ON SMOKE DETECTOR SITING ON A BEAMED CEILING.
Saved in:
| Title: | ON SMOKE DETECTOR SITING ON A BEAMED CEILING. |
|---|---|
| Authors: | Ristić, Dejan1, Blagojević, Milan1 milan.blagojevic@znrfak.ni.ac.rs, Jevtić, Radoje1, Stanković, Vladimir2 |
| Source: | Transactions of FAMENA. 2024, Vol. 48 Issue 4, p103-113. 11p. |
| Subjects: | Construction slabs, Ceilings, Fire detectors, Detectors, Aesthetics, Designers |
| Abstract: | The siting of smoke detectors in fire compartments with ceiling irregularities is one of the problems faced by designers of fire detection systems. This is due to differences or lack of rules within standards pertaining to planning and design of fire detection systems. Concealed spaces formed by beams and joists affect stratification and, consequently, the response of smoke detectors. It is crucial to detect fire as quickly as possible, so the location of a smoke detector beneath the beams or on a structural slab in the cells in-between is not a matter of aesthetics. In most standards used in the world, there are no unique regulations for smoke detector siting on ceilings with parallel or cross-bracing beams or joists. Therefore, there is a problem of determining the optimal distance between detectors and the resulting problem of delayed fire detection. The European standard is mandatory for most countries in Europe, but it does not contain rules that apply to this problem. The investigation presented in this paper is based on a combination of requirements set by different standards for smoke detector siting so as to find a rule that is applicable according to the European standard. A fire compartment and beams subdividing the ceiling with dimensions that affect stratification were chosen for simulations in the Fire Dynamics Simulator (FDS). The aim of the investigation is to identify a proper location of smoke detectors in a beamed ceiling as well as the optimal distance between them. [ABSTRACT FROM AUTHOR] |
| Copyright of Transactions of FAMENA is the property of Faculty of Mechanical Engineering and Naval Architecture, University of Zegreb and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
| FullText | Links: – Type: pdflink Text: Availability: 0 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 181179819 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: ON SMOKE DETECTOR SITING ON A BEAMED CEILING. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Ristić%2C+Dejan%22">Ristić, Dejan</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Blagojević%2C+Milan%22">Blagojević, Milan</searchLink><relatesTo>1</relatesTo><i> milan.blagojevic@znrfak.ni.ac.rs</i><br /><searchLink fieldCode="AR" term="%22Jevtić%2C+Radoje%22">Jevtić, Radoje</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Stanković%2C+Vladimir%22">Stanković, Vladimir</searchLink><relatesTo>2</relatesTo> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Transactions+of+FAMENA%22">Transactions of FAMENA</searchLink>. 2024, Vol. 48 Issue 4, p103-113. 11p. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22Construction+slabs%22">Construction slabs</searchLink><br /><searchLink fieldCode="DE" term="%22Ceilings%22">Ceilings</searchLink><br /><searchLink fieldCode="DE" term="%22Fire+detectors%22">Fire detectors</searchLink><br /><searchLink fieldCode="DE" term="%22Detectors%22">Detectors</searchLink><br /><searchLink fieldCode="DE" term="%22Aesthetics%22">Aesthetics</searchLink><br /><searchLink fieldCode="DE" term="%22Designers%22">Designers</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: The siting of smoke detectors in fire compartments with ceiling irregularities is one of the problems faced by designers of fire detection systems. This is due to differences or lack of rules within standards pertaining to planning and design of fire detection systems. Concealed spaces formed by beams and joists affect stratification and, consequently, the response of smoke detectors. It is crucial to detect fire as quickly as possible, so the location of a smoke detector beneath the beams or on a structural slab in the cells in-between is not a matter of aesthetics. In most standards used in the world, there are no unique regulations for smoke detector siting on ceilings with parallel or cross-bracing beams or joists. Therefore, there is a problem of determining the optimal distance between detectors and the resulting problem of delayed fire detection. The European standard is mandatory for most countries in Europe, but it does not contain rules that apply to this problem. The investigation presented in this paper is based on a combination of requirements set by different standards for smoke detector siting so as to find a rule that is applicable according to the European standard. A fire compartment and beams subdividing the ceiling with dimensions that affect stratification were chosen for simulations in the Fire Dynamics Simulator (FDS). The aim of the investigation is to identify a proper location of smoke detectors in a beamed ceiling as well as the optimal distance between them. [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of Transactions of FAMENA is the property of Faculty of Mechanical Engineering and Naval Architecture, University of Zegreb and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=181179819 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.21278/TOF.484044722 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 11 StartPage: 103 Subjects: – SubjectFull: Construction slabs Type: general – SubjectFull: Ceilings Type: general – SubjectFull: Fire detectors Type: general – SubjectFull: Detectors Type: general – SubjectFull: Aesthetics Type: general – SubjectFull: Designers Type: general Titles: – TitleFull: ON SMOKE DETECTOR SITING ON A BEAMED CEILING. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Ristić, Dejan – PersonEntity: Name: NameFull: Blagojević, Milan – PersonEntity: Name: NameFull: Jevtić, Radoje – PersonEntity: Name: NameFull: Stanković, Vladimir IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 10 Text: 2024 Type: published Y: 2024 Identifiers: – Type: issn-print Value: 13331124 Numbering: – Type: volume Value: 48 – Type: issue Value: 4 Titles: – TitleFull: Transactions of FAMENA Type: main |
| ResultId | 1 |