re_scatolin@hotmail.com
Source: Lasers in Medical Science. 8/15/2024, Vol. 39 Issue 1, p1-8. 8p.
Subjects: Dental enamel, Scanning electron microscopy, Surface roughness, Toothpaste, Incisors
Abstract: This in vitro study aimed to investigate potential changes in the color and roughness of dental enamel resulting from the use of different toothpaste formulations during bleaching with violet LED light (405 nm). Sixty specimens of bovine incisors, each measuring 6 × 6 × 3 mm, were segregated into six distinct experimental groups based on their respective treatments (n = 10): C + VL: Brushing with Colgate® Total 12 + bleaching with violet LED; LB + VL: Brushing with Colgate® Luminous White Brilliant + bleaching with violet LED; LI + VL: Brushing with Colgate® Luminous White Instant + violet LED bleaching; C: Brushing with Colgate® Total 12; LB: Brushing with Colgate® Luminous White Brilliant; LI: Brushing with Colgate® Luminous White Instant. The examined variables included alterations in color (∆L*, ∆a*, ∆b*, ∆Eab, and ∆E00), surface roughness (Ra), and scanning electron microscopy observations. No statistically significant distinctions emerged in total color variations (∆E00 and ∆E) among the groups under scrutiny. Notably, the groups that employed Colgate® Luminous White Instant displayed elevated roughness values, irrespective of their association with violet LED, as corroborated by scanning electron microscopy examinations. It can be concluded that whitening toothpastes associated to violet LED do not influence the color change of dental enamel in fifteen days of treatment. Toothpastes with a higher number of abrasive particles showed greater changes in enamel roughness, regardless of the use of violet LED. [ABSTRACT FROM AUTHOR]
Copyright of Lasers in Medical Science is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Full text is not displayed to guests.
FullText Links:
  – Type: pdflink
Text:
  Availability: 1
Header DbId: egs
DbLabel: Engineering Source
An: 179041188
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Influence of using different toothpaste during bleaching with violet LED light (405 nm) on the colour and roughness of dental enamel: an in vitro study.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Leticia%2C+Franco+Sousa%22">Leticia, Franco Sousa</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Victor%2C+Mazzalli+Redondo%22">Victor, Mazzalli Redondo</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Laura%2C+Ferraz+Nobre%22">Laura, Ferraz Nobre</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Rafael%2C+Vitti+Pino%22">Rafael, Vitti Pino</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Scatolin%2C+Renata+Siqueira%22">Scatolin, Renata Siqueira</searchLink><relatesTo>1</relatesTo> (AUTHOR)<i> re_scatolin@hotmail.com</i>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Lasers+in+Medical+Science%22">Lasers in Medical Science</searchLink>. 8/15/2024, Vol. 39 Issue 1, p1-8. 8p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Dental+enamel%22">Dental enamel</searchLink><br /><searchLink fieldCode="DE" term="%22Scanning+electron+microscopy%22">Scanning electron microscopy</searchLink><br /><searchLink fieldCode="DE" term="%22Surface+roughness%22">Surface roughness</searchLink><br /><searchLink fieldCode="DE" term="%22Toothpaste%22">Toothpaste</searchLink><br /><searchLink fieldCode="DE" term="%22Incisors%22">Incisors</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: This in vitro study aimed to investigate potential changes in the color and roughness of dental enamel resulting from the use of different toothpaste formulations during bleaching with violet LED light (405 nm). Sixty specimens of bovine incisors, each measuring 6 × 6 × 3 mm, were segregated into six distinct experimental groups based on their respective treatments (n = 10): C + VL: Brushing with Colgate® Total 12 + bleaching with violet LED; LB + VL: Brushing with Colgate® Luminous White Brilliant + bleaching with violet LED; LI + VL: Brushing with Colgate® Luminous White Instant + violet LED bleaching; C: Brushing with Colgate® Total 12; LB: Brushing with Colgate® Luminous White Brilliant; LI: Brushing with Colgate® Luminous White Instant. The examined variables included alterations in color (∆L*, ∆a*, ∆b*, ∆Eab, and ∆E00), surface roughness (Ra), and scanning electron microscopy observations. No statistically significant distinctions emerged in total color variations (∆E00 and ∆E) among the groups under scrutiny. Notably, the groups that employed Colgate® Luminous White Instant displayed elevated roughness values, irrespective of their association with violet LED, as corroborated by scanning electron microscopy examinations. It can be concluded that whitening toothpastes associated to violet LED do not influence the color change of dental enamel in fifteen days of treatment. Toothpastes with a higher number of abrasive particles showed greater changes in enamel roughness, regardless of the use of violet LED. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Lasers in Medical Science is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=179041188
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1007/s10103-024-04161-5
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 8
        StartPage: 1
    Subjects:
      – SubjectFull: Dental enamel
        Type: general
      – SubjectFull: Scanning electron microscopy
        Type: general
      – SubjectFull: Surface roughness
        Type: general
      – SubjectFull: Toothpaste
        Type: general
      – SubjectFull: Incisors
        Type: general
    Titles:
      – TitleFull: Influence of using different toothpaste during bleaching with violet LED light (405 nm) on the colour and roughness of dental enamel: an in vitro study.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Leticia, Franco Sousa
      – PersonEntity:
          Name:
            NameFull: Victor, Mazzalli Redondo
      – PersonEntity:
          Name:
            NameFull: Laura, Ferraz Nobre
      – PersonEntity:
          Name:
            NameFull: Rafael, Vitti Pino
      – PersonEntity:
          Name:
            NameFull: Scatolin, Renata Siqueira
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 15
              M: 08
              Text: 8/15/2024
              Type: published
              Y: 2024
          Identifiers:
            – Type: issn-print
              Value: 02688921
          Numbering:
            – Type: volume
              Value: 39
            – Type: issue
              Value: 1
          Titles:
            – TitleFull: Lasers in Medical Science
              Type: main
ResultId 1