Gradient‐induced vibrations and motion‐induced Lenz effects on conductive nonmagnetic orthopedic implants in MRI.
Saved in:
| Title: | Gradient‐induced vibrations and motion‐induced Lenz effects on conductive nonmagnetic orthopedic implants in MRI. |
|---|---|
| Authors: | Zilberti, Luca1 (AUTHOR) l.zilberti@inrim.it, Curreli, Cristina2 (AUTHOR), Arduino, Alessandro1 (AUTHOR), Zanovello, Umberto1 (AUTHOR), Baruffaldi, Fabio2 (AUTHOR), Bottauscio, Oriano1 (AUTHOR) |
| Source: | Magnetic Resonance in Medicine. Jan2025, Vol. 93 Issue 1, p341-352. 12p. |
| Subjects: | Vibration (Mechanics), Mechanical loads, Orthopedic implants, Frequencies of oscillating systems, Lorentz force |
| Abstract: | Purpose: To quantify the extent of gradient‐induced vibrations, and the magnitude of motion‐induced displacement forces ("Lenz effect"), in conductive nonmagnetic orthopedic prostheses. Methods: The investigation is carried out through numerical simulations, for a 3 T scanner. For gradient‐induced torques and vibrations, a knee and a shoulder implant are considered, at dB/dt equal to 42 T/s (rms). For motion‐induced forces associated with the Lenz effect, a knee and a hip implant are studied, considering a patient who translates on the examination couch, or walks next to it. Results: Gradient‐induced torques may be within the same order of magnitude as the worst case gravitational torque defined in the ASTM standards. However, for all investigated cases, they result to be lower. In vacuum, the extent of the corresponding vibration reduces with frequency. At the lowest investigated frequency (270 Hz), it keeps below 25 μm. For an implant partially embedded in bone, the extent of the vibration increases with frequency. Nevertheless, the displacement is far lower than the worst case observed in vacuum (negligible in contact with the bone; ˜1 μm or less where the implant emerges from the bone). The Lenz effect induced by the motion of the patient through the stationary magnetic field produces forces on the order of a few millinewtons (i.e., at least two orders of magnitude lower than the implant weight). Conclusion: Comparing the results with mechanical loads caused by ordinary activities of daily living, and with the levels of tolerable micromotions, a good safety margin is confirmed. [ABSTRACT FROM AUTHOR] |
| Copyright of Magnetic Resonance in Medicine is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
|
Full text is not displayed to guests.
Login for full access.
|
|
| FullText | Links: – Type: pdflink Text: Availability: 1 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 180521859 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Gradient‐induced vibrations and motion‐induced Lenz effects on conductive nonmagnetic orthopedic implants in MRI. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Zilberti%2C+Luca%22">Zilberti, Luca</searchLink><relatesTo>1</relatesTo> (AUTHOR)<i> l.zilberti@inrim.it</i><br /><searchLink fieldCode="AR" term="%22Curreli%2C+Cristina%22">Curreli, Cristina</searchLink><relatesTo>2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Arduino%2C+Alessandro%22">Arduino, Alessandro</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Zanovello%2C+Umberto%22">Zanovello, Umberto</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Baruffaldi%2C+Fabio%22">Baruffaldi, Fabio</searchLink><relatesTo>2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Bottauscio%2C+Oriano%22">Bottauscio, Oriano</searchLink><relatesTo>1</relatesTo> (AUTHOR) – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Magnetic+Resonance+in+Medicine%22">Magnetic Resonance in Medicine</searchLink>. Jan2025, Vol. 93 Issue 1, p341-352. 12p. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22Vibration+%28Mechanics%29%22">Vibration (Mechanics)</searchLink><br /><searchLink fieldCode="DE" term="%22Mechanical+loads%22">Mechanical loads</searchLink><br /><searchLink fieldCode="DE" term="%22Orthopedic+implants%22">Orthopedic implants</searchLink><br /><searchLink fieldCode="DE" term="%22Frequencies+of+oscillating+systems%22">Frequencies of oscillating systems</searchLink><br /><searchLink fieldCode="DE" term="%22Lorentz+force%22">Lorentz force</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: Purpose: To quantify the extent of gradient‐induced vibrations, and the magnitude of motion‐induced displacement forces ("Lenz effect"), in conductive nonmagnetic orthopedic prostheses. Methods: The investigation is carried out through numerical simulations, for a 3 T scanner. For gradient‐induced torques and vibrations, a knee and a shoulder implant are considered, at dB/dt equal to 42 T/s (rms). For motion‐induced forces associated with the Lenz effect, a knee and a hip implant are studied, considering a patient who translates on the examination couch, or walks next to it. Results: Gradient‐induced torques may be within the same order of magnitude as the worst case gravitational torque defined in the ASTM standards. However, for all investigated cases, they result to be lower. In vacuum, the extent of the corresponding vibration reduces with frequency. At the lowest investigated frequency (270 Hz), it keeps below 25 μm. For an implant partially embedded in bone, the extent of the vibration increases with frequency. Nevertheless, the displacement is far lower than the worst case observed in vacuum (negligible in contact with the bone; ˜1 μm or less where the implant emerges from the bone). The Lenz effect induced by the motion of the patient through the stationary magnetic field produces forces on the order of a few millinewtons (i.e., at least two orders of magnitude lower than the implant weight). Conclusion: Comparing the results with mechanical loads caused by ordinary activities of daily living, and with the levels of tolerable micromotions, a good safety margin is confirmed. [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of Magnetic Resonance in Medicine is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=180521859 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1002/mrm.30263 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 12 StartPage: 341 Subjects: – SubjectFull: Vibration (Mechanics) Type: general – SubjectFull: Mechanical loads Type: general – SubjectFull: Orthopedic implants Type: general – SubjectFull: Frequencies of oscillating systems Type: general – SubjectFull: Lorentz force Type: general Titles: – TitleFull: Gradient‐induced vibrations and motion‐induced Lenz effects on conductive nonmagnetic orthopedic implants in MRI. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Zilberti, Luca – PersonEntity: Name: NameFull: Curreli, Cristina – PersonEntity: Name: NameFull: Arduino, Alessandro – PersonEntity: Name: NameFull: Zanovello, Umberto – PersonEntity: Name: NameFull: Baruffaldi, Fabio – PersonEntity: Name: NameFull: Bottauscio, Oriano IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 01 Text: Jan2025 Type: published Y: 2025 Identifiers: – Type: issn-print Value: 07403194 Numbering: – Type: volume Value: 93 – Type: issue Value: 1 Titles: – TitleFull: Magnetic Resonance in Medicine Type: main |
| ResultId | 1 |