Characterization of neutron-irradiated SiPMs down to liquid nitrogen temperature.

Saved in:
Bibliographic Details
Title: Characterization of neutron-irradiated SiPMs down to liquid nitrogen temperature.
Authors: Consuegra Rodríguez, Dania1 (AUTHOR) dania.consuegra@ijs.si, Dolenec, Rok1,2 (AUTHOR), Križan, Peter1,2 (AUTHOR), Korpar, Samo1,3 (AUTHOR), Seljak, Andrej1 (AUTHOR), Žontar, Dejan1 (AUTHOR), Pestotnik, Rok1 (AUTHOR)
Source: European Physical Journal C -- Particles & Fields. Sep2024, Vol. 84 Issue 9, p1-14. 14p.
Subjects: Large Hadron Collider, Cherenkov counters, Wave analysis, Image converters, Nuclear reactors, Photon detectors
Abstract: Photodetectors used in future high-energy physics experiments will need to keep sufficient performance during a few years of data-taking despite radiation load, which, for example, in the planned upgrade of the Ring Imaging Cherenkov detectors in Large Hadron Collider beauty (LHCb) experiment is estimated at about 10 13 1-MeV neutron equivalent per cm 2 (neq/cm 2 ). Silicon photomultipliers (SiPMs) are considered as candidates for photodetectors for this application. However, their sensitivity to neutron irradiation may seriously compromise their operation, with the increase in dark count rates being the primary limitation after the irradiation. In this work, 1 × 1 mm 2 15 μ m pitch NUV-HD-RH silicon photomultipliers developed by the Fondazione Bruno Kessler were characterized before and after the irradiation. In total, 5 SiPMs were irradiated at the Jožef Stefan Institute TRIGA nuclear reactor with different fluences from 10 9 neq/cm 2 up to 10 13 neq/cm 2 . The SiPMs were also annealed at high temperatures and re-characterized after the annealing. For the SiPM characterization in all the cases, current–voltage (I-V curve) measurements, dark count rate measurements, and waveform analysis, including single photon time resolution, were carried out at different controlled temperature steps from room temperature down to the liquid nitrogen temperature. While cooling to − 20 ∘ C was enough for the SiPM irradiated at 10 9 neq/cm 2 to recover the ability to resolve single photons, by 10 13 neq/cm 2 , cooling to liquid nitrogen temperature was necessary. With sufficient cooling, the measured single photon time resolution was around 90 ps FWHM for all irradiation levels. [ABSTRACT FROM AUTHOR]
Copyright of European Physical Journal C -- Particles & Fields is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Full text is not displayed to guests.
FullText Links:
  – Type: pdflink
Text:
  Availability: 1
Header DbId: egs
DbLabel: Engineering Source
An: 180253700
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Characterization of neutron-irradiated SiPMs down to liquid nitrogen temperature.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Consuegra+Rodríguez%2C+Dania%22">Consuegra Rodríguez, Dania</searchLink><relatesTo>1</relatesTo> (AUTHOR)<i> dania.consuegra@ijs.si</i><br /><searchLink fieldCode="AR" term="%22Dolenec%2C+Rok%22">Dolenec, Rok</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Križan%2C+Peter%22">Križan, Peter</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Korpar%2C+Samo%22">Korpar, Samo</searchLink><relatesTo>1,3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Seljak%2C+Andrej%22">Seljak, Andrej</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Žontar%2C+Dejan%22">Žontar, Dejan</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Pestotnik%2C+Rok%22">Pestotnik, Rok</searchLink><relatesTo>1</relatesTo> (AUTHOR)
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22European+Physical+Journal+C+--+Particles+%26+Fields%22">European Physical Journal C -- Particles & Fields</searchLink>. Sep2024, Vol. 84 Issue 9, p1-14. 14p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Large+Hadron+Collider%22">Large Hadron Collider</searchLink><br /><searchLink fieldCode="DE" term="%22Cherenkov+counters%22">Cherenkov counters</searchLink><br /><searchLink fieldCode="DE" term="%22Wave+analysis%22">Wave analysis</searchLink><br /><searchLink fieldCode="DE" term="%22Image+converters%22">Image converters</searchLink><br /><searchLink fieldCode="DE" term="%22Nuclear+reactors%22">Nuclear reactors</searchLink><br /><searchLink fieldCode="DE" term="%22Photon+detectors%22">Photon detectors</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Photodetectors used in future high-energy physics experiments will need to keep sufficient performance during a few years of data-taking despite radiation load, which, for example, in the planned upgrade of the Ring Imaging Cherenkov detectors in Large Hadron Collider beauty (LHCb) experiment is estimated at about 10 13 1-MeV neutron equivalent per cm 2 (neq/cm 2 ). Silicon photomultipliers (SiPMs) are considered as candidates for photodetectors for this application. However, their sensitivity to neutron irradiation may seriously compromise their operation, with the increase in dark count rates being the primary limitation after the irradiation. In this work, 1 × 1 mm 2 15 μ m pitch NUV-HD-RH silicon photomultipliers developed by the Fondazione Bruno Kessler were characterized before and after the irradiation. In total, 5 SiPMs were irradiated at the Jožef Stefan Institute TRIGA nuclear reactor with different fluences from 10 9 neq/cm 2 up to 10 13 neq/cm 2 . The SiPMs were also annealed at high temperatures and re-characterized after the annealing. For the SiPM characterization in all the cases, current–voltage (I-V curve) measurements, dark count rate measurements, and waveform analysis, including single photon time resolution, were carried out at different controlled temperature steps from room temperature down to the liquid nitrogen temperature. While cooling to − 20 ∘ C was enough for the SiPM irradiated at 10 9 neq/cm 2 to recover the ability to resolve single photons, by 10 13 neq/cm 2 , cooling to liquid nitrogen temperature was necessary. With sufficient cooling, the measured single photon time resolution was around 90 ps FWHM for all irradiation levels. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of European Physical Journal C -- Particles & Fields is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=180253700
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1140/epjc/s10052-024-13302-7
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 14
        StartPage: 1
    Subjects:
      – SubjectFull: Large Hadron Collider
        Type: general
      – SubjectFull: Cherenkov counters
        Type: general
      – SubjectFull: Wave analysis
        Type: general
      – SubjectFull: Image converters
        Type: general
      – SubjectFull: Nuclear reactors
        Type: general
      – SubjectFull: Photon detectors
        Type: general
    Titles:
      – TitleFull: Characterization of neutron-irradiated SiPMs down to liquid nitrogen temperature.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Consuegra Rodríguez, Dania
      – PersonEntity:
          Name:
            NameFull: Dolenec, Rok
      – PersonEntity:
          Name:
            NameFull: Križan, Peter
      – PersonEntity:
          Name:
            NameFull: Korpar, Samo
      – PersonEntity:
          Name:
            NameFull: Seljak, Andrej
      – PersonEntity:
          Name:
            NameFull: Žontar, Dejan
      – PersonEntity:
          Name:
            NameFull: Pestotnik, Rok
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 09
              Text: Sep2024
              Type: published
              Y: 2024
          Identifiers:
            – Type: issn-print
              Value: 14346044
          Numbering:
            – Type: volume
              Value: 84
            – Type: issue
              Value: 9
          Titles:
            – TitleFull: European Physical Journal C -- Particles & Fields
              Type: main
ResultId 1