Feasibility of virtual non-iodine coronary calcium scoring on dual source photon-counting coronary CT angiography: a dynamic phantom study.
Saved in:
| Title: | Feasibility of virtual non-iodine coronary calcium scoring on dual source photon-counting coronary CT angiography: a dynamic phantom study. |
|---|---|
| Authors: | Dobrolinska, Magdalena M.1,2 (AUTHOR) magdalena.dobrolinska@gmail.com, Koetzier, Lennart R.1,3 (AUTHOR), Greuter, Marcel J. W.4 (AUTHOR), Vliegenthart, Rozemarijn4 (AUTHOR), van der Bie, Judith1 (AUTHOR), Prakken, Niek H. J.4 (AUTHOR), Slart, Riemer H. J. A.2 (AUTHOR), Leiner, Tim5 (AUTHOR), Budde, Ricardo P. J.1 (AUTHOR), Mastrodicasa, Domenico3 (AUTHOR), Booij, Ronald1 (AUTHOR), Fleischmann, Dominik3 (AUTHOR), Willemink, Martin J.3 (AUTHOR), van Straten, Marcel1 (AUTHOR), van der Werf, Niels R.1 (AUTHOR) |
| Source: | European Radiology. Nov2024, Vol. 34 Issue 11, p7429-7437. 9p. |
| Subjects: | Coronary artery calcification, Computed tomography, Photon counting, Imaging phantoms, Coronary arteries |
| Abstract: | Background: The aim of our current systematic dynamic phantom study was first, to optimize reconstruction parameters of coronary CTA (CCTA) acquired on photon counting CT (PCCT) for coronary artery calcium (CAC) scoring, and second, to assess the feasibility of calculating CAC scores from CCTA, in comparison to reference calcium scoring CT (CSCT) scans. Methods: In this phantom study, an artificial coronary artery was translated at velocities corresponding to 0, < 60, and 60–75 beats per minute (bpm) within an anthropomorphic phantom. The density of calcifications was 100 (very low), 200 (low), 400 (medium), and 800 (high) mgHA/cm3, respectively. CCTA was reconstructed with the following parameters: virtual non-iodine (VNI), with and without iterative reconstruction (QIR level 2, QIR off, respectively); kernels Qr36 and Qr44f; slice thickness/increment 3.0/1.5 mm and 0.4/0.2 mm. The agreement in risk group classification between CACCCTA and CACCSCT scoring was measured using Cohen weighted linear κ with 95% CI. Results: For CCTA reconstructed with 0.4 mm slice thickness, calcium detectability was perfect (100%). At < 60 bpm, CACCCTA of low, and medium density calcification was underestimated by 53%, and 15%, respectively. However, CACCCTA was not significantly different from CACCSCT of very low, and high-density calcifications. The best risk agreement was achieved when CCTA was reconstructed with QIR off, Qr44f, and 0.4 mm slice thickness (κ = 0.762, 95% CI 0.671–0.853). Conclusion: In this dynamic phantom study, the detection of calcifications with different densities was excellent with CCTA on PCCT using thin-slice VNI reconstruction. Agatston scores were underestimated compared to CSCT but agreement in risk classification was substantial. Clinical relevance statement: Photon counting CT may enable the implementation of coronary artery calcium scoring from coronary CTA in daily clinical practice. Key Points: Photon-counting CTA allows for excellent detectability of low-density calcifications at all heart rates. Coronary artery calcium scoring from coronary CTA acquired on photon counting CT is feasible, although improvement is needed. Adoption of the standard acquisition and reconstruction protocol for calcium scoring is needed for improved quantification of coronary artery calcium to fully employ the potential of photon counting CT. [ABSTRACT FROM AUTHOR] |
| Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
|
Full text is not displayed to guests.
Login for full access.
|
|
| FullText | Links: – Type: pdflink Text: Availability: 1 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 180550109 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Feasibility of virtual non-iodine coronary calcium scoring on dual source photon-counting coronary CT angiography: a dynamic phantom study. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Dobrolinska%2C+Magdalena+M%2E%22">Dobrolinska, Magdalena M.</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)<i> magdalena.dobrolinska@gmail.com</i><br /><searchLink fieldCode="AR" term="%22Koetzier%2C+Lennart+R%2E%22">Koetzier, Lennart R.</searchLink><relatesTo>1,3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Greuter%2C+Marcel+J%2E+W%2E%22">Greuter, Marcel J. W.</searchLink><relatesTo>4</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Vliegenthart%2C+Rozemarijn%22">Vliegenthart, Rozemarijn</searchLink><relatesTo>4</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22van+der+Bie%2C+Judith%22">van der Bie, Judith</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Prakken%2C+Niek+H%2E+J%2E%22">Prakken, Niek H. J.</searchLink><relatesTo>4</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Slart%2C+Riemer+H%2E+J%2E+A%2E%22">Slart, Riemer H. J. A.</searchLink><relatesTo>2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Leiner%2C+Tim%22">Leiner, Tim</searchLink><relatesTo>5</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Budde%2C+Ricardo+P%2E+J%2E%22">Budde, Ricardo P. J.</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Mastrodicasa%2C+Domenico%22">Mastrodicasa, Domenico</searchLink><relatesTo>3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Booij%2C+Ronald%22">Booij, Ronald</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Fleischmann%2C+Dominik%22">Fleischmann, Dominik</searchLink><relatesTo>3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Willemink%2C+Martin+J%2E%22">Willemink, Martin J.</searchLink><relatesTo>3</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22van+Straten%2C+Marcel%22">van Straten, Marcel</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22van+der+Werf%2C+Niels+R%2E%22">van der Werf, Niels R.</searchLink><relatesTo>1</relatesTo> (AUTHOR) – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22European+Radiology%22">European Radiology</searchLink>. Nov2024, Vol. 34 Issue 11, p7429-7437. 9p. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22Coronary+artery+calcification%22">Coronary artery calcification</searchLink><br /><searchLink fieldCode="DE" term="%22Computed+tomography%22">Computed tomography</searchLink><br /><searchLink fieldCode="DE" term="%22Photon+counting%22">Photon counting</searchLink><br /><searchLink fieldCode="DE" term="%22Imaging+phantoms%22">Imaging phantoms</searchLink><br /><searchLink fieldCode="DE" term="%22Coronary+arteries%22">Coronary arteries</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: Background: The aim of our current systematic dynamic phantom study was first, to optimize reconstruction parameters of coronary CTA (CCTA) acquired on photon counting CT (PCCT) for coronary artery calcium (CAC) scoring, and second, to assess the feasibility of calculating CAC scores from CCTA, in comparison to reference calcium scoring CT (CSCT) scans. Methods: In this phantom study, an artificial coronary artery was translated at velocities corresponding to 0, < 60, and 60–75 beats per minute (bpm) within an anthropomorphic phantom. The density of calcifications was 100 (very low), 200 (low), 400 (medium), and 800 (high) mgHA/cm3, respectively. CCTA was reconstructed with the following parameters: virtual non-iodine (VNI), with and without iterative reconstruction (QIR level 2, QIR off, respectively); kernels Qr36 and Qr44f; slice thickness/increment 3.0/1.5 mm and 0.4/0.2 mm. The agreement in risk group classification between CACCCTA and CACCSCT scoring was measured using Cohen weighted linear κ with 95% CI. Results: For CCTA reconstructed with 0.4 mm slice thickness, calcium detectability was perfect (100%). At < 60 bpm, CACCCTA of low, and medium density calcification was underestimated by 53%, and 15%, respectively. However, CACCCTA was not significantly different from CACCSCT of very low, and high-density calcifications. The best risk agreement was achieved when CCTA was reconstructed with QIR off, Qr44f, and 0.4 mm slice thickness (κ = 0.762, 95% CI 0.671–0.853). Conclusion: In this dynamic phantom study, the detection of calcifications with different densities was excellent with CCTA on PCCT using thin-slice VNI reconstruction. Agatston scores were underestimated compared to CSCT but agreement in risk classification was substantial. Clinical relevance statement: Photon counting CT may enable the implementation of coronary artery calcium scoring from coronary CTA in daily clinical practice. Key Points: Photon-counting CTA allows for excellent detectability of low-density calcifications at all heart rates. Coronary artery calcium scoring from coronary CTA acquired on photon counting CT is feasible, although improvement is needed. Adoption of the standard acquisition and reconstruction protocol for calcium scoring is needed for improved quantification of coronary artery calcium to fully employ the potential of photon counting CT. [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=180550109 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1007/s00330-024-10806-4 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 9 StartPage: 7429 Subjects: – SubjectFull: Coronary artery calcification Type: general – SubjectFull: Computed tomography Type: general – SubjectFull: Photon counting Type: general – SubjectFull: Imaging phantoms Type: general – SubjectFull: Coronary arteries Type: general Titles: – TitleFull: Feasibility of virtual non-iodine coronary calcium scoring on dual source photon-counting coronary CT angiography: a dynamic phantom study. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Dobrolinska, Magdalena M. – PersonEntity: Name: NameFull: Koetzier, Lennart R. – PersonEntity: Name: NameFull: Greuter, Marcel J. W. – PersonEntity: Name: NameFull: Vliegenthart, Rozemarijn – PersonEntity: Name: NameFull: van der Bie, Judith – PersonEntity: Name: NameFull: Prakken, Niek H. J. – PersonEntity: Name: NameFull: Slart, Riemer H. J. A. – PersonEntity: Name: NameFull: Leiner, Tim – PersonEntity: Name: NameFull: Budde, Ricardo P. J. – PersonEntity: Name: NameFull: Mastrodicasa, Domenico – PersonEntity: Name: NameFull: Booij, Ronald – PersonEntity: Name: NameFull: Fleischmann, Dominik – PersonEntity: Name: NameFull: Willemink, Martin J. – PersonEntity: Name: NameFull: van Straten, Marcel – PersonEntity: Name: NameFull: van der Werf, Niels R. IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 11 Text: Nov2024 Type: published Y: 2024 Identifiers: – Type: issn-print Value: 09387994 Numbering: – Type: volume Value: 34 – Type: issue Value: 11 Titles: – TitleFull: European Radiology Type: main |
| ResultId | 1 |