Design and Performance Analysis of Windings Considering High Frequency Loss and Connection Mode of a Starter Generator.

Saved in:
Bibliographic Details
Title: Design and Performance Analysis of Windings Considering High Frequency Loss and Connection Mode of a Starter Generator.
Authors: Ren, Xiaojun1 (AUTHOR) g20208517@xs.ustb.edu.cn, Chen, Zhikai1 (AUTHOR), Du, Rui1 (AUTHOR), Feng, Ming1 (AUTHOR)
Source: Energies (19961073). Oct2024, Vol. 17 Issue 20, p5124. 12p.
Subjects: Skin effect, Power density, Prototypes
Abstract: The starter generator is the key component of the aircraft's starter generation system. A high power density, efficiency, and reliability are essential for an aircraft's starter generator. The configuration of the windings is closely related to the performance of the starter generator. In this paper, the winding performance analysis and design are studied. Considering the skin effect, circulation effect, and proximity effect, a calculation model of winding loss under high-frequency operation is established. The motor performance under different winding connections is compared. Through a comprehensive comparison of starting performance, generation loss, and process performance differences, the optimum configuration of windings is identified. The performance of the starter generator including winding resistance, current, and no-load loss was tested on the prototype platform to verify the rationality and correctness of the analysis and design methods. [ABSTRACT FROM AUTHOR]
Copyright of Energies (19961073) is the property of MDPI and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Full text is not displayed to guests.
FullText Links:
  – Type: pdflink
Text:
  Availability: 1
Header DbId: egs
DbLabel: Engineering Source
An: 180557863
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Design and Performance Analysis of Windings Considering High Frequency Loss and Connection Mode of a Starter Generator.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Ren%2C+Xiaojun%22">Ren, Xiaojun</searchLink><relatesTo>1</relatesTo> (AUTHOR)<i> g20208517@xs.ustb.edu.cn</i><br /><searchLink fieldCode="AR" term="%22Chen%2C+Zhikai%22">Chen, Zhikai</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Du%2C+Rui%22">Du, Rui</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Feng%2C+Ming%22">Feng, Ming</searchLink><relatesTo>1</relatesTo> (AUTHOR)
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Energies+%2819961073%29%22">Energies (19961073)</searchLink>. Oct2024, Vol. 17 Issue 20, p5124. 12p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Skin+effect%22">Skin effect</searchLink><br /><searchLink fieldCode="DE" term="%22Power+density%22">Power density</searchLink><br /><searchLink fieldCode="DE" term="%22Prototypes%22">Prototypes</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: The starter generator is the key component of the aircraft's starter generation system. A high power density, efficiency, and reliability are essential for an aircraft's starter generator. The configuration of the windings is closely related to the performance of the starter generator. In this paper, the winding performance analysis and design are studied. Considering the skin effect, circulation effect, and proximity effect, a calculation model of winding loss under high-frequency operation is established. The motor performance under different winding connections is compared. Through a comprehensive comparison of starting performance, generation loss, and process performance differences, the optimum configuration of windings is identified. The performance of the starter generator including winding resistance, current, and no-load loss was tested on the prototype platform to verify the rationality and correctness of the analysis and design methods. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Energies (19961073) is the property of MDPI and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=180557863
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.3390/en17205124
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 12
        StartPage: 5124
    Subjects:
      – SubjectFull: Skin effect
        Type: general
      – SubjectFull: Power density
        Type: general
      – SubjectFull: Prototypes
        Type: general
    Titles:
      – TitleFull: Design and Performance Analysis of Windings Considering High Frequency Loss and Connection Mode of a Starter Generator.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Ren, Xiaojun
      – PersonEntity:
          Name:
            NameFull: Chen, Zhikai
      – PersonEntity:
          Name:
            NameFull: Du, Rui
      – PersonEntity:
          Name:
            NameFull: Feng, Ming
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 15
              M: 10
              Text: Oct2024
              Type: published
              Y: 2024
          Identifiers:
            – Type: issn-print
              Value: 19961073
          Numbering:
            – Type: volume
              Value: 17
            – Type: issue
              Value: 20
          Titles:
            – TitleFull: Energies (19961073)
              Type: main
ResultId 1