Biofidelity and Limitations of Instrumented Mouthguard Systems for Assessment of Rigid Body Head Kinematics.

Saved in:
Bibliographic Details
Title: Biofidelity and Limitations of Instrumented Mouthguard Systems for Assessment of Rigid Body Head Kinematics.
Authors: Abrams, Mitchell Z.1 (AUTHOR) mitchell.abrams@duke.edu, Venkatraman, Jay2 (AUTHOR), Sherman, Donald2 (AUTHOR), Ortiz-Paparoni, Maria1 (AUTHOR), Bercaw, Jefferson R.1 (AUTHOR), MacDonald, Robert E.2 (AUTHOR), Kait, Jason1 (AUTHOR), Dimbath, Elizabeth D.1 (AUTHOR), Pang, Derek Y.1 (AUTHOR), Gray, Alexandra1 (AUTHOR), Luck, Jason F.1 (AUTHOR), Bir, Cynthia A.2 (AUTHOR), Bass, Cameron R.1,2 (AUTHOR)
Source: Annals of Biomedical Engineering. Oct2024, Vol. 52 Issue 10, p2872-2883. 12p.
Subjects: Linear acceleration, Football helmets, Center of mass, Angular acceleration, Angular velocity
Abstract: Instrumented mouthguard systems (iMGs) are commonly used to study rigid body head kinematics across a variety of athletic environments. Previous work has found good fidelity for iMGs rigidly fixed to anthropomorphic test device (ATD) headforms when compared to reference systems, but few validation studies have focused on iMG performance in human cadaver heads. Here, we examine the performance of two boil-and-bite style iMGs in helmeted cadaver heads. Three unembalmed human cadaver heads were fitted with two instrumented boil-and-bite mouthguards [Prevent Biometrics and Diversified Technical Systems (DTS)] per manufacturer instructions. Reference sensors were rigidly fixed to each specimen. Specimens were fitted with a Riddell SpeedFlex American football helmet and impacted with a rigid impactor at three velocities and locations. All impact kinematics were compared at the head center of gravity. The Prevent iMG performed comparably to the reference system up to ~ 60 g in linear acceleration, but overall had poor correlation (CCC = 0.39). Prevent iMG angular velocity and BrIC generally well correlated with the reference, while underestimating HIC and overestimating HIC duration. The DTS iMG consistently overestimated the reference across all measures, with linear acceleration error ranging from 10 to 66%, and angular acceleration errors greater than 300%. Neither iMG demonstrated consistent agreement with the reference system. While iMG validation efforts have utilized ATD testing, this study highlights the need for cadaver testing and validation of devices intended for use in-vivo, particularly when considering realistic (non-idealized) sensor-skull coupling, when accounting for interactions with the mandible and when subject-specific anatomy may affect device performance. [ABSTRACT FROM AUTHOR]
Copyright of Annals of Biomedical Engineering is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Full text is not displayed to guests.
FullText Links:
  – Type: pdflink
Text:
  Availability: 1
Header DbId: egs
DbLabel: Engineering Source
An: 179669143
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Biofidelity and Limitations of Instrumented Mouthguard Systems for Assessment of Rigid Body Head Kinematics.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Abrams%2C+Mitchell+Z%2E%22">Abrams, Mitchell Z.</searchLink><relatesTo>1</relatesTo> (AUTHOR)<i> mitchell.abrams@duke.edu</i><br /><searchLink fieldCode="AR" term="%22Venkatraman%2C+Jay%22">Venkatraman, Jay</searchLink><relatesTo>2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Sherman%2C+Donald%22">Sherman, Donald</searchLink><relatesTo>2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Ortiz-Paparoni%2C+Maria%22">Ortiz-Paparoni, Maria</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Bercaw%2C+Jefferson+R%2E%22">Bercaw, Jefferson R.</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22MacDonald%2C+Robert+E%2E%22">MacDonald, Robert E.</searchLink><relatesTo>2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Kait%2C+Jason%22">Kait, Jason</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Dimbath%2C+Elizabeth+D%2E%22">Dimbath, Elizabeth D.</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Pang%2C+Derek+Y%2E%22">Pang, Derek Y.</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Gray%2C+Alexandra%22">Gray, Alexandra</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Luck%2C+Jason+F%2E%22">Luck, Jason F.</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Bir%2C+Cynthia+A%2E%22">Bir, Cynthia A.</searchLink><relatesTo>2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Bass%2C+Cameron+R%2E%22">Bass, Cameron R.</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Annals+of+Biomedical+Engineering%22">Annals of Biomedical Engineering</searchLink>. Oct2024, Vol. 52 Issue 10, p2872-2883. 12p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Linear+acceleration%22">Linear acceleration</searchLink><br /><searchLink fieldCode="DE" term="%22Football+helmets%22">Football helmets</searchLink><br /><searchLink fieldCode="DE" term="%22Center+of+mass%22">Center of mass</searchLink><br /><searchLink fieldCode="DE" term="%22Angular+acceleration%22">Angular acceleration</searchLink><br /><searchLink fieldCode="DE" term="%22Angular+velocity%22">Angular velocity</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Instrumented mouthguard systems (iMGs) are commonly used to study rigid body head kinematics across a variety of athletic environments. Previous work has found good fidelity for iMGs rigidly fixed to anthropomorphic test device (ATD) headforms when compared to reference systems, but few validation studies have focused on iMG performance in human cadaver heads. Here, we examine the performance of two boil-and-bite style iMGs in helmeted cadaver heads. Three unembalmed human cadaver heads were fitted with two instrumented boil-and-bite mouthguards [Prevent Biometrics and Diversified Technical Systems (DTS)] per manufacturer instructions. Reference sensors were rigidly fixed to each specimen. Specimens were fitted with a Riddell SpeedFlex American football helmet and impacted with a rigid impactor at three velocities and locations. All impact kinematics were compared at the head center of gravity. The Prevent iMG performed comparably to the reference system up to ~ 60 g in linear acceleration, but overall had poor correlation (CCC = 0.39). Prevent iMG angular velocity and BrIC generally well correlated with the reference, while underestimating HIC and overestimating HIC duration. The DTS iMG consistently overestimated the reference across all measures, with linear acceleration error ranging from 10 to 66%, and angular acceleration errors greater than 300%. Neither iMG demonstrated consistent agreement with the reference system. While iMG validation efforts have utilized ATD testing, this study highlights the need for cadaver testing and validation of devices intended for use in-vivo, particularly when considering realistic (non-idealized) sensor-skull coupling, when accounting for interactions with the mandible and when subject-specific anatomy may affect device performance. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Annals of Biomedical Engineering is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=179669143
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1007/s10439-024-03563-4
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 12
        StartPage: 2872
    Subjects:
      – SubjectFull: Linear acceleration
        Type: general
      – SubjectFull: Football helmets
        Type: general
      – SubjectFull: Center of mass
        Type: general
      – SubjectFull: Angular acceleration
        Type: general
      – SubjectFull: Angular velocity
        Type: general
    Titles:
      – TitleFull: Biofidelity and Limitations of Instrumented Mouthguard Systems for Assessment of Rigid Body Head Kinematics.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Abrams, Mitchell Z.
      – PersonEntity:
          Name:
            NameFull: Venkatraman, Jay
      – PersonEntity:
          Name:
            NameFull: Sherman, Donald
      – PersonEntity:
          Name:
            NameFull: Ortiz-Paparoni, Maria
      – PersonEntity:
          Name:
            NameFull: Bercaw, Jefferson R.
      – PersonEntity:
          Name:
            NameFull: MacDonald, Robert E.
      – PersonEntity:
          Name:
            NameFull: Kait, Jason
      – PersonEntity:
          Name:
            NameFull: Dimbath, Elizabeth D.
      – PersonEntity:
          Name:
            NameFull: Pang, Derek Y.
      – PersonEntity:
          Name:
            NameFull: Gray, Alexandra
      – PersonEntity:
          Name:
            NameFull: Luck, Jason F.
      – PersonEntity:
          Name:
            NameFull: Bir, Cynthia A.
      – PersonEntity:
          Name:
            NameFull: Bass, Cameron R.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 10
              Text: Oct2024
              Type: published
              Y: 2024
          Identifiers:
            – Type: issn-print
              Value: 00906964
          Numbering:
            – Type: volume
              Value: 52
            – Type: issue
              Value: 10
          Titles:
            – TitleFull: Annals of Biomedical Engineering
              Type: main
ResultId 1